• 제목/요약/키워드: flowing amount

검색결과 210건 처리시간 0.025초

지속가능한 발전을 위한 환경용량의 산정과 토지이용형태 연구 - 수도권지역을 중심으로 - (Sustainable Land Use within a Limit of Environmental Carrying Capacity in Metropolitan Area, Korea)

  • 문태훈
    • 한국시스템다이내믹스연구
    • /
    • 제8권2호
    • /
    • pp.51-82
    • /
    • 2007
  • The purpose of this paper is exploring changes in land use pattern when considering environmental carrying capacity. A sustainable development requires a society to define sustainability constraints, environmental carrying capacity. Environmental carrying capacity can be defined as a level of human activity a region can sustain at a desired level of quality of environment. This concept of environmental carrying capacity can be applied to land use to explore sustainable land use pattern. Since land use pattern can affect environment in an important way, exploring sustainable land use pattern within the limit of environmental carrying capacity can suggest useful implications for a sustainable regional management and planning. For this purpose, this paper built the environmental carrying capacity land use model and applied it to the Metropolitan Area, Korea. System dynamics modeling methods was used to build the model. The model developed in this paper consisted of 6sectors; population, housing, industry, land, environment, and traffic sector. The model limits its main focus on the NO2 level as an indicator of quality of environment in Metropolitan Area. Box model was translated into system dynamics model and combined to urban dynamics model to estimate NO2 level, the maximum number of population, industry structure, housing and maximum amount of land use for industrial, housing, and green space that can sustain desirable NO2 level. Metropolitan area was divided into 16 areas and the model was applied to each area. Since NO2 is flowing in and out from each area, model was built to allow this transboundering nature of air pollutants. Based on the model estimation, several policy implications for a sustainable land use pattern was discussed.

  • PDF

방류수의 수위 및 유량 분석을 통한 해양 소수력 성능평가 (Performance Evaluation of Ocean Small Hydropower Plant by Analyzing Water Level and Flow Rate of Circulating Water)

  • 강금석;김지영;유무성
    • 신재생에너지
    • /
    • 제5권3호
    • /
    • pp.32-39
    • /
    • 2009
  • The Samcheonpo ocean small hydropower plant (SHP) has a special feature of using marginal hydraulic head of circulating water system of fossil fuel power plant as a power source and having the characteristics of general hydropower generation and tidal power generation as well. Also, it contributes to reducing green house gases and developing clean energy source by recycling circulating water energy otherwise dissipated into the ocean. The efficiency of small hydropower plant is directly affected by effective head and flow rate of discharged water. Therefore, the efficiency characteristics of ocean hydropower plant are analyzed with the variation of water level and flow rate of discharged water, which is based on the accumulated operation data of the Samcheonpo hydropower plant. After the start of small hydropower plant operation, definite rise of water level was observed. As a result of flow pattern change from free flow to submerged flow, the instability of water surface in overall open channel is increased but it doesn't reach the extent of overflowing channel or having an effect on circulation system. Performance evaluation result shows that the generating power and efficiency of small hydropower exceeds design requirements in all conditions. Analysis results of CWP's water flow rate verify that the amount of flowing water is measured less and the highest efficiency of small hydropower plant is achieved when the effective head has its maximum value. In conclusion, efficiency curve derived from water flow rate considering tidal level shows the best fitting result with design criteria curve and it is verified that overall efficiency of hydropower system is satisfactory.

  • PDF

통합연료필터의 저온유동성 시험장치 핵심기술개발 (Core Technology Development of Low Temperature Fluidity Test System with Composited Fuel Filter)

  • 윤석창;조상;윤달환
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.420-426
    • /
    • 2014
  • 본 연구에서는 저온유동성 성능검사 시스템 구현을 통해 디젤 차량용 통합형 연료필터의 성능을 평가한다. 저온유동성시험 장치의 시험조건은 경유(또는 등유)를 사용하고, 상온, -20 및 $-30^{\circ}C$ 에서 경유공급압력 $3.4kgf/cm^2$, 연료공급량 60 l/H, 설정전류 30 A 및 전압은 $13V_{dc}$를 사용한다. 시료시험으로 통합필터를 지그에 장착하고, 경유(또는 등유)를 일정압력과 유량으로 설정하여 챔버 탱크와 필터에 채운 후, 설정시간 동안 설정온도로 냉각한 후, 필터 전후에 따라 유압과 시동시간, 히터의 소모전류 및 전력을 측정한다.

부하 전류가 케이블의 수명에 미치는 영향에 대한 연구 (A study on the Effects of Load Current for Lifetime of Cable Systems)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권4호
    • /
    • pp.205-209
    • /
    • 2015
  • 발전소에서 설치 운영 중이 전력 케이블 시스템에서 사고가 발생함으로써 초래되는 경제적 손실은 매우 클 뿐만이 아니라, 원상 복구하는 데 많은 시간과 비용이 필요하다. 이를 대비하기 위하여 사고를 예측하고 방지하는 기술이 필요하다. 우리는 발전소에서 운전 중인 케이블의 절연 저항을 측정하기 위하여 부하 전류와 온도와의 상관 관계를 확인 하였고, 진단 데이터를 분석 평가함으로써 케이블 시스템의 열화 상태를 파악하여 사고가 발생하기 전에 케이블 교체를 할 수 시기를 예측하게 하였다. 이 논문에서 우리는 운전 중인 6.6 kV 케이블에서 부하 전류가 수명에 미치는 영향에 대하여 연구한 결과를 소개한다. 케이블의 부하에 전류가 흐르면, 도체에 열이 발생하게 되고 케이블의 수명이 감소된다. 케이블의 부하 전류가 수명에 미치는 영향을 파악하기 위하여 수명 이론을 적용함으로써 절연저항 및 전류 측정 장치를 개발하여 운전 중인 케이블에 설치하였다.

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study

  • Kim, Jae-Hyung;Shin, Beum-Joo;Baik, Seung-Wan;Jeon, Gye-Rok
    • 센서학회지
    • /
    • 제26권1호
    • /
    • pp.15-23
    • /
    • 2017
  • In this study, bioelectrical impedance analysis, which has been used to assess an alteration in intracellular fluid (ICF) of the body, was applied to detect intravenous infiltration. The experimental results are described as follows. Firstly, when infiltration occurred, the resistance gradually decreased with time and frequency i.e., the resistance decreased with increasing time, proportional to the amount of infiltrated intravenous (IV) solution. At each frequency, the resistance gradually decreased with time, indicating the IV solution (also blood) accumulated in the extracellular fluid (ECF) (including interstitial fluid). Secondly, the resistance ratio started to increase at infiltration, showing the highest value after 1.4 min of infiltration, and gradually decreased thereafter. Thirdly, the impedance ($Z_C$) of cell membrane decreased significantly (especially at 50 kHz) during infiltration and gradually decreased thereafter. Fourthly, Cole-Cole plot indicated that the positions of (R, $X_C$) shifted toward left owing to infiltration, reflecting the IV solution accumulated in the ECF. The resistance ($R_0$) at zero frequency decreased continuously over time, indicating that it is a vital impedance parameter capable of detecting early infiltration during IV infusion. Finally, the mechanism of the current flowing through the ECF, cell membrane, and ICF in the subcutaneous tissues was analyzed as a function of time before and after infiltration, using an equivalent circuit model of the human cell. In conclusion, it was confirmed that the infiltration could be detected early using these impedance parameters during the infusion of IV solution.

소양호 상류유역의 비점오염원 유출특성에 의한 원단위 산정 (Estimation of the Unit Load by the Outflow Characteristics of Non-Point Source Pollution in the Upstream Watershed of So-yang Lake)

  • 최한규;박수진;김진수
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.37-46
    • /
    • 2005
  • From 2000 to 2004, the research was carried out at Naerin-cheon and Inbook-cheon, the upper streams of Soyang Lake, to study the relationship between precipitation and eutrophication-causing water pollutants, BOD, T-N and T-P. During the five years, the amount of flowing water was measured, and the water quantity was examined under different precipitation levels. From the observation, outflow patterns of the water pollutants and changes in the water quality factors at the time of rainfall were clarified. In addition, estimation of the unit load was made for each stream; for Naerin-cheon at the time of rainfall, we estimated BOD to be $1,112kg/km^2/year$, T-N to be $2,077kg/km^2/year$, and T-P to be $223kg/km^2/year$; for Inbook-cheon at the time of rainfall, we estimated BOD to be $1,229kg/km^2/year$, T-N to be $1,565kg/km^2/year$, and T-P to be $255kg/km^2/year$. For the time of no rainfall different estimation was made; for Naerin-cheon, we estimated BOD to be $2,403g/km^2/day$, T-N to be $5,004g/km^2/day$, and T-P to be $53g/km^2/day$; and for Inbook-cheon, we estimated BOD to be $1,550g/km^2/day$, T-N to be $2,283g/km^2/day$, and T-P to be $42g/km^2/day$.

  • PDF

Energy Efficiency of Fluidized Bed Drying for Wood Particles

  • Park, Yonggun;Chang, Yoon-Seong;Park, Jun-Ho;Yang, Sang-Yun;Chung, Hyunwoo;Jang, Soo-Kyeong;Choi, In-Gyu;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권6호
    • /
    • pp.821-827
    • /
    • 2016
  • This study evaluates the economic feasibility of industrializing fluidized bed dryer for wood particles. The theoretically required heat energy and energy efficiency were evaluated using a pilot scale fluidized bed dryer. When Mongolian Oak wood particles with 50% initial moisture content were dried in the fluidized bed dryer with air of $70^{\circ}C$ air circulating at 1.1-1.3 m/s for 30 minutes, the total theoretically required heat energy was 2,177 kJ. Of this, 1,763 kJ (approximately 81.0%) was used to heat the air flowing in from outside the dryer and 386 kJ (approximately 17.7%) was used to heat and remove water from the wood particles. Actual energy consumed was 7,560 kJ, giving energy efficiency of 28.8%. Thus, to industrialize a drying method such as fluidized bed drying, where the dryer volume is significantly larger than the volume of wood particles, it is necessary to minimize energy loss and maximize energy efficiency by designing the dryer size considering the amount of wood particles and choosing a suitable air circulation rate.

공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구 (An Experimental Study on Frost Generation Mechanism from Evaporator Tube in Air Conditioning System)

  • 박상균;오철
    • 한국항해항만학회지
    • /
    • 제30권1호
    • /
    • pp.113-117
    • /
    • 2006
  • 이 실험의 목적은 튜브형 증발관에서 입구 공기 속도, 온도와 상대 습도에 따른 서리층 생성의 비교 검토에 있다. 입구 공기 속도와 온도는 각각 $0.3^m/_s,\;0.6^m/_s,\;0.9^m/_s,\;15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C$로 하였고, 상대 습도는 $70\%\~90\%$로 하였다. 그리고 일반적인 공조기용 열교환기에서의 서리발생 현상을 파악하기 위하여 냉각튜브의 온도를 $-15^{\circ}C$로 일정하게 유지하였다. 그 결과 공급공기의 상대습도, 유속 및 온도가 증가할수록 서리 생성량이 증가함을 알 수 있었다.

Effects of the Sintering Atmosphere and Ni Content on the Liquid-phase Sintering of $TiB_2$-Ni

  • Suk-Joong L. Kang;Baung, Jin-Chul;Park, Yeon-Gyu;Kang, Eul-Son;Baek, Yong-Kee;Jung, Sug-Woo
    • 한국세라믹학회지
    • /
    • 제38권3호
    • /
    • pp.207-211
    • /
    • 2001
  • The effects of the sintering atmosphere and Ni content on t도 densification of TiB$_2$-Ni have been investigated. TiB$_2$powder compacts containing 10, 20, and 30 wt% Ni were liquid-phase sintered at 1500-1$700^{\circ}C$ in vacuum or in flowing Ar. The densification was enhanced as Ni content increased. For a given Ni content, the densification was faster in compacts in compacts with larger grain size. These densification behaviors agree well with the prediction of the recently developed pore-filling theory. For samples containing high Ni contents, 80TiB$_2$-20Ni and 70TiB$_2$-30Ni, the densification was faster in vacuum than in Ar. In particular, 70TiB$_2$-30Ni was fully densified at 1$700^{\circ}C$ for 60min in vacuum. The suppressed densification in Ar was due to the entrapped Ar in the isolated pores. On the other hand, for 90TiB$_2$-10Ni, the Ar-sintering resulted in higher densification than did the vacuum-sintering. This result was attributed to the suppression of Ni volatilization by the Ar in the furnace and a retarded isolation of pores due to the limited amount of liquid in the sample. Therefore, vacuum sintering is recommended for the preparation of TiB$_2$-Ni with a high Ni content while Ar sintering is recommended for the preparation of TiB$_2$-Ni with a low Ni content.

  • PDF

소셜 네트워크 환경에서 변형된 TF-IDF를 이용한 핫 토픽 예측 기법 (Hot Topic Prediction Scheme Using Modified TF-IDF in Social Network Environments)

  • 노연우;임종태;복경수;유재수
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제23권4호
    • /
    • pp.217-225
    • /
    • 2017
  • 최근 실시간으로 생성되는 대용량의 SNS 데이터로부터 유의미한 정보를 찾아내고 분석하는 것이 중요해지면서 핫 토픽 예측에 대한 관심도 크게 증가하고 있다. 기존 핫 토픽 검출 기법은 시간적 속성을 고려하지 않기 때문에 빠르게 변화하는 사회에서 이슈화되는 핫 토픽을 예측하기에는 부적합하다. 본 논문에서는 소셜 네트워크 환경에서 변형된 TF-IDF를 통한 핫 토픽 예측 기법을 제안한다. 변형된 TF-IDF을 이용하여 과거의 IDF 값에 대한 현재의 IDF값의 비율로 순간적으로 이슈화되는 후보 키워드 집합을 추출한다. 추출된 후보 키워드에 사용자의 영향력과 전문성을 고려한 가중치를 부여하여 핫 토픽예측 지수를 계산한다. 제안하는 기법의 우수성을 보이기 위해 기존의 핫 토픽 검출 기법과의 성능평가를 수행한다. 또한 제안하는 기법이 핫 토픽을 정확히 예측하는지를 보이기 위해 네이버 한글 뉴스 기사를 통한 핫 토픽 예측 기법의 질을 평가한다.