• Title/Summary/Keyword: flowing amount

Search Result 210, Processing Time 0.028 seconds

A Study on Heat and Mass Transfer Characteristics of LiBr-$H_2$O Solution with a Sufactant Flowing over a Cooled Horizontal Tube (계면활성제 첨가시 수평 냉각관 외부를 흘러내리는 LiBr수용액의 열 및 물질전달 특성에 관한 연구)

  • 김경희;설신수;이상용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.341-349
    • /
    • 2002
  • Heat and mass transfer characteristics of a surfactant-added LiBr-$H_2O$ solution flowing over a single horizontal tube were examined experimentally. The parameters considered were surfactant (2-ethyl-1-hexanol) concentration, solution temperature at the top of the tube and absorber pressure. Even with an amount of the surfactant below the solubility limit, heat and mass transfer performances were enhanced tremendously. The Nusselt and Sherwood numbers increased by about 70% and 340%, respectively, when 10 ppm of the surfactant was added. However, an excess amount of the surfactant in the solution did not bring a further enhancement. The absorption performance deteriorated when the non-condensable gases were extracted from the system (by a vacuum pump) since the vaporized surfactant was also extracted during the process. Therefore, it is desirable to add a sufficient amount of the surfactant (more than 10 ppm) to maintain high performance of absorption.

Changes in the Amount of PEG Free-Flowing Back from PEG-Treated Waterlogged Archaeological Wood and the Compressive Strength According to Relative Humidity Conditions (습도조건에 따른 PEG 처리 수침고목재의 PEG 용출량 및 압축강도 변화)

  • Jo, Ah Hyeon;Lee, Kwang-Hee;Choi, Tae-Ho;Go, In Hee;Seo, Jeong-Wook
    • Journal of Conservation Science
    • /
    • v.36 no.3
    • /
    • pp.225-235
    • /
    • 2020
  • The present study aimed to monitor changes in the amount of PEG free-flowing back from PEG-treated woods and compressive strength changes with change in relative humidity from 90% to 30%. The change in the relative humidity was done 3 times. For the current study, water-logged wood (Prinus group) was used and the wooden blocks cut out of it were subjected to 3 different impregnation methods combined with different drying conditions as follows: 1) impregnating with 80% PEG#4000 followed by drying in nature (hereafter PEG80), 2) impregnating with 40% PEG#4000 and then drying in vacuum freeze drying equipment (hereafter PEG40), and 3) impregnating with 40% PEG#4000 in t-butanol, followed by drying in the vacuum freeze drying equipment (hereafter TB40). It was verified that most of the PEG was free-flowing back from the PEG-treated woods; however, a small amount of left PEG was observed on the lumen surface. The amount of PEG free-flowing back from the PEG-treated woods increased whenever the relative humidity changes from 90% to 30%. The compressive strengths of PEG80 and TB40 were increased whenever the relative humidity changed from 90% to 30%, whereas PEG40 decreased. The current study showed how to control the relative humidity to effectively manage PEG-treated waterlogged woods.

The Execution and Estimation of Construction Cost of High Fluidity Concrete Applying Flowing Concrete Method (유동화공법에 의해 제조한 고유동 콘크리트의 시공 및 원가분석)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.129-136
    • /
    • 2004
  • High fluidity concrete(HFC) requires high dosage of superplasticizer to acquire sufficient fluidity, and high contents of fine powder and viscosity enhancing admixtures to resist segregation. The use of high amount of admixtures to make HFC at batcher plant in ready mixed concrete company is one of the reasons to raise the manufacturing cost of HFC. For this reason, new type of manufacturing method of HFC are described using both flowing concrete method and segregation reducing superplasticizer(SRS) in order to gain economical profit and offer the convenience for quality control.. As dosage of melamine based superplasticizer increases, it shows that fluidity and bleeding increase, while air contents and ratio of segregation resistance decrease. It also shows that addition of viscosity agent into superplasticizer reduce bleeding and improve segregation resistance of concrete. Dosage of AE agent into superplasticizer containing viscosity agent recovers loss of air contents during flowing procedure. Combination of proper contents of superplasticizer, viscosity agent and AE agent make possible to develope segregation reducing type superplasticizer. Compressive strength of high fluidity concrete applying flowing method with it is higher than that of base concrete. No differences of compressive strength between compacting methods are found. For the estimation of construction cost of high fluidity concreting using segregation reducing type superplasicizer, under same strength levels, although material cost of high fluidity concrete is somewhat higher than that of plain concrete due to segregation reducing type superplasticizer cost, labor cost and equipment cost of high fluidity concrete is cheaper than that of plain concrete. However, based on the strength differences, high fluidity concrete shows lower material cost, labor cost and equipment cost than that of plain concrete due to decreasing in size of member and re-bar caused by high strength development of concrete.

Properties of Hydration Heat with Compressive Strength Level of High Flowing Self-Compacting Concrete (고유동 자기충전 콘크리트의 압축강도 수준에 따른 수화발열 특성)

  • Choi, Yun Wang;Jung, Jea Gwone;Lee, Jae Nam;Kim, Byoung Kwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.531-541
    • /
    • 2009
  • The research analyzes and investigates conventional concrete, hydration heat, set, and mechanical properties by making high flowing self-compacting concretes of binary blend and ternary blend as one of evaluations about the properties of the hydration heat of high flowing self-compacting concrete with a strength of 30, 50, and 70 MPa. In addition, it estimates concrete adiabatic temperatures by calculating a thermal property value of powder obtained by measuring a heat evolution amount for powder used in concrete, a thermal property value of concrete obtained by conducting a simple adiabatic temperature test, and a normal thermal property value of material used in concrete, using a simple equation. Moreover, it analyzes and investigates the hydration heat property of high flowing self-compacting concrete and the thermal stress caused by hydration heat by conducting a 3D temperature stress analysis for the hydration heat and the adiabatic temperature obtained by temperature analysis, using MIDAS CIVIL 06 program.

A Study on the Estimation of Loss Rate of Dredged Fills (준설토의 유실률 평가에 관한 연구)

  • Kim, Hong-Taek;Kim, Seog-Yeol;Kang, In-Kyu;Park, Jae-Eock
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 2000
  • Volume change of the dredged soils is composed of loss amount of the soil particles flowing over an outflow weir with water and settlements due to both the self-weight consolidation in reclaimed layer and the desiccation at the surface of reclaimed layer. In order to estimate the amount of soil particles flowing over an outflow weir with water, the breakage theory and the results of hydrometer analyses. To verify a validity of the proposed procedure, evaluated loss ratio is compared with various estimates from the other existing methods.

  • PDF

Principle Relations Between Biomass and Production of Phytoplankton and Physicochemical Factors in Two Eutrophic Lakes of the Mediterranean Sea

  • Kim, Ki-Tai
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.227-232
    • /
    • 2004
  • Hydrological and biological studies on ecosystems of the lakes 'etang de Berre' and 'etang de Vaime', the four rivers flowing into these lakes, and the Mediterranean Sea are carried out during the whole two-year period. The phytoplankton population of the lakes 'etang de Berre' and 'etang de Vaine' is larger than that of the seawater or freshwater populations of four neighbouring rivers. This is due to the increasing nutriments such as phosphate, nitrate, and silicate flowing into the lakes from the four rivers. The superfluous phytoplanktons in the lakes flow into the Mediterranean Sea via the Caronte Canal. Phytoplanktons multiplicated by phosphate of lake 'etang de Berre' can produce 10,160 tons of assimilated carbon per year, and those multiplicated by nitrate produce 18,450 tons of assimilated carbon per year. According to Steeman Nielsen's primary production estimation, phytoplanktons produce about 45,000 tons of carbon per year through assimilation in lake'4tang de Berre' and 10,000 tons of carbon per year in lake 'etang de Vaime'. The amount of carbon produced by phytoplanktons and the amount of phosphate, and nitrate are different according to the sea, river, and estuary.

An Experimental Study on the Engineering Properties of the Three Components Middle Fluidity Concrete (3성분계 중유동 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kim, Kab-Soo;Cho, Bong-Suk;Yun, Jong-Ki;Yun, Moon-Ki;Jang, Jong-Ho;Kim, Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.9-12
    • /
    • 2003
  • High flowing concrete has not spread whole in the normal concrete structure, because it requires special quality control technique. And recently owing to the lack of natural resources and reinforcement of environmental standard, the construction cost of cement is increased rapidly. Also rem icon industry has gone through various economical difficulty as the manufacture cost of concrete is increased. So, the purpose of this study is to evaluate the qualities of middle fluidity concrete using the fly-ash and portland blast-furnace slag cement in order to decrease the amount of cement and resolve the problem of the quality control of high flowing concrete and the manufacture cost. The results of this study show that it reduce the amount of addition of superplasticizer and develope properties of concrete to the use the fly-ash and portland blast-furnace slag cement.

  • PDF

A Study on the Flowing Characteristic of Concrete with Copper Smelting Slag (동제련 슬래그를 사용한 콘크리트의 경시별 유동특성에 관한 실험적 연구)

  • 김정욱;지석원;이세현;전현규;유택동;서치호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.319-324
    • /
    • 2001
  • Recently new practical use way of industry product is required. In this study, to find flowing property of slump, unit weight, the air amount, compressive strength etc. Compressive strength 240, 270kgf/$cm^{2}$, slump 8$\pm$2.5(I), 152$\pm$.5(II)cm, mixing ratio of copper smelting slag decided by 0, 25, 50, 75, 100% gradually, The result of this study was follows ; 1. Unit weight increased 2.2%~4.4% according as mixing ratio of copper smelting slag increases. 2. Slump increased about 2~5% as the mixing ratio increased gradually 3. Compressive strength was increased about 4~28% in copper smelting slag mixing ratio 25~50% and 8~20% decreased more than mixing ratio 75%.

  • PDF

A Study on Darrieus-type Hydroturbine toward Utilization of Extra-Low Head Natural Flow Streams

  • Tanaka, Kei;Hirowatari, Kotaro;Shimokawa, Kai;Watanabe, Satoshi;Matsushita, Daisuke;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.3
    • /
    • pp.152-159
    • /
    • 2013
  • A two-dimensional Darrieus-type hydroturbine system, installed with a wear for flow streams such as small rivers and waterways, has been developed for hydropower utilization of extra-low head less than 2m. There are several problems such as flow rate change and flowing wastes to be solved for its practical use in natural flow streams. In the present study, at first, a design guideline in the case of overflow or bypass flow is shown by using simple flow model. Next, in order to avoid the unexpected obstacles flowing into the hydroturbine, an installation of waste screening system is examined. It is confirmed that the screen is effective with some amount of bypass flow rate, however the output power is remarkably deteriorated.

Light Flicker of Three-Phase AC-powered LED Lamp (3상 교류전원 LED 램프의 광 플리커)

  • Lee, Dong Won;Kim, Byungcheul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.262-267
    • /
    • 2014
  • This study describes that light flicker of LED lamp is improved by placing an AC-powered LED block in each phase of three-phase AC power. Rectified current is considered as an instantaneous luminous flux because the current flowing through the LED block is proportional to the amount of light emitted by the LED block. Percent flicker is calculated simply by modeling the rectified current flowing through the LED block to a triangular wave current. Percent flicker is 100% in single-phase AC powered LED lamp. Percent flicker of the same level as that in an incandescent lamp (6%~14%) is however, achieved if light emission starts before $40^{\circ}$ in each voltage phase of three-phase AC power.