• Title/Summary/Keyword: flowing amount

Search Result 210, Processing Time 0.022 seconds

Sustainable Land Use within a Limit of Environmental Carrying Capacity in Metropolitan Area, Korea (지속가능한 발전을 위한 환경용량의 산정과 토지이용형태 연구 - 수도권지역을 중심으로 -)

  • Moon, Tae-Hoon
    • Korean System Dynamics Review
    • /
    • v.8 no.2
    • /
    • pp.51-82
    • /
    • 2007
  • The purpose of this paper is exploring changes in land use pattern when considering environmental carrying capacity. A sustainable development requires a society to define sustainability constraints, environmental carrying capacity. Environmental carrying capacity can be defined as a level of human activity a region can sustain at a desired level of quality of environment. This concept of environmental carrying capacity can be applied to land use to explore sustainable land use pattern. Since land use pattern can affect environment in an important way, exploring sustainable land use pattern within the limit of environmental carrying capacity can suggest useful implications for a sustainable regional management and planning. For this purpose, this paper built the environmental carrying capacity land use model and applied it to the Metropolitan Area, Korea. System dynamics modeling methods was used to build the model. The model developed in this paper consisted of 6sectors; population, housing, industry, land, environment, and traffic sector. The model limits its main focus on the NO2 level as an indicator of quality of environment in Metropolitan Area. Box model was translated into system dynamics model and combined to urban dynamics model to estimate NO2 level, the maximum number of population, industry structure, housing and maximum amount of land use for industrial, housing, and green space that can sustain desirable NO2 level. Metropolitan area was divided into 16 areas and the model was applied to each area. Since NO2 is flowing in and out from each area, model was built to allow this transboundering nature of air pollutants. Based on the model estimation, several policy implications for a sustainable land use pattern was discussed.

  • PDF

Performance Evaluation of Ocean Small Hydropower Plant by Analyzing Water Level and Flow Rate of Circulating Water (방류수의 수위 및 유량 분석을 통한 해양 소수력 성능평가)

  • Kang, Keum-Seok;Kim, Ji-Young;Ryu, Moo-Sung
    • New & Renewable Energy
    • /
    • v.5 no.3
    • /
    • pp.32-39
    • /
    • 2009
  • The Samcheonpo ocean small hydropower plant (SHP) has a special feature of using marginal hydraulic head of circulating water system of fossil fuel power plant as a power source and having the characteristics of general hydropower generation and tidal power generation as well. Also, it contributes to reducing green house gases and developing clean energy source by recycling circulating water energy otherwise dissipated into the ocean. The efficiency of small hydropower plant is directly affected by effective head and flow rate of discharged water. Therefore, the efficiency characteristics of ocean hydropower plant are analyzed with the variation of water level and flow rate of discharged water, which is based on the accumulated operation data of the Samcheonpo hydropower plant. After the start of small hydropower plant operation, definite rise of water level was observed. As a result of flow pattern change from free flow to submerged flow, the instability of water surface in overall open channel is increased but it doesn't reach the extent of overflowing channel or having an effect on circulation system. Performance evaluation result shows that the generating power and efficiency of small hydropower exceeds design requirements in all conditions. Analysis results of CWP's water flow rate verify that the amount of flowing water is measured less and the highest efficiency of small hydropower plant is achieved when the effective head has its maximum value. In conclusion, efficiency curve derived from water flow rate considering tidal level shows the best fitting result with design criteria curve and it is verified that overall efficiency of hydropower system is satisfactory.

  • PDF

Core Technology Development of Low Temperature Fluidity Test System with Composited Fuel Filter (통합연료필터의 저온유동성 시험장치 핵심기술개발)

  • Yun, Suck-Chang;Zhao, Xiang;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.420-426
    • /
    • 2014
  • In this paper, we have implemented the low temperature fluidity test system with the composited fuel filter and heater, which has tested the low temperature fluidity of gasoline, an engine start time, the consumption of electricity and power to evaluate the system performance. The test condition have used the diesel fuel, the normal temperature, the diesel fuel supply pressure $3.4kgf/cm^2$ at $-20{\sim}-30^{\circ}C$, the fuel supply quantization 60 l/H, the setting current 30 A and the voltage $13V_{dc}$. In order to simulate the operation of diesel fuel filter, we will establish the composited fuel filter into test jig, and be filled with chamber tank and filter by a constant flow quantization and pressure. After these, it shall be cold for setting time. And then we have measured the consumption current and power of heater, an operating time and pressure of filter.

A study on the Effects of Load Current for Lifetime of Cable Systems (부하 전류가 케이블의 수명에 미치는 영향에 대한 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.205-209
    • /
    • 2015
  • The economic losses resulted from the accident in the power cables at the power station is not only huge but also requires a great amount of time and expenses to restore to the former condition. In order to prevent these, it is necessary to invent and apply a technique to expect and prevent the accidents. In order to measure insulation resistances of power cables in operation, we derived the relations between load current and temperature. By analyzing data obtained from our measuring equipments, we showed the expected time to change deteriorated cables before accident occurs. We present a result of our study on the effects of the load current on lifetime of 6.6 kV cable systems in operation. With the current flowing through the load of the cable a heat is generated reducing the lifetime of the cable. In order to find out the effect of load current on the lifetime of cable systems, we applied the lifetime theory to the development of two equipments to measure insulation resistance and current of cable systems in operation.

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study

  • Kim, Jae-Hyung;Shin, Beum-Joo;Baik, Seung-Wan;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2017
  • In this study, bioelectrical impedance analysis, which has been used to assess an alteration in intracellular fluid (ICF) of the body, was applied to detect intravenous infiltration. The experimental results are described as follows. Firstly, when infiltration occurred, the resistance gradually decreased with time and frequency i.e., the resistance decreased with increasing time, proportional to the amount of infiltrated intravenous (IV) solution. At each frequency, the resistance gradually decreased with time, indicating the IV solution (also blood) accumulated in the extracellular fluid (ECF) (including interstitial fluid). Secondly, the resistance ratio started to increase at infiltration, showing the highest value after 1.4 min of infiltration, and gradually decreased thereafter. Thirdly, the impedance ($Z_C$) of cell membrane decreased significantly (especially at 50 kHz) during infiltration and gradually decreased thereafter. Fourthly, Cole-Cole plot indicated that the positions of (R, $X_C$) shifted toward left owing to infiltration, reflecting the IV solution accumulated in the ECF. The resistance ($R_0$) at zero frequency decreased continuously over time, indicating that it is a vital impedance parameter capable of detecting early infiltration during IV infusion. Finally, the mechanism of the current flowing through the ECF, cell membrane, and ICF in the subcutaneous tissues was analyzed as a function of time before and after infiltration, using an equivalent circuit model of the human cell. In conclusion, it was confirmed that the infiltration could be detected early using these impedance parameters during the infusion of IV solution.

Estimation of the Unit Load by the Outflow Characteristics of Non-Point Source Pollution in the Upstream Watershed of So-yang Lake (소양호 상류유역의 비점오염원 유출특성에 의한 원단위 산정)

  • Choi, Han-Kuy;Park, Soo-Jin;Kim, Jin-Soo
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.37-46
    • /
    • 2005
  • From 2000 to 2004, the research was carried out at Naerin-cheon and Inbook-cheon, the upper streams of Soyang Lake, to study the relationship between precipitation and eutrophication-causing water pollutants, BOD, T-N and T-P. During the five years, the amount of flowing water was measured, and the water quantity was examined under different precipitation levels. From the observation, outflow patterns of the water pollutants and changes in the water quality factors at the time of rainfall were clarified. In addition, estimation of the unit load was made for each stream; for Naerin-cheon at the time of rainfall, we estimated BOD to be $1,112kg/km^2/year$, T-N to be $2,077kg/km^2/year$, and T-P to be $223kg/km^2/year$; for Inbook-cheon at the time of rainfall, we estimated BOD to be $1,229kg/km^2/year$, T-N to be $1,565kg/km^2/year$, and T-P to be $255kg/km^2/year$. For the time of no rainfall different estimation was made; for Naerin-cheon, we estimated BOD to be $2,403g/km^2/day$, T-N to be $5,004g/km^2/day$, and T-P to be $53g/km^2/day$; and for Inbook-cheon, we estimated BOD to be $1,550g/km^2/day$, T-N to be $2,283g/km^2/day$, and T-P to be $42g/km^2/day$.

  • PDF

Energy Efficiency of Fluidized Bed Drying for Wood Particles

  • Park, Yonggun;Chang, Yoon-Seong;Park, Jun-Ho;Yang, Sang-Yun;Chung, Hyunwoo;Jang, Soo-Kyeong;Choi, In-Gyu;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.821-827
    • /
    • 2016
  • This study evaluates the economic feasibility of industrializing fluidized bed dryer for wood particles. The theoretically required heat energy and energy efficiency were evaluated using a pilot scale fluidized bed dryer. When Mongolian Oak wood particles with 50% initial moisture content were dried in the fluidized bed dryer with air of $70^{\circ}C$ air circulating at 1.1-1.3 m/s for 30 minutes, the total theoretically required heat energy was 2,177 kJ. Of this, 1,763 kJ (approximately 81.0%) was used to heat the air flowing in from outside the dryer and 386 kJ (approximately 17.7%) was used to heat and remove water from the wood particles. Actual energy consumed was 7,560 kJ, giving energy efficiency of 28.8%. Thus, to industrialize a drying method such as fluidized bed drying, where the dryer volume is significantly larger than the volume of wood particles, it is necessary to minimize energy loss and maximize energy efficiency by designing the dryer size considering the amount of wood particles and choosing a suitable air circulation rate.

An Experimental Study on Frost Generation Mechanism from Evaporator Tube in Air Conditioning System (공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구)

  • Park Sang-Kyun;Oh Cheal
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.113-117
    • /
    • 2006
  • The object qf this experiment was the evaluation of the growth rate of frost layer conditioned by inlet air's velocity, temperature and relative humidity on the copper tube in evaporator. In this experiment, the inlet air's velocity were $0.3^m/_s,\;0.6^m/_s,\;0.9^m/_s,$ temperature were $15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C$ and the variation of relative humidity was $70\%~90\%$. And the brine temperature flowing through the copper tubes was kept $-15{\circ}C$ because generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system It was found that the amount of frost generation increased so that the relative humidity, velocity and temperature of supply air increased.

Effects of the Sintering Atmosphere and Ni Content on the Liquid-phase Sintering of $TiB_2$-Ni

  • Suk-Joong L. Kang;Baung, Jin-Chul;Park, Yeon-Gyu;Kang, Eul-Son;Baek, Yong-Kee;Jung, Sug-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.3
    • /
    • pp.207-211
    • /
    • 2001
  • The effects of the sintering atmosphere and Ni content on t도 densification of TiB$_2$-Ni have been investigated. TiB$_2$powder compacts containing 10, 20, and 30 wt% Ni were liquid-phase sintered at 1500-1$700^{\circ}C$ in vacuum or in flowing Ar. The densification was enhanced as Ni content increased. For a given Ni content, the densification was faster in compacts in compacts with larger grain size. These densification behaviors agree well with the prediction of the recently developed pore-filling theory. For samples containing high Ni contents, 80TiB$_2$-20Ni and 70TiB$_2$-30Ni, the densification was faster in vacuum than in Ar. In particular, 70TiB$_2$-30Ni was fully densified at 1$700^{\circ}C$ for 60min in vacuum. The suppressed densification in Ar was due to the entrapped Ar in the isolated pores. On the other hand, for 90TiB$_2$-10Ni, the Ar-sintering resulted in higher densification than did the vacuum-sintering. This result was attributed to the suppression of Ni volatilization by the Ar in the furnace and a retarded isolation of pores due to the limited amount of liquid in the sample. Therefore, vacuum sintering is recommended for the preparation of TiB$_2$-Ni with a high Ni content while Ar sintering is recommended for the preparation of TiB$_2$-Ni with a low Ni content.

  • PDF

Hot Topic Prediction Scheme Using Modified TF-IDF in Social Network Environments (소셜 네트워크 환경에서 변형된 TF-IDF를 이용한 핫 토픽 예측 기법)

  • Noh, Yeonwoo;Lim, Jongtae;Bok, Kyoungsoo;Yoo, Jaesoo
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.4
    • /
    • pp.217-225
    • /
    • 2017
  • Recently, the interest in predicting hot topics has grown significantly as it has become more important to find and analyze meaningful information from a large amount of data flowing in social networking services. Existing hot topic detection schemes do not consider a temporal property, so they are not suitable to predict hot topics that are rapidly issued in a changing society. This paper proposes a hot topic prediction scheme that uses a modified TF-IDF in social networking environments. The modified TF-IDF extracts a candidate set of keywords that are momentarily issued. The proposed scheme then calculates the hot topic prediction scores by assigning weights considering user influence and professionality to extract the candidate keywords. The superiority of the proposed scheme is shown by comparing it to an existing detection scheme. In addition, to show whether or not it predicts hot topics correctly, we evaluate its quality with Korean news articles from Naver.