• Title/Summary/Keyword: flowing amount

Search Result 210, Processing Time 0.03 seconds

Magnetic Force Properties of Superconducting Bulk (초전도 벌크의 자기적 특성을 위한 간편한 시스템)

  • Sang Heon Lee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.70-73
    • /
    • 2023
  • To improve superconductor properties, the size of the crystal grains of the superconductor should be adjusted, the amount of electricity flowing through the superconductor should be increased, and the superconductor should be designed to withstand external magnetic fields. It is necessary to control the microstructure so that many flux pinning centers are developed inside the superconductor so that defects are generated physically or chemically, and the micro secondary phase for trapped magnetic flux must be dispersed inside the superconductor. In order to measure the superconducting magnetic force of the superconducting bulk in a simplified manner, the superconducting magnetic force was analyzed using an Nd-Fe-B permanent magnet of 3.80 kG. In particular, by delaying the growth of partially melted Y2BaCuO5 particles, we devised a plan to refine Y2BaCuO5 particles to effectively improve superconducting magnetic force, and analyzed superconducting magnetic force in a single crystal YBa2Cu3O7-y superconducting bulk using a gauss meter. The melted superconducting bulk traps 80% or more of the applied magnetic field, and can be used as a bulk magnet of high magnetic field magnetization applicable to electric power equipment.

Removal of Heavy Metal Ions in the Aqueous Solution Using Anodic Alumina and Retriculate Vitreous Carbon Electrodes (Anodic Alumina와 Retriculate Vitreous Carbon을 전극으로 사용하여 수용액에서 중금속이온의 제거)

  • Cho, Seung-Koo;Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.120-129
    • /
    • 2003
  • The anodic alumina is synthesized using 0.3M oxalic acid and the barrier layers of the anodic alumina are removed using the 20wt% $H_2SO_4$ solution. The structure of the anodic alumina is analyzed by XRD and SEM. It is observed by SEM that the size of anodic alumina pore is about 60nm. And the uniformity of the anodic alumina surface under the 20wt% $H_2SO_4$ solution is poorer than the unifomity of the the normal anodic alumina surface. The anodic alumina and the carbon are used cathode and anode in$Cd(NO_3)_2{\cdot}4H_2O$, $Co(NO_3)_2{\cdot}6H_2O$ and $PbSO_4$ solutions. In this study, the constant D.C. electrical current is flowed in each solution for 24hours. It is found that the voltages so far as 4.6, 3.4 and 5.1V at $Cd(NO_3)_2{\cdot}4H_2O$, $Co(NO_3)_2{\cdot}6H_2O$ and $PbSO_4$ solutions increase with increasing the flowing current time and after the voltage does not change which values are 4.2, 2.7 and 2.4V, respectively. The amount of metal ions in solutions decrease with increasing the flowing current time until the flowing current time is 18hours and the metals are formed at the surface of anodic alumina. After the metal ions are removed using the anodic alumina, and $Cd^{2+}$, $Co^{2+}$ and $Pb^{2+}$ ions are removed again using flow cell with retriculate vitreous carbon(RVC) working electrode. The concentration of $Cd^{2+}$, and $Co^{2+}$ions decrease until the flowing time of the solutions is 20minutes and the concentration of $Pb^{2+}$ ion decreases until that time is 30minutes. In this case, the removal effects of $Cd^{2+}$, $Co^{2+}$ and $Pb^{2+}$ ions are 34.78, 28.79 and 86.38%, respectively. And it is possible that both $Cd^{2+}$ and $Co^{2+}$ions are adsorbed in pore of RVC at the same time and the removal effects of $Cd^{2+}$ and $Co^{2+}$ions are 32.30 and 31.37%.

  • PDF

Design and Evaluation of a Flow Rotate Divider for Sampling Runoff Plots. (토양 유실량 및 유출수량 측정을 위한 회전분할집수기의 평가)

  • Zhang, Yong-Seon;Park, Chan-Won;Lee, Gye-Jun;Lee, Jeong-Tae;Jin, Yong-Ik;Hwang, Seon-Woong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.6
    • /
    • pp.374-378
    • /
    • 2008
  • For the standard method of collecting the run-off, it is consumed the high cost and much effort to install and to manage this instrument. Because the all the soil and water from reservoir tank must be eliminate after their measurement of amount of soil loss and run-off and installed the reservoir tank at regular size in the experimental field. Therefore, objective of this study was to compare its efficacy between the standard method and a flow rotate divider for ontinuously collecting and measuring the soil loss and run-off in order to conveniently conduct the field experiment of the lysimeters. For collecting the sampling of soil loss and run-off from agricultural land with invariable ratio, a flow rotate divider was consisted with a 8 blades of round plate sloped in order to collect the invariable ratio of soil and water at lowest part from round plate by the law of gravity. For comparing its accuracy in the batch scale experiment, it shown that there was significantly a positive linear corelation ($r=0.997^{***}$) between flowing and sampling amounts with adjusting the range from 1 to $10L\;min^{-1}$ with flowing rate. In collecting ratio in the field experiment, it observed that the more its accuracy had, the more soil loss and run-off.

Changes in Cooking of Marine Products Polluted with Mercury -(I) Fishes- (수은(水銀)으로 오염(汚染)시킨 해산물(海産物)의 조리(調理)에 따른 변화(變化) -(I) 어류(魚類)-)

  • Kim, Young-Hee;Park, Young-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.15 no.2
    • /
    • pp.144-147
    • /
    • 1986
  • This research is to investigate the changes in Mercury content of fishes, washed with times by the flowing water or immersed into the acetic acid solutions with different densities (1%, 3% and 5%), after contaminating them artificially on purpose, in the solutions with inorganic mercury. The results were summarized as follow: 1. Average values of mercury content in sand-fish and sardine, as a dried ones, which had not been treated by the mercurial solutions, were 0.027 ppm and 0.020 ppm, respectively. 2. According to the changes, with times, in contained by the flowing water, after immersed into 1 ppm $HgCl_2$ solution for 24 hours, The sand-fish washed for 9 minutes had the least of Mercury, which is about 25% of contained quantity of Mercury of those not cleansed. While the sardines cleansed for 3 minutes had the least of Mercury, which is about 77% of contained quantity of Mercury of those not cleansed. 3. According to the changes in contained quantity of the samples treated by the acetic acid solutions with different densities, the sand-fish treated by 3% acetic acid solution had the least value of remains, which was reduced by 64%, in comparision with that of fish cleansed for 1 minute, while the sardines, treated by 1% acetic acid solution had the least amount of remains, which was reduced by 16% in comparision with that of fish, cleansed for 1 minute.

  • PDF

Estimation of Pollution Loads flowing into Mokpo Harbour - Centering on Pollution Loads from Land in Dry Case - (목포항에 유입하는 오염부하량 산정 - 비강우시 육상오염부하를 중심으로 -)

  • Kim Kwang-Soo;Lee Nam-Il
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.1
    • /
    • pp.11-20
    • /
    • 2003
  • The pollution loads flowing into Mokpo harbour from land in dry case were estimated on the bases of the seasonal flow rates and the seasonal water qualities of streams and effluents located around Mokpo harbour. Average daily amount of fresh water Stowing into Mokpo harbour obtained by the inflow rate data of 4 seasons was found to be about 5.5×10/sup 6/㎥/day and annual inflow rate to be about 2×10/sup 9/㎥/year. The seasonal flow rates of effluents iron Yongsan lake were above 90% of total flow rates of all inflows in 4 seasons. The concentrations of COD, TSS, TIN and TP at 9 inflow stations Iron streams and effluents in 4 seasons were shown to be in the ranges of 2.87~42.69㎎/ℓ, 3.65~1080.32㎎/ℓ, 0.083~89.744㎎/ℓ and 0.028~6.926㎎/ℓ, respectively. The average loads of COD, TSS, TIN and TP into Mokpo harbour estimated by the data of 4 seasons were found to be about 37 ton/day, 64 ton/day, 13 ton/day and 1.2 ton/day, respectively. The loads of COD, TSS, TIN and TP into Mokpo harbour in summer were shown to be about 82 ton/day, 159 ton/day, 14 ton/day and 2 ton/day, respectively. The main source of pollution loads into Mokpo harbour was found to be the effluent of Yongsan lake.

  • PDF

Habitat Characteristics and Feeding Ecology of the Siberian Stone Loach Barbatula toni (Pisces: Namacheilidae) in the Bukcheon (Stream) (북천에 서식하는 종개 Barbatula toni(Pisces: Namacheilidae)의 서식지 특징 및 섭식생태)

  • Jeon, Yonglak;Ko, Myeong-Hun
    • Korean Journal of Ichthyology
    • /
    • v.33 no.4
    • /
    • pp.278-286
    • /
    • 2021
  • The habitat characteristics and feeding ecology of the Siberian stone loach Barbatula toni were investigated in Bukcheon (Stream), Eocheonri, Ganseong-eup, Goseong-gun, and Gangwon-do, Korea from January to December 2013. B. toni lived in rapids or slow rapids from the upper stream to downstream, with the largest number of inhabitants in the middle-downstream regions. As a result of analyzing habitat preferences by age, 0+ and 1+ to ≥3+ showed differences. Ages of 0+(juveniles) lived mainly in rapidly flowing water (37.6±26.79 cm/sec) and low water depths (13.3±9.47 cm) in the pebble bottoms (substratum particle size 9.5±6.66 cm), but ages 1+ to ≥3+ lived mainly in relatively slowly flowing water (13.3±17.33 cm/sec) and relatively deep depths (25.9±10.31 cm) in stone and large stone bottoms (substratum particle size 18.0±7.63 cm). B. toni was mainly eaten from March to December when the temperature was above 5℃, and the amount of food eaten peaked in June and October. Their main food sources analyzed by the index of relative importance (IRI) included Diptera (57.0%), Ephemeroptera (29.3%), and Trichoptera (13.5%). The juveniles (age 0+) fed on small-sized prey such as Diptera and Trichoptera whales, but as they grew, they mainly ate large-sized Ephemeroptera. These feeding habits and changes in food according to the growth of B. toni were very similar to those of sibling species, B. nuda.

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

A Scheme of Effective Water Quality Management on Lake Okjeoung (옥정호의 효율적인 수질관리방안)

  • Lee, Yo-Sang;Kim, U-Gu
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.487-497
    • /
    • 2001
  • Investigated data on Lake Okjeong were used for the simulation of water quality. According to the simulation results, the effective scheme of water quality management on reservoir has been proposed. It has been recognized that the water quality of Lake Okjeong is under eutrophic and mesotrophic condition even though there are seasonal variation. The water quality of lake is mainly affected by the inflow of pollutant load from watershed. Therefore, to estimate and quantify the accurate amounts of pollutants flowing into reservoir is absolutely necessary for the effective management of water quality on Lake Okjeong. When the pollutant load measured during 7 different rainy periods in 1999 was compared with total pollutant load in 1999. TN and TP measured during 7 different rainy periods showed almost 50% of total pollutant load. In case of SS, it was 72.8%. On the other hand, the rainfall amount measured during the 7 different rainy periods was about 17.5% of total rainfall amount in 1999. Release rate of TP shows 11.92 mg/L at fish farm site and 0.2∼1.9 mg/L at monitoring station of water quality on Lake Okjeong, and which is considered to be less than that of other foreign reservoirs under the circumstances of anoxic condition. For the effective management of water quality on Lake Okjeong. WASP5 water quality simulation model has been applied and verified, and the verified model was used to propose the effective scheme of water quality management. In this case, 6 different scenarios were applied, by changing the amount of inflow of pollutant load in each subbasin. The most effective scheme has turned out that pollutant load generated from Imsil and Gwanchon subbasin should be reduced, and the best way to improve the water a quality is to reduce the pollutant load at every subbasin. According to the simulation result, wastewater treatment facility should be located at every subbasin.

  • PDF

Landscape Value Analysis of Hallyǒ Haesang Sea National Park (한려해상국립공원(閑麗海上國立公園)의 경관자원(景觀資源) 가치분석(價値分析))

  • Kim, Sei-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.145-160
    • /
    • 2000
  • This study is focused to the national park of Korean typical Sea Hally$\check{o}$ Haesang, and its visual resources and practiced inspect course by the way of suppositions and tests, to show the visual resource management objectively, and that of qualitative basic data. Accordingly by measuring the physical amount spatial structure with the visual amount originated from the Mesh Analyzing Method and the Visual Preference from the Scenic Beauty Estimation(S.B.E.) method and analyzed the valuation of the visual resource by Iverson method. Spatial image structure measured by Semantic Differential(S.D.) Scale was shown through the factor analysis algorithm for the analyzing psychological amount and examined the flowing out of decisive factor and the objective importance related to the mutual factors by appling the measurement of the visual quality. As a national Park, the visual factors that have natural landscape harmonized with forest, sky, surface of the water, curious stones and rocks, and temples should be escalated their values affirmatively so as to be the scenery of pointed direction and enjoyable, and it is of more needed for visual resource and its' controlling technique to make artificial structures more intentional planning and systemical setting. When we are viewing the improvement for the national park along with the visual resource management, reasonable level of development is needed, because when men interference surpass plantations and leasts will be damaged and the quality of natural landscape can be lowered, so it is needed to set up a management end, tangibly or clearly; and it is permitted limit coming and going ablably by accounting the suitable number for availing. But the controling end should be set in every level, positive management, very actively within the permissive varcability. It is the main business for the national park to prevent the damage from human for their gay life or to prevent the damage of a land carpet, and to restorate for the visual resource management.

  • PDF