• Title/Summary/Keyword: flow pattern generation

Search Result 101, Processing Time 0.027 seconds

OXYGEN CONCENTRATION IN THE CATHODE CHANNEL OF PEM FUEL CELL USING GAS CHROMATOGRAPH

  • Ha, T.H.;Kim, H.S.;Min, K.D.
    • International Journal of Automotive Technology
    • /
    • v.8 no.1
    • /
    • pp.119-126
    • /
    • 2007
  • Because of the low temperature operation, proton exchange membrane (PEM) fuel cell has a water phase transition. Therefore, water management is an important operation issue in a PEM fuel cell because the liquid water in the fuel cell causes electrode flooding that can lower the cell performance under high current density conditions. In this study, in order to understand the reactant distributions in the cathode channels of the PEM fuel cell, an experimental technique that can measure the species concentrations of reactant gases by using gas chromatograph (GC) is applied for an operating PEM fuel cell. The oxygen distribution along the cathode flow channels of PEM fuel cell is mainly investigated with various operating conditions. Also, the relations between cathode flooding and oxygen concentrations and oxygen consumption pattern along the cathode channel configurations of the unit cell adopted for this study are discussed using GC measurement and visualization experiment of cathode flooding. It is found that the amount of oxygen consumption is very sensitive to various operating conditions of the fuel cell and was much affected by the flooding occurrence in cathode channels.

High-level Modeling and Test Generation With VHDL for Sequential Circuits (상위레벨에서의 VHDL에 의한 순차회로 모델링과 테스트생성)

  • Lee, Jae-Min;Lee, Jong-Han
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.5
    • /
    • pp.1346-1353
    • /
    • 1996
  • In this paper, we propose a modeling method for the flip-flops and test generation algorithms to detect the faults in the sequential circuits using VHDL in the high-level design environment. RS, JK, D and T flip-flops are modeled using data flow types. The sequence of micro-operation which is the basic structure of a chip-level leads to a control point where varnishing occurs to one of two micro- operation sequence. In order to model the fault of one micro-operation(FMOP) that perturb another micro-operation effectively, the concept of goal trees and some heuristic rules are used. Given a faulty FMOP or fault of control point (FCON), a test pattern is generated by fault sensitization, path sensitization and determination of the imput combinations that will justify the path sensitization. The fault models are restricted to the data flow model in the ARCHITECTURE statement of VHDL. The proposed algorithm is implemented in the C language and its efficiency is confirmed by some examples.

  • PDF

CFD Analysis on a Tall Building Augmented Wind Turbine (풍력발전기가 설치된 고층빌딩에 대한 전산유체역학적 고찰)

  • Jeon, Wan-Ho;Yoon, Seong-Wook;Kim, Wook;Cho, Jang-Hyung
    • Journal of Environmental Science International
    • /
    • v.18 no.8
    • /
    • pp.919-926
    • /
    • 2009
  • Renewable energy or green energy is a hot issue in theses days. Since wind resource can be endlessly supplied by nature, researchers and common people are interested in study how to use that resource at home or company. Especially, many architects have tried to integrate wind power generator for a part of building. So in this paper, three buildings installed wind power turbine are targed to CFD analysis and these buildings are Bahrain trade center, Discovery tower, and Pearl river tower. Bahrain trade center is the first building installed real wind turbine, Discovery tower is constructing at Texas, and Pearl river tower is designed and proved by china researchers. These buildings have very different type of wind power turbine and each turbine has different conditions f3r best power generation. Therefor this paper will focus on characteristic shape of buildings, wind power turbine type, and expected purpose of construction. Moreover, CFD analysis will show wind flow pattern and wind speed while wind is passing through wind turbine of three tall buildings. CFD analysis for three buildings make comparison the wind flow patterns with experimental result.

Improved Method of Maximum Loadability Estimation in Power Systems By Transforming the Distorted P-e Curve (왜곡된 P-e곡선의 변환에 의한 전력계통 최대허용부하의 향상된 추정 방법)

  • Hwang, Ji-Hwan;Choi, Byoung-Kon;Cho, Byoung-Hoon;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.363-365
    • /
    • 2000
  • This paper presents an improved method to estimate the maximum load level for heavily loaded power systems with the load-generation variation vector by using the elliptic pattern of the P-e curve. The previous study suggested a simple technique of removing e-f coupling, where only high voltage load flow solutions to calculate transforming angle of system reference is needed. The proposed algorithm is improved to require only one load flow solution at a specific load level in addition to the operating point at the beginning stage, which reduces the computation time and the iteration number of estimation. The proposed method can be efficiently applied to heaviIy loaded systems with the combination of CPFlow when the reactive power limit and ULTC are considered. In this paper, the effect of ULTC on the estimation of maximum loadability index is also investigated. The proposed algorithm is tested on New England 39 bus system and IEEE 118 bus system.

  • PDF

CFD Analysis on a Tall Building Augmented Wind Turbine (풍력발전기가 설치된 고층빌딜에 대한 전산유체역학적 고찰)

  • Jeon, Wan-Ho;Yoon, Seong-Wook;Kim, Wook;Cho, Jang-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.418-421
    • /
    • 2009
  • Renewable energy or green energy is a hot issue in theses days. Since wind resource can be endlessly supplied by nature, researchers and common people are interested in study how to use that resource at home or company. Especially, many architects have tried to integrate wind power generator for a part of building. So in this paper, three buildings installed wind power turbine are targed to CFD analysis and these buildings are Bahrain trade center, Discovery tower, and Pearl river tower. Bahrain trade center is the first builidng installed real wind turbine, Discovery tower is constructing at Texas, and Pearl river tower is designed and proved by china researchers. These buildings have very different type of wind power turbine and each turbine has different conditions for best power generation. Therefor this paper will focus on characteristic shape of buildings, wind power turbine type, and expected purpose of construction. Moreover, CFD analysis will show wind flow pattern and wind speed while wind is passing through wind turbine of three tall buildings. CFD analysis for three buildings make comparison the wind flow patterns with experimental result.

  • PDF

Flow Behavior of Thin Polymer Film by various patterns in Spinning Coating Process of Blu-ray Disc Cover layer (블루레이 디스크의 커버레이어 스핀 코팅 시 다양한 패턴에 따른 최적화된 폴리머 거동에 관한 연구)

  • Cho K. C.;Park Y. H.;Kim H. Y.;Kim B. H.;Lee B. G.;Son S. G.;Shin H. K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.467-471
    • /
    • 2005
  • In this paper, experimental methods about the flow behavior of thin polymer film by various edge patterns in the spin coating process for stable cover layer coating of a blu-ray disc is described. The blu-ray disc, a next-generation optical disc format over 25GB, consists of a 1.1m thick substrate and a 0.1mm tick cover layer. Generally, cover layer on the blu-ray disc is made by the polymer spin coating process. However, it is hard to secure sufficient coating uniformity around the rim on the cover layer. In order to get the uniform thickness deviation and to minimize the bead around the rim, the edge of the disc substrate can be modified into various patterns, such as normal plain, trench, step and chamfer pattern, etc, around the rim on the disc and experimented with various parameters, such as surface tension, viscosity, coating time, temperature and rotation speed, etc. And the optimal shape of the rim was tried to get by 3 dimensional computer simulation of the polymer expulsion process.

  • PDF

Internal Structure and Velocity Field of the Impinging Diesel Spray on the Wall (디젤 충돌 분무의 발달 과정 및 내부 유동 특성)

  • Chon, M.S.;Suh, S.K.;Park, S.W.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.1-8
    • /
    • 2005
  • The purpose of this study is to investigate the internal structure of the impinged diesel spray at various experimental conditions. To examine the effect of various factors on the development of a diesel spray impinging on the wall, experiments were conducted at the various Injection pressures, wall distances from the nozzle tip and angles of wall inclination. The PIV system consists of a double pulsed Nd:YAG laser was utilized to analyze the internal flow structure of impinged diesel sprays. The velocity fields from the PIV system were compared with the results measured by the phase Doppler particle analyzer(PDPA)system. The results show that internal flow pattern of the impinged spray was similar with the results from the PDPA system. The radial velocity of the impinged spray was increased with the increase in the injection pressure and near the nozzle-wall distance. The generation of vortex was also promoted with the Increase in angles of wall inclination.

  • PDF

Regionalized Sensitivity Analysis of Extended TOPMODEL (확장 TOPMODEL의 영역화 민감도 분석)

  • Kim, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.6
    • /
    • pp.741-755
    • /
    • 1998
  • An extension of TOPMODEL was developed for rainfall-runoff simulation in agricultural watersheds equipped with tile drains. Tile drain functions are incorporated into the framework of TOPMODEL. Nine possible flow generation scenarios are suggested for tile drained watershed and applied in the modeling procedure. In the model development process, the traditional physically based storage approach and a new approach using a transfer function for the simulation of the flow in the unsaturated zone were compared. In order to provide better insight into the simulation process, a regionalized sensitivity analysis was performed to test the performance of the model and to compare the behavior of the transfer function to that of the simple storage related formulation. The results of analysis show good performance of the transfer function approach. Since the rainfall-runoff response pattern tends to vary seasonally, seven events distributed throughout a year were used in the sensitivity analysis to investigate the seasonal variation of the hydrologic characteristics. It is found that the sensitivity of each parameter described by the model are varied seasonally.

  • PDF

Numerical Simulation of a 100 $MW_e$-scale Wall-fired Boiler for Demonstration of Oxy-coal Combustion (전산유동해석을 이용한 100 $MW_e$급 석탄 순산소 연소 실증 보일러의 설계 및 운전조건 평가)

  • Chae, Tae-Young;Park, Sang-Hyun;Hong, Jae-Hyeon;Yang, Won;Lee, Sang-Hoon;Ryu, Chang-Kook
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • As one of the main technologies for carbon capture and storage in power generation, oxy-coal combustion is being developed for field demonstration in Korea. This study presents the results of numerical simulation for combustion in a single-wall-fired 100 $MW_e$-scale boiler proposed for the initial design of the demonstration plant. Using a commercial CFD code, the detailed combustion, flow and heat transfer characteristics were assessed both for air-mode and oxy-mode combustion. The results show that stable combustion can be achieved in the dual mode operation with the current boiler configuration. However, the differences in the flow pattern and heat transfer between the two combustion modes need to be considered in the design and operation which is mainly due to the larger density and specific heat of $CO_2$ compared to $N_2$. Further development of the boiler design is required using improved numerical modeling for radiative heat transfer and combustion.

Investigation of growth-in defects distribution in Si single crystal (실리콘 단결정내의 grown-in 결함 분포에 관한 고찰)

  • 이보영;황돈하;유학도;권오종
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.539-543
    • /
    • 1998
  • The relationship of growth-in defects such as crystal originated particles (COP), flow pattern defects(FPD), laser scattering tomography defects (LSTD) was investigated in Cz-Si single crystals which had different pulling speed during crystal growing. It is concluded that the density and radial distribution of grown-in defects is strongly dependent on the pulling speed. And as the generation areas of these grown-in defects in a wafer are identical in radial position, they can be generated from same origin during crystal growing.

  • PDF