• Title/Summary/Keyword: flow pattern

Search Result 2,330, Processing Time 0.03 seconds

NUMERICAL STUDY OF FLOW PATTERNS PAST AN INCLINED SQUARE CYLINDER (기울어진 정방형 실린더를 지나는 유동패턴의 수치해석적 연구)

  • Yoon, Dong-Hyeog;Yang, Kyung-Soo;Choi, Choon-Bum
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.19-24
    • /
    • 2009
  • A parametric study has been carried out to elucidate the characteristics of flow past a square cylinder inclined with respect to the main flow for Re$\leq$150. Reynolds number and angle of incidence are the key parameters which determine the flow characteristics. This study would be the first step towards understanding flow pattern past a cylindrical structure under a strong gust of wind from the viewpoint of wind hazards. A complete classification of flow pattern has been obtained in the laminar region.

Numerical Signal Prediction and Calibration Using the Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Slug Flow (슬러그 2상유동에서 전류형식 전자기유량계 수치적 신호예측 및 보정)

  • Ahn Yeh-Chan;Oh Byung Do;Kim Jong-Rok;Kim Moo Hwan;Kang Deok-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.671-686
    • /
    • 2005
  • The transient nature and complex geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et al.). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. The velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method, and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for simulating slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are proposed for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow (2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산)

  • Oh, Byung-Do;Kim, Moo-Hwan;Ahn, Yeh-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

Thermal Behavior of Flow Pattern Defect and Large Pit in Czochralski Silicon Crystals and Effects of Large Pit upon Device Yield (쵸크랄스키 Silicon 단결정의 Large Pit과 Flow Pattern defect의 열적 거동과 Large Pit의 소자 수율에의 영향)

  • Song, Yeong-Min;Mun, Yeong-Hui;Kim, Jong-O;Jo, Gi-Hyeon
    • Korean Journal of Materials Research
    • /
    • v.11 no.9
    • /
    • pp.781-785
    • /
    • 2001
  • The thermal behavior of Flow Pattern Defect (FPD) and Large Pit (LP) in Czochralski Silicon crystal was investigated by applying high temperature annealing ($\geq$$1100^{\circ}C$) and non-agitated Secco etching. For evaluation of the effect of LP upon device performance/yield, commercial DRAM and ASIC devices were fabricated. The results indicated that high temperature annealing generates LPs whereas it decreases FPD density drastically. However, the origins of FPD and LP seemed to be quite different by not showing any correspondence to their density and the location of LP generation and FPD extinction. By not showing any difference between the performance/yield of devices whose design rule is larger than 0.35 $\mu\textrm{m}$, LP seemed not to have detrimental effects on the performance/yield.

  • PDF

A simplified vortex model for the mechanism of vortex-induced vibrations in a streamlined closed-box girder

  • Hu, Chuanxin;Zhao, Lin;Ge, Yaojun
    • Wind and Structures
    • /
    • v.32 no.4
    • /
    • pp.309-319
    • /
    • 2021
  • The vortex-drift pattern over a girder surface, actually demonstrating the complex fluid-structure interactions between the structure and surrounding flow, is strongly correlated with the VIVs but has still not been elucidated and may be useful for modeling VIVs. The complex fluid-structure interactions between the structure and surrounding flow are considerably simplified in constructing a vortex model to describe the vortex-drift pattern characterized by the ratio of the vortex-drift velocity to the oncoming flow velocity, considering the aerodynamic work. A spring-suspended sectional model (SSSM) is used to measure the pressure in wind tunnel tests, and the aerodynamic parameters for a typical streamlined closed-box girder are obtained from the spatial distribution of the phase lags between the distributed aerodynamic forces at each pressure point and the vortex-excited forces (VEFs). The results show that the ratio of the vortex-drift velocity to the oncoming flow velocity is inversely proportional to the vibration amplitude in the lock-in region and therefore attributed to the "lock-in" phenomena of the VIVs. Installing spoilers on handrails can destroy the regular vortex-drift pattern along the girder surface and thus suppress vertical VIVs.

A Dye Tracer Study of Infiltration Pattern in a Residual Soil Developed from Granite (화강암 기원 잔적토양에서 염료추적자의 침투 유형에 관한 연구)

  • 전철민;김재곤;이진수;김탁현
    • Economic and Environmental Geology
    • /
    • v.37 no.4
    • /
    • pp.383-389
    • /
    • 2004
  • Understanding flow pattern of water and solute in subsurface is essential for the reduction and prevention of contamination of soil and groundwater and for the investigation and remediation of contaminated site. The objective of this study is to examine the infiltration pattern in a soil developed from the Jurassic granite using (Brilliant Blue FCF $C_{37}H_{34}N_{2}Na_{2}O_{9}S_{3}$), the nonfluorescent and nontoxic food dye. All image processing was conducted using geographic image processing software, ER Mapper, Version 6.2. The dye coverage was determined by counting the stained pixels in the photographs (80${\times}$80cm, 80TEX>${\times}$5cm) for the vertical and horizontal view. A homogeneous matrix flow occurred in the A horizon with weak, medium granular structure and fingering at the interface of finer-textured A horizon and coarser-textured C horizon. Pegmatitic vein originated from the granite and plant root in C horizon induced preferential flow.

Numerical simulations of the vertical kink oscillations of the solar coronal loop with field aligned flows

  • Pandey, V.S.;Magara, T.;Lee, D.H.;Selwa, M.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.103.1-103.1
    • /
    • 2011
  • Recent observations by Hinode show weakly-attenuated coronal loop oscillations in the presence of background flow (Ofman & Wang 2008, A&A, 482, L9). We study the vertical kink oscillations in solar coronal loops, considering field aligned flows inside the loops as well as surrounding the loops environment. The two dimensional numerical model of straight slab is used to explore the excitation and attenuation of the impulsively triggered fast magnetosonic standing kink waves. A full set of time dependent ideal magnetohydrodynamics equations is solved numerically taking into account the value of flow of the order of observed flows detected by SOT/Hinode. We find that relaxing the assumption of the limited flows within the loops enhances the damping rate of the fundamental mode of the standing kink waves by 2 - 3 % as compared to flow pattern which is basically localized within the loops. We further notice that extending the flow pattern beyond the loop thickness also enhances the strength of the shock associated with slow magnetoacoustic waves, recognized as an addition feature detected in the numerical simulation. The wider out-flow pattern destroys the oscillation patterns early as compared to narrower flow pattern, in other words we can say that it affects the durability of the oscillation. However, for the typical coronal loops parameters we find that the observed durability periods of the SOT/Hinode observation can be achieved with an out-flow Gaussian patterns for which half-width is not greater than factor 2.0 of the loop-half-width. explain a possible relation between electric current structure and sigmoid observed in a preflare phase.

  • PDF

Functional Areas of Kwang-ju City through Analysis of the Taxi-flow Pattern (택시통행패턴에 따른 광주시 기능지역 분석)

  • 김영기
    • Journal of Korean Society of Transportation
    • /
    • v.6 no.2
    • /
    • pp.35-48
    • /
    • 1988
  • Amongst various analytic methods of internal structure of city, the factor analysis method which uses O-D matrix data has some merits and characteristics compared to other methods. 1) It is possible to find one certain interaction and flow pattern between traffic zones with in a city through reanalyzing O-D data which is too complex to grasp specific meaning or pattern of flow systems. 2) It can be easily visualized the traffic flow pattern by using adequate graphic techniques, and also can clarify the functional areas whose interaction linkages are significantly strong enough between each other. In this study, the taxi traffic O-D data between 42 traffic zones in Kwang-ju city was reanalyzied by varimax rotated factor analysis methods. As a result, four factors that have significant level factor loading (over 0.5 ) and factor score (over 1.0) were sorted out. so to speak four different functional areas were clarified in Kwang-ju city, of the West, the East, the south, and the North functional areas whose interaction linkages are significantly strong enough between each other. In the study, the taxi traffic O-D data between 42 traffic zones in Kwang-ju city was reanalyzied by varimax rotated factor analysis methods. As a result, four factors that have significant level factor loading (over 0.5) and factor score 9over 1.0) were sorted out. so to speak four different functional areas were clarified in Kwang-ju city, of the West, the East, the South, and the North functional area, then these four functional areas are almost coincided with citizen's general conception of community division and administrative district. Accordingly the factor analysis methods using traffic data seems to proved to be very accurate and useful analytic instruments for analyzing flow pattern and clarifying functional areas of city, and believed to provide basic informations and criteria for practical urban land use planning and transportation planning.

  • PDF

A Study on Cause of Defects in NIL Molding Process using FEM (유한요소 해석을 이용한 나노임프린트 가압 공정에서 발생하는 결함 원인에 대한 연구)

  • Song, N.H.;Son, J.W.;Kim, D.E.;Oh, S.I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.364-367
    • /
    • 2007
  • In nano-imprint lithography (NIL) process, which has shown to be a good method to fabricate polymeric patterns, several kinds of pattern defects due to thermal effects during polymer flow and mold release operation have been reported. A typical defect in NIL process with high aspect ratio and low resist thickness pattern is a resist fracture during the mold release operation. It seems due to interfacial adhesion between polymer and mold. However, in the present investigation, FEM simulation of NIL molding process was carried out to predict the defects of the polymer pattern and to optimize the process by FEA. The embossing operation in NIL process was investigated in detail by FEM. From the analytical results, it was found that the lateral flow of polymer resin and the applied pressure in the embossing operation induce the weld line and the drastic lateral strain at the edge of pattern. It was also shown that the low polymer-thickness result in the delamination of polymer from the substrate. It seems that the above phenomena cause the defects of the final polymer pattern. To reduce the defect, it is important to check the initial resin thickness.

  • PDF

Identification of Internal Flow Pattern in Effervescent Atomizers (기체주입노즐의 내부유동양식의 구분)

  • Kim, Joo-Youn;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.306-315
    • /
    • 2000
  • An experimental study was conducted to examine the internal flow patterns inside the mixing chamber of effervescent atomizers. The mixing chamber has the rectangular cross section ($8mm{\times}2mm$) and made of transparent acrylic plate for flow visualization. The parameters tested were the air/liquid ratio (ALR), injection. pressure, and the nozzle orifice diameter. Three different flow regimes were observed; bubbly, annular, and intermittent flows. In the bubbly flow regime, the discharged mixture was disintegrated into drops through the bubble expansion and the ligament breakup. On the other hand, in the annular flow regime, the liquid annulus was disintegrated into small drops by the aerodynamic interaction between the phases due to the high relative velocities between the gas and the liquid. In the intermittent flow regime, the bubble-expansion/ligament-disintegration mode and the annulus-disintegration mode appeared alternatively. The correlations representing the transition criteria between the two-phase flow patterns within the mixing chamber were proposed based on the drift-flux models.