• Title/Summary/Keyword: flow monitering

Search Result 13, Processing Time 0.031 seconds

Sanitary sewer flow characteristics through a depth-velocity scatter graph analysis (수위-유속 분산 그래프를 통한 하수흐름 특성 분석)

  • Son, Jooyoung;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.647-655
    • /
    • 2014
  • To perform long-term sewer monitoring, It is important to understand the nature of the wastewater flow that occurs at the point on early stage of the monitor and to prevent in advance a problem which may caused. We can infer the flow properties and external factors by analyzing the scatter graph obtained from the measured data flow rate monitoring data since an field external factor affecting the sewage flow is reflected in the flow rate monitoring data. In this study, Selecting the three points having various external factors, and we Inferred the sewer flow characteristics from depth-velocity scatter graph and determined the analysis equation for the dry-weather flow rate data. At the'point 1' expected non-pressure flow, we were able to see the drawdown effect caused by the free fall in the manhole section. At the'point 2', existed weir and sediments, there was backwater effect caused by them, and each of size calculated from the scatter graph analysis were 400 mm and 130 mm. At the'Point 3', there is specific flow pattern that is coming from flood wave propagation generated by the pump station at upstream. In common, adequate equations to explain the dry weather flow data are flume equation and modified manning equation(SS method), and the equations had compatibility for explaining the data because all of $R^2$ values are over 0.95.

Application of Hydrological Monitoring System for Urban Flood Disaster Prevention (도시홍수방재를 위한 수문모니터링시스템의 적용)

  • Seo, Kyu-Woo;Na, Hyun-Woo;Kim, Nam-Gil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1209-1213
    • /
    • 2005
  • It reflects well feature of slope that is characteristic of city river basin of Pusan local. Process various hydrological datas and basin details datas which is collected through basin basis data. weather satellite equipment(EMS-DEU) and automatic water level equipment(AWS-DEU) and use as basin input data of ILLUDAS model, SWMM model and HEC-HMS model In order to examine outflow feature of experiment basin and then use in reservoir design of experiment basin through calibration and verification about HEC-HMS model. Inserted design rainfall for 30 years that is design criteria of creek into HEC-HMS model and then calculated design floods according to change aspect of the impermeable rate. Capacity of reservoir was determined on the outflow mass curve. Designed imagination reservoir(volume $54,000m^3$) at last outlet upper stream of experiment basin, after designing reservoir. It could be confirmed that the peak flow was reduced resulting from examining outflow aspect. Designing reservoir must decrease outflow of urban areas.

  • PDF

A study on Compare Characteristics of Nonpoint Source in Storm-water versus Steepness of Field Slope (밭경사에 따른 강우유출수 내의 비점오염물질 특성 비교 분석)

  • Kim, Gi-Cheol;Choe, Yong-Hun;Won, Cheol-Hui;Choe, Jung-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1093-1102
    • /
    • 2009
  • This study was focused on analyse Nonpoint source characteristics from Flat slope field and Steep slope field. We performed Storm-water monitering for obtain flow data and concentration data. Totally, eleven times Event was occurred. We calculated EMC(Event Mean Concentration) and Pollutants Loads using data we obtained. As a result, steep slope field has more discharge than flat field. SS value, one of the water quality contents, has largest variation and T-N has least variation. There is runoff differences even though events has same rainfall. We assume that not only amount of Rainfall, but also Rainfall Duration Times, Intensity, Number of Previous Non-precipitation days can affect to Run-off.

  • PDF

Lagrangian Observations of Currents in the Coastal Regions off East Coast of Korea (라그랑쥐 측류에 의한 동해 연안역 유동특성 관측)

  • 이문진;강용균;강신영;유홍선
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.1 no.2
    • /
    • pp.53-60
    • /
    • 1995
  • We measured lagrangian currents in the coastal regions off east coast of Korea. The experiment sites are the Ulijin region where Polar Front of the East Sea is formed and the Ulgi region where coastal upwelling occurs frequently in summer. Each drifters are equipped with GPS receiver, and their trajectories are montiored by receiving the data transmitted from drifters through radio signal. The experiment with 'transmitting' GPS is very useful in monitering flows in coastal regions. Trajectories of drifters in the Uljin Polar Front region in October 1994 showed counterclockwise flow pattern. The flow pattern agrees with the SST distributions obtained from NOAA-11 AVHRR image for the same period. The lagrangian trajectories of drifters at 5m and 15m depths in the Ulgi region for normal period of April 1995 showed that the currents at the top 15m layer are almost uniform and their magnitude is 29cm/s. However, the currents, measured by KORDI, during the upwelling period of June 1994 showed that the currents at 5m depth were 1.2 times stronger than those at 15m depth. The current pattern in the Ulgi upwelling region agrees with the horizontal and vertical distributions of seawater temperature measured by NFRDA at the same period.

  • PDF

An Experimental Study on the Solar Hot Water Heating System for the Dormitory of University (기숙사 태양열 급탕시스템의 열성능에 관한 실증연구)

  • Shin, U-Cheul;Baek, Nam-Choon;Kwak, Hee-Yeul;Ju, Hyunlo-Lo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.103-109
    • /
    • 2006
  • The Purpose of this work is to investigate a long-term thermal performance of active solar hot water heating system for the dormitory of university. For this, monitering system including temperature sensors, flow-meters was installed in this system. Measurement was continued for 13 months between April 1st 2004 and May 31th 2005. As results, hot water demand, daily and monthly hot water load distribution which are necessary for the solar system design were suggested. Also thermal stratification in solar buffer tank was observed in the point of increasement of system efficiency. The yearly solar fraction and system efficiency of this system are about 29.5% and 44.9% respectively.

Application of Geostatistical Analysis Method to Detect the Direction of Sea Surface Warm Flows (해수면 난류수 유동방향 탐지를 위한 지구통계학적 분석기법 적용)

  • Choi, Hyun-Woo;Kim, Hyun-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.1
    • /
    • pp.168-178
    • /
    • 2006
  • In recent years, an ingress of mass jellyfish into cooling water intake system causes interruption of electric power production at the Uljin nuclear power plant. Therefore, monitering and forecast on the mass ingress of marine organisms are demanded as one of the early preventing measurements. Sea water movement is a major factor on the ingress of marine organisms like Moon jellyfish which has weak self-mobile ability. When sea surface flow direction adjacent to the Uljin is the northwest, the jellyfish on the Tsushima warm currents move to the Uljin power plant. To detect the direction of sea surface warm flows, the spatial range with $25km{\times}25km$ is set up and NOAA sea surface temperature(SST) data are collected in this area. For the statistical analysis, the SST data are made as GIS point data and geostatistical analysis of ArcGIS is used. Analyzing directional semivariogram, the anisotropy of the SST point data are calculated and warm flow direction is detected. This experimental results are expected to use as an element technology for the early warning system development of mass jellyfish ingress in power plant.

  • PDF

Design of Path Weighting Data Analysis System for Efficient Product Arrangement (효율적인 상품 배치를 위한 경로 가중치 데이터 분석 시스템 설계)

  • Kim, Bong-Hyun
    • Journal of Digital Convergence
    • /
    • v.14 no.10
    • /
    • pp.167-172
    • /
    • 2016
  • Commercial analysis has been used for a lot of reasons such as improving the distribution structure, operational cost savings. However, existing commercial assay system is mostly flow through the analysis of the population and the environment around the store. Therefore, in this paper, we design a path weighted data analysis system for efficient product arrangement. It is not applying the analysis method of the existing commercial sales center but the data analysis system applying the weight to the form of customers' paths in a store. In conjunction with the existing POS system, it provides effective product placement in department stores, such as supermarkets, convenience stores. To this end, a system that maximizes efficiency of product placement in stores, receiving path data, converting them into statistics data that apply the weight, and printing out them into a visualized monitering system for the manager to see was designed.

A study on Land use Survey and Monitoring Forcused on the Subway Station Areas in Taejeon (도시철도 역세권의 공간이용 모니터링을 위한 기초연구)

  • Cho, Byung-Ho;Choi, Bong-Moon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.457-465
    • /
    • 2011
  • This research, which was started with a need for constant monitoring to find out urban societies and spacial effects by urban railway after the opening, was intended to empirically explore urban and social changes by the opening of Daejeon City metro line 1st which would greatly affect the spacial structure of the city. For this goal, we expected the effect of urban subway on the city with academic consideration and precedent study. Monitoring results of the subway station areas of Daejeon City metro line 1st showed the opening of urban railway had an influence on the flow of urban plan and urban space structure through population, land use, total-developing areas, and land price change. In other words, as urban railway opens the number of population and population activities centered on the subway station areas, and these movements led to the expansion of the commercial areas. Finally, they caused the average land prices to rise. Likewise, urban monitering is significantly useful comprehending the generally time-periodic changes of cities and even conceiving the present cities.

Development of GIS System for the Monitering of the Riverbed Sediment on Dam Reservoir (댐저수지 하상의 퇴적물 관리를 위한 GIS 시스템 개발)

  • Park, Joon-Kyu
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.11a
    • /
    • pp.33-45
    • /
    • 2006
  • The interest of sediment has been increased daily because most of domestic dam reservoir's operation time have been extended and wide basin area is the main characteristics for artificial reservoir which the speed of water flow in artificial reservoir is slower than that of natural reservoir. Therefore a lot of sediment has been significantly accumulated. In this study, the accurate topographic data were obtained using echo-sounding system. GPS survey, low-frequency sub-bottom profiler, and high-frequency echo-sounding system were used to compute the exact amount of sediment. Based on the results, DEM(Digital Elevation Model) and DSM(Digital Surface Model) were generated. The GIS system for the management of sediment was created based on topographic data on the riverbed and this system can be efficiently used for the management of sediment which caused the problems of reservoir capacity and water quality.

  • PDF

Determination of EMC and Unit Loading of Rainfall Runoff from Forestry-Crops Field (산림과 밭 지역 강우 유출수의 EMC 및 원단위 산정)

  • Won, Chul-hee;Choi, Yong-hun;Seo, Ji-yeon;Kim, Ki-cheol;Shin, Min-hwan;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.615-623
    • /
    • 2009
  • The research of the determination of event mean concentration (EMC) was focussed combined sewer overflows and highway runoff in korea. But those of non-urban areas are few. In this study, EMC and unit loading on land use types in Nogok watershed were estimated by runoff loading of non-point source (NPS) on non-urban area. Two monitoring sites were equipped with an automatic velocity meter, flow meter, and water sampler. Monitoring was conducted at two monitering site during the rainy season. The results show that the EMC ranges in forest land use are 1.3~2.6 mg/L for BOD, 2.0~16.1 mg/L for SS, 0.1~2.1 mg/L for TN, and 0.12~0.49 mg/L for TP. The unit loading of NPS in this study was difficult to compare directly with that used conventionally because of the difference of field investigation. In near future, it needs to conduct more systematic and long-term research about NPS within the watershed. The results of this research can be used to estimate the total pollution load management system (TPLMS) program in korea.