• Title/Summary/Keyword: flow measurement

Search Result 3,208, Processing Time 0.035 seconds

PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan

  • Shigemitsu, Toru;Fukuda, Hiroaki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.2
    • /
    • pp.175-181
    • /
    • 2016
  • Contra-rotating rotors have been adopted for some of the cooling fans to meet the demand for the high pressure and large flow rate. Therefore, it is important to clarify its inlet and outlet flows by experiments for the high performance and stable operation. PIV measurements were conducted at the design and partial flow rates. In the present paper, the inlet and outlet flow conditions of the contra-rotating small-sized cooling fan with a 40mm square casing are studied by using PIV measurement. Furthermore, improvements of the flow condition and design guideline to increase the performance were discussed based on the experimental results.

Advanced Flow Visualization Technologies and Blue Ocean Strategy (첨단 유동가시화 기법들과 Blue Ocean 전략)

  • Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.145-146
    • /
    • 2006
  • Recently, the next-generation advanced flow visualization techniques such as holographic PIV, dynamic PIV, echo-PIV, micro/nano-PIV, and X-ray PIV have been introduced. These advanced measurement techniques have a big potential as the core technology for analyzing outmost thermo-fluid flows in future. These would be indispensable in solving complicated thermo-fluid flow problems not only in the industrial fields such as automotive, space, electronics, aero- and hydro-dynamics, steel, and information engineering, but also in the research fields of medical science, bio-medical engineering, environmental and energy engineering etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is impossible for conventional measurement methods to observe most complicated nano- and bio-fluidic phenomena. In this presentation, the basic principle of these high-tech flow visualization techniques and their practical applications which cannot be resolved by conventional methods, such as blood flows in a micro-tube, in vivo analysis of micro-circulation, and flow around a living body will be introduced as a blue ocean strategy.

  • PDF

A study on flow characteristics in a partially filled open channel (비만관 개수로 유동 특성 연구)

  • Choi, Jung-Geun;Sung, Jae-Yong;Lee, Myeong-Ho;Lee, Suk-Jong
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.73-77
    • /
    • 2006
  • Flow rate measurement is one of the difficult problems in the industrial applications. Especially, flow rate in a partially filled pipeline is affected by many parameters such as water level, channel slop, etc. In the present study, prior to the development of a flowmeter, the flow characteristics has been investigated by particle image velocimetry (PIV) measurements. Three-dimensional velocity distributions were obtained from sectional measurements of velocity profiles according to the water level. As a result, it is found that there is no similarity in the velocity profile when the lateral position is changed. In addition, the maximum velocity does not always occur on the free surface. It depends on the water level. In the aspect of flow rate measurement, the previous calculus based upon point measurement techniques is proved to be inaccurate because of the lack of whole flow information.

  • PDF

Numerical and Experimental Analyses of a Hot-Wire Gas Flowmeter

  • Kim, Byoung-Chul;Joung, Ok-Jin;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1201-1206
    • /
    • 2003
  • A measurement device for gas flow rate using hot-wire module is developed for the utilization in low-accuracy industrial applications. The module has three wires of measuring and heating, and a bridge circuit is installed to detect electric current through the wire in the module. An amplification of the signal and conversion to digital output are conducted for the online measurement with a personal computer. In addition, temperature distribution in the module is numerically analyzed to examine the measured outcome from the module experiment. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. The experimental relation of measurement and flow agrees with the prediction from the numerical analysis. The outcome of the performance test indicates that the accuracy and reproducibility of the module is satisfactory for the purpose of industrial applications.

  • PDF

Development and Uncertainty Evaluation of Piston Prover (피스톤 푸루버 개발 및 불확도 평가)

  • Choi, Hae-Man;Park, Kyung-Am
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.2 s.19
    • /
    • pp.47-53
    • /
    • 2003
  • The piston prover was developed and the flow measurement uncertainty of this piston prover was evaluated according to ISO/IEC 17025. The laser interferometer, instead of the optical sensors used in the typical provers, was employed in this prover to measure accurately the testing time and the moved distance of the piston. Uncertainty was calculated with evaluation of various uncertainty factors affecting flow measurement. The expanded uncertainty (U) of the piston prover was $1.3{\times}10^{-3}$ (at the confidence level of $95\%$). This evaluation example will be useful in the flow measurement uncertainty determination of other gas flow measurement system.

Permeability Measurement of the Braided Preform in Resin Transfer Molding (고분자 수지 이송 성형에서 브레이드 프리폼의 투과율 계수 측정)

  • Y. K. Cho;Y. S. Song;J. R. Youn
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.65-67
    • /
    • 2002
  • Resin Transfer Molding(RTM) is increasingly used for producing fiber reinforced polymer composites, the resin has to flow a long distance to impregnate the dry fibers. The measure for the resistance of the fiber preform to the resin flow is the permeability of the fiber preform. Permeability is a key issue in the design of molds and processes and in flow modeling. In this study, permeability measurement for braided preform is presented and compared with the permeability calculated numerically. Experimental techniques being used to measure the permeability are also discussed. Measurement is conducted in radial flow test under constant pressure.

  • PDF

Dual-plane Stereoscopic PIV Measurement on the Lobed Jet Mixing Flow

  • SAGA Tetsuo;KOBAYASHI Toshio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.108-122
    • /
    • 2001
  • In a continuing effect to study the mixmg enhancement by large-scale streamwise vortices in lobed mixing flows, an advanced PIV system named as dual-plane stereoscopic PIV system was used in the present study to conduct simultaneous vorticity (all three components) measurement of an air jet exhausted from a lobed nozzle. Unlike 'classical' 2-D PIV system or conventional 'single-plane' stereoscopic PIV system, the dual-plane stereoscopic PIV system used in the present study can obtain the flow velocity (all three components) fields at two spatially separated planes simultaneously. Therefore, it can provide the distributions of all the three components of vorticity vectors instantaneously and simultaneously. The evolution and interaction characteristics of the large-scale streamwise vortices and azimuthal Kelvin-Helmholtz vortices in the lobed jet mixing flow were revealed instantaneously and quantitatively from the measurement results of the dual-plane stereoscopic PIV system. The characteristics of the mixing process in the lobed jet mixing flow were analyzed based on the simultaneous measurement results of the steamwise vorticity and azimuthal Kelvin-Helmholtz vorticity distributions.

  • PDF

A Study on the Precise Measurement of the Performance in the Heating System (발열시스템 열적 성능의 정밀측정에 관한 연구)

  • 최창용;김홍건
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.60-67
    • /
    • 2002
  • A precise measurement of field test was performed to estimate the thermal performance of the forced convection electric air heater by experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to estimate the thermal performance of the tested air heater effectively. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency was obtained accurately as an indication of the tested heating system performance.

Measurement of Gas Concentration and flow Rate Using Hot Wire (열선을 이용한 혼합기체의 농도와 유량의 측정)

  • Kim, Young-Han;Park, Jong-Jueng
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

제너 다이오드를 이용한 공기 유속계측 장치개발

  • 김영재;김희식;조흥근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.496-500
    • /
    • 1996
  • An air flow measurement device is proposed. The thermal characteristic of a semiconductor element is adopted as a cooling parameter of thermal convection rate. The difference between forced convection and natural convection of two Zener diodes results enough difference in temperature. Experiment at various air flow conditions shows the measuring capability of the air flow in a duct. This measuring device has some merits, such as a reliability n hard field condition, simple circuit for signal processing, small volume of the element, less air flow resistance, independance of various ai temperature. The experimental result shows that it is an exact and usefull air flow measurement device.

  • PDF