• Title/Summary/Keyword: flow field characteristics

Search Result 1,759, Processing Time 0.029 seconds

Moisture Permeation Characteristics of Hollow Fiber Membrane Tube for Humidification According to Input Conditions of Wet Steam (습증기 투입 조건에 따른 가습용 중공사막 튜브 수분 투과 특성)

  • CHAE, JONGMIN;YU, SANGSEOK
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.6
    • /
    • pp.620-626
    • /
    • 2018
  • Recently, fuel cell field is receiving much attention as an environmentally friendly energy in the world. Among the various types of fuel cells, in the case of PEMFC, ions move through the membrane in the middle of the unit cell. Therefore, proper moisture is required inside the PEMFC. In the case of membrane type humidifier, flat membrane or hollow fiber membrane is mainly used. Since various parameters can change the performance, the performance investigation has to be carried out with parameters. In this study, water transport of hollow fiber membrane was investigated in terms of principle operating conditions such as temperature and flow rate.

Pyrolysis Behavior of Pulverized Coal Particles at High Heating Rate (미분탄 입자의 고속가열 열분해거동 해석)

  • JANG, JIHOON;HAN, KARAM;YU, GEUN SIL;LIM, HYEON SOO;LEE, WOOK RYUN;PARK, HO YOUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.3
    • /
    • pp.260-268
    • /
    • 2019
  • The pyrolysis characteristics of pulverized coal particle was numerically analyzed with the drop tube furnace. Based on the simulated gas flow field in the drop tube furnace, the particle velocity, temperature and volatile evolution were calculated with the fourth order Runge-Kutta method. The effects of changes in reactor wall temperature and particle diameter on the pyrolysis behavior of coal particle were investigated. The particle heating rate was very sensitive to the reactor wall temperature and particle size, that is, the higher wall temperature and the smaller particle size resulted in the higher heating rate and the consequent quicker volatile evolution.

Analysis of Seawater Transport based on Field Measurements at Pier-bridge between Busan New-port and the Nakdong River Estuary (부산 신항-낙동강 하구역 연결잔교부의 물질수송 해석(I) - 현장조사를 통한 잔교부 해수소통량 평가 -)

  • Lee, Young-Bok;Tawaret, Attapon;Kim, Heon-Tae;Yoon, Han-Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.3
    • /
    • pp.189-195
    • /
    • 2008
  • This study analyzed the characteristics of sea water transport between Busan New-port and the Nakdong River estuary. A current meter was placed on a pier bridge and the current velocity was analyzed to determine the flow direction. Water temperature, salinity, turbidity, and tide were also measured to determine the characteristics of sea water and to describe the tidal current between the two regions. The results indicated that the dominant outflow direction of the ebb tidal current was from the Nakdong River estuary to Busan New-port. Conversely, during a flood tide, the dominant direction was from Busan New-port to the Nakdong River estuary. The maximum current speed during the first and second field measurements was about 13.18 and 30.80 cm/ sec, respectively. During the first field measurement, the total volume of sea water transport was $184.71\;m^3/sec$ and the residual volume transport was $+59.74\;m^3/sec$. By contrast, during the second field measurement, the respective values were $331.15\;m^3/sec$ and $28.88\;m^3/sec$.

  • PDF

Condensation processes in transonic two-phase flows of saturated humid air using a small-disturbance model (미교란 모델을 이용한 포화 습공기 천음속 2상 유동에서의 응축현상)

  • Lee, Jang-Chang;Zvi Rusak
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.23-29
    • /
    • 2003
  • Transonic two-phase flow of Saturated humid air, in which relative humidity is 100%, with various condensation processes around thin airfoils is investigated. The study uses an extended transonic small-disturbance(TSD) model of Rusak and Lee [11, 12] which includes effects of heat addition to the flow due to condensation. Two possible limit types of condensation processes are considered. In the nonequilibrium and homogeneous process, the condensate mass fraction is calculated according to classical nucleation and droplet growth rate models. In the equilibrium process, the condensate mass fraction is calculated by assuming an isentropic process. The flow and condensation equations are solved numerical1y by iterative computations. Results under same upstream conditions describe the flow structure, field of condensate, and pressure distribution on airfoil's surfaces. It is found that flow characteristics, such as position and strength of shock waves and airfoil’s pressure distribution, are different for the two condensation processes. Yet, in each case, heat addition as a result of condensation causes significant changes in flow behavior and affects the aerodynamic performance of airfoils.

Technical Consideration for Production Data Analysis with Transient Flow Data on Shale Gas Well (셰일가스정 천이유동 생산자료분석의 기술적 고려사항)

  • Han, Dong-kwon;Kwon, Sun-il
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.1
    • /
    • pp.13-22
    • /
    • 2016
  • This paper presents development of an appropriate procedure and flow chart to analyze shale gas production data obtained from a multi-fractured horizontal well according to flow characteristics in order to calculate an estimated ultimate recovery. Also, the technical considerations were proposed when a rate transient analysis was performed with field production data occurred to only $1^{st}$ transient flow. If production data show the $1^{st}$ transient flow from log-log and square root time plot analysis, production forecasting must be performed by applying different method as before and after of the end of $1^{st}$ linear flow. It is estimated by an area of stimulated reservoir volume which can be calculated from analysis results of micro-seismic data. If there are no bottomhole pressure data or micro-seismic data, an empirical decline curve method can be used to forecast production performance. If production period is relatively short, an accuracy of production data analysis could be improved by analyzing except the early production data, if it is necessary, after evaluating appropriation with near well data. Also, because over- or under-estimation for stimulated reservoir volume could take place according to analysis method or analyzer's own mind, it is necessary to recalculate it with fracture modeling, reservoir simulation and rate transient analysis, if it is necessary, after adequacy evaluation for fracture stage, injection volume of fracture fluid and productivity of producers.

An experimental study on vortex formation in groyne fields according to groyne spacing and installed angles (수제간격과 설치각에 따른 수제역내 와형성에 대한 실험 연구)

  • Kang, Joongu;Kim, Sungjoong
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.35-48
    • /
    • 2018
  • Groynes are installed generally to protect the riverside or the river bank from the erosion caused by water flows by controlling the flow direction and velocity in rivers. In the past, groynes were used to secure enough depth of water in canals. As there has been a growing interest in river restoration and the natural river maintenance since 2000, groynes are proposed as a major environmental hydraulic structure because the flow control and various river bed conditions around the groyne can contribute to habitat functions. Groynes are typically installed in a series. In designing groyne series, groyne spacing is an important factor because the flow changes in the main canal and the flow inside the groyne area occurs variably depending on the groyne spacing. This study provide information to determine the groyne spacing suitable for the purpose of the groyne by examining the flows that variably changes according to the groyne spacing and angle in the recirculation zone of the groyne field. In particular, the formation of vortex, the location of vortex core and the water flow near the river bank, all of which occur in the recirculation zone inside the groyne area, were mainly analyzed to examine the flow characteristics near the river bank that influences the safety of the river bank area. The results of the experiment will serve as important basic data to examine changes in the river bed inside the groyne area as well as the safety of river banks following the installation of groyne series.

Numerical analysis on thermal-fluidic characteristics of the magnetic fluid in a cavity using GSMAC (GSMAC법을 이용한 밀폐된 정방형관내 자성유체의 열-유동 특성에 관한 해석적 연구)

  • Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.997-1002
    • /
    • 2013
  • The article is aiming to investigate the thermal-fluidic characteristics of magnetic fluid in a cavity using GSMAC (generalized-simplified marker and cell method). The transport equations of the magnetic fluid are including the continuity equation, momentum equation and energy equation for natural convection and Maxwell equation and magnetization equation of magnetite nano-sized particles motion. In addition, the heat transfer characteristics such as temperatures and Nusselt numbers and flow characteristics such as streamlines and isotherms of the magnetic fluid were analyzed with the intensity and direction of the magnetic fields. As a result, the thermal-fluidic characteristics of the magnetic fluid in a cavity were could be controlled by the intensity and direction of the magnetic fields.

An Experimental Study on Power Transmission Characteristics Flow Rate in Fluid Couplings (유체커플링에서 유량과 동력전달특성에 관한 실험적 연구)

  • Pak, Yong-Ho;Moon, Dong-Cheol;Yum, Man-Oh
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.11
    • /
    • pp.27-35
    • /
    • 1995
  • The fluid coupling combined with a pump and a turbine have many merits compared with other couplings, their uses are increesing rapidly in various industrial fields at home and abroad in pursuit of high-speed more efficiency durability of various mechanic devices. The authorities concerned have recognized the improtance of the fluid coupling and supported its developement and now some trial products began to show up. As the structrue and characteristics of the fluid coupling have little similarity to other kinds of couplings and its fluid behavior is unique, so its characteristic analysis is expected to be difficult. Until now no satisfactory study on the characteristics of the fluid coupling seems to have been conducted at home, so a study on this field needs to be done urgently. The purpose of this research is to construct the experimental test set-ups and establish a series of performance test program for the domestically developed fluid couplings and to provide a software to store and utilize these experimental data which can be used to improve the performance of the fluid coupling and solve on the job problems confronted in operation. The performance test consists of taking measurment of torque, rpm and efficiency of the fluid coupling for three different amount of working fluid inside with various loads to the output shaft and finally infestigating the torque, rpm and efficiency characteristics of the fluid coupling with respect to these parameters. The results of this study can contribute valuable references to the development of variable speed fluid coupling and torque converter currently pursued by the domestic industry.

  • PDF

The Characteristic Calculation of the Wake through Cylinders by Vortex Method (와법을 이용한 원주군을 지나는 후류의 특성 계산)

  • Ro, Ki-Deok;Oh, Se-Kyung;Byun, Yong-Sue
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.76-83
    • /
    • 2010
  • The Characteristics of the flow field through cylinders with in-line and staggered arrangements were calculated by vortex method. Vortex distributions and velocity profiles around the cylinders with in-line and staggered arrangements were simulated at the pitch ratio of Pt/D=1.25~2.0 and Reynolds number of Re=$4.0{\times}10^1{\sim}4.0{\times}10^4$. As the results the vortices of clockwise at the upper separation point cylinder and the vortices of anticlockwise at the lower separation point of each cylinder were generated at both in-line and staggered arrangements. The generation of the reverse flow in the rear region of the cylinders was caused by the pitch ratio and Reynolds number, the boundary region was at the pitch ratio of Pt/D=1.5 and Reynolds number of Re=$4.0{\times}10^2{\sim}4.0{\times}10^3$ in case of in-line arrangement and was at the pitch ratio of Pt/D=1.4 and Reynolds number of Re=$4.0{\times}10^1{\sim}4.0{\times}10^2$ in case of staggered arrangement.

Numerical Analysis and Experimental Investigation of Duct Flows of an MHD Propulsion System (사각형의 MHD 추진 덕트 내부유동에 관한 수치해석 및 실험적 연구)

  • J.W. Lee;S.J. Lee;C.M. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.1
    • /
    • pp.83-93
    • /
    • 1995
  • A numerical and experimental investigation on the flow characteristics in the rectangular duct of an MHD propulsion system has been carried out. In numerical analysis, three-dimensional, steady-state, viscous, incompressible electrically conducting fluid flow under the influence of uniformly applied magnetic and electric fields was treated using a finite-difference technique. It was found from the numerical study that when the Lorentz force is weak, the typical parabolic velocity profile under a laminar flow condition changes to an M shaped profile near the electrode region and that the pressure increases linearly from the inlet toward the outlet of the MHD duct under constant electro-magnetic field. In experiment, thrust of the MHD propulsion system can be controlled easily by varying electrode current. The measured pressure gradient along the MHD duct is proportional to the Lorentz force, which is in agreement with the numerical results.

  • PDF