• Title/Summary/Keyword: flow control function

Search Result 612, Processing Time 0.032 seconds

Determination of Eccentric Axis for Pump Control Valve Using the Characteristic Function (특성함수를 이용한 펌프 제어 밸브의 편심축 결정)

  • Shin, Myung-Seob;Yi, Sang-Il;Park, Gyung-Jin;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.43-49
    • /
    • 2008
  • The pump control valve is a butterfly valve that has an eccentric rotating axis. It is not only used as a butterfly valve to control the flow rate or pressure, but also as a check valve to prevent backward flow. A new design method of eccentric rotating axis is proposed to design the valve. The height of the rotating axis is determined through flow field analysis. A general purpose of computational fluid dynamics software system, Fluent is used to simulate the fluid flow. Flow field analysis is performed for various heights of the rotating axis and different opening angles of the valve. A characteristic function is defined for estimating the flow characteristics based on the results of flow field analysis. The characteristic function is defined in order to determine the height of the rotating axis. An optimization problem with a characteristic function is formulated to determine the amount of eccentricity. The height of the Totaling axis of the valve is determined through solving the optimization problem.

Multi-function Control of Hydraulic Variable Displacement Pump with EPPR Valve (전자비례감압밸브를 이용한 가변용량형 유압펌프의 다기능 제어)

  • Jung, Dong-Soo;Kim, Hyong-Eui;Kang, E-Sok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.160-170
    • /
    • 2006
  • If hydraulic pump controlled by mechanical type regulator has more than one control function, the construction of regulator will be very complicated and control performance falls drastically. It is difficult to have more than one control function for hydraulic pump controlled by electronic type hydraulic valve due to the inconsistency of controllers. This paper proposes a multi-function control technique which controls continuously flow, pressure and power by using EPPR(Electronic Proportional Pressure Reducing) valve in swash plate type axial piston pump. Nonlinear mathematical model is developed from the continuity equation for the pressurized control volume and the torque balance for the swash plate motion. To simplify the model we make the linear state equation by differentiating the nonlinear model. A reaction spring is installed in servo cylinder to secure the stability of the control system. We analyze the stability and disturbance by using the state variable model. Finally, we review the control performances of flow, pressure and power by tests using PID controller.

The Analysis and Control of Compressed Gas Discharging System (압축가스 방출 유압시스템 해석 및 제어)

  • 장웅락;김정관;한명철;정찬희;박인기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.458-462
    • /
    • 2004
  • The hydraulic system for discharging compressed gas is composed of compressor tank, proportional flow control servo valve, expulsion spool valve and discharging tube. Purpose of this study is to control of expulsion spool valve. First, we analyzed the hydraulic system. The flow control servo valve is modeled as a 2nd order transfer function and friction force of the expulsion spool valve is modeled as nonlinear model with stribeck effect. However, it is difficult to include the flow reaction force in modeling. So, we exchanged from the simplified flow reaction force of the compressed gas affection into the flow analysis code written in FORTRAN code. Our simulation of the oil pressure system for discharging gas used MATLAB/Simulink. So, we realized 'Level -2 S-Function Fortran' to cooperate for MATLAB/Simulink and FORTRAN code. PD controller is selected to control in this system. Simulation results show that with given conditions the controllers give a good tracking performance.

  • PDF

Integrate Processing Scheme of Flow Control Language (흐름 제어 언어의 통합 처리)

  • Kim, Tae-Wan;Chang, Chun-Hyon
    • The KIPS Transactions:PartD
    • /
    • v.11D no.2
    • /
    • pp.415-422
    • /
    • 2004
  • Automation systems improve the productivity of works which relate to product design, facilities management, fault processing and quality evaluation. In these systems, the description language for monitoring and control process is called new control language. These are five flow control languages : IL, ST, FBD, SFC and LD. IL and ST are based on left form. FBD, SFC and LD are based on graphic form. Generally, a software which monitors and controls a system is allowed to use just one flow control language. It is impossible to use more than two languages for simulation in the same system environment. In this paper, we analyzed the characteristics of flow control languages and the process of programming in the legacy system. In addition, for the Integrated processing of languages, we propose Extended ST based on the high-level ST language. Based on this research, we implement a graphical language editor and EST-IL convertor. The graphical language editor makes sequence rules, and converts graphical language into EST. EST-IL convertor has a function to convert EST into IL which is similar to assembly language. As the result of this paper, we present a scheme which integrates all the flow control language processing based on IL.

Flow Rate Control System Design for the Industrial Valve (산업용 밸브의 유량제어 시스템 설계)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.387-392
    • /
    • 2020
  • This paper proposes a flow-rate control system for industrial valves. Industrial valves are used in piping systems to control the flow rate and pressure. In general, valves used in pipelines are classified into globe valves, butterfly valves, and ball valves according to the shape. Motor, hydraulic, and pneumatic systems are used for operating valves. The flow meter should measure the flow rate when configuring the flow-rate control system. On the other hand, because the flow rate of the valve can be expressed by flow coefficient, a control scheme is proposed using the pressure deviation, which measures at the front and rear of the valve. The transfer function for the valve, according to the control input, was estimated using the signal compression method. Based on the induced transfer function, the disturbance observer was designed to improve the command following the performance of the valve stem. The performance of the proposed control method is compared with the flow-rate control result using the flow meter used.

A Study of Attacks to Bypass CFI on Android Application Environment (안드로이드 애플리케이션 환경에서 CFI 우회 공격기법 연구)

  • Lee, Ju-yeop;Choi, Hyoung-kee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.5
    • /
    • pp.881-893
    • /
    • 2020
  • CFI(Control Flow Integrity) is a mitigation mechanism that protects programs by verifying control flows. IFCC(Indirect Function Call Checks) and SCS(Shadow Call Stack), CFI supported by LLVM Clang compiler, were introduced to protect applications in Android. IFCC protects function calls and SCS protects function returns. In this paper, we propose attacks to bypass CFI on the application environment with IFCC and SCS. Even if IFCC and SCS were applied to user applications, it was confirmed that there were many code segments not protected by IFCC and SCS in the application memory. We execute code in CFI unprotected segments to construct 1) bypassing IFCC to call a protected function, 2) modulating return address via SCS bypass. We identify code segments not protected by IFCC and SCS in Android10 QP1A. 191005.007.A3. We also implement proof-of-concept exploits to demonstrate that modulation of control flow is possible in an environment where IFCC and SCS are applied.

Design and Implementation of a Mail Browser that can control Data-Flow on the Web (Web에서 데이터 흐름제어가 가능한 Mail Browser의 설계 및 구현)

  • Park, Gyu-Seok;Kim, Seong-Hu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.10
    • /
    • pp.2752-2763
    • /
    • 1999
  • On account of the text based mail system has it's limit to support multimedia applications, GUI based mail system platform was developed to control document flow and automatize information process. The existing mail systems's to transmit data must need additional functions to automate document flow control. The platform of document flow control is deeply related to EDMAS(Electronic document Management System), workflow, Electronic Banking, DMS(Document Management System) automation, so it needs an ability to control proper data and document correctly. To resolve this problems, we are need of browser and engine to design work flow and to control documents flow. In this paper, we develope a mail browser to design document flow by follow user's requirements. This system can generate executive script code for document flow, and we add the function of workflow and process management to automatize the document flow in this system, and then we implement this Data flow engine.

  • PDF

Application of energy function control strategy to VSC based UPFC Model (전압원 컨버터 기반의 UPFC 모델에 대한 에너지 함수 제어전략의 적용)

  • Kook, Kyung-Soo;Oh, Tae-Kyoo;Chun, Yeong-Han;Kim, Hak-Man;Kim, Tai-Hyun;Jeon, Jin-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.259-261
    • /
    • 2000
  • UPFC(Unified Power Flow Controller) consists of two voltage sourced converter(VSC)s inserted into AC system through series and parallel coupling transformer, where two VSCs are linked by capacitor at DC-side. Since VSC acts as an AC voltage source behind a reactance, where both magnitude and phase angle of the source are controllable, UPFC can be represented by the equation related to input-output relation of two VSCs. Voltage control of DC-link capacitor provides the path of real power flow between two VSCs. While UPFC is controlled for maintaining the given reference value in steady state, it should be controlled for damping power oscillation in dynamics. For such a control objective, the control strategy based on the energy function was proposed and has been shown to be effect and robust for damping power oscillation of power system. In this paper, UPFC model based on the VSC was analysed and applied to power-flow control and stability analysis. The control strategy based on the energy function is adopted for damping power oscillation of power system. The effectiveness of proposed control strategy was verified by simulation study

  • PDF

Design of Intelligent Servocontroller for Proportional Flow Control Solenoid Valve with Large Capacity (지능형 대용량 비례유량제어밸브 서보컨트롤러 설계)

  • Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2011
  • As the technologies of electronic device have advanced these days, most of mechanical systems are designed with electronic control unit to take advantage of control parameter adaption to operating conditions and firmware flexibilities as well. On-board diagnosis, which detects the system malfunction and identifies potential source of error with its own diagnostic criteria, and fail-safe that can switch the mode of operation in view of recognized error characteristics enables easy maintenance and troubleshooting as well as system protection. This paper dealt with the development of diagnosis and fail-safe function for proportional flow control valve. All type of errors related to valve control system components are investigated and assigned to a specific hexadecimal codes. Cumulative error detection algorithm is applied in order for the sensitivity and reliability to be appropriate. Embedded simulator which runs simultaneously with system program provides the virtual error simulation environment for expeditious development of error detection algorithm. The diagnosis function was verified both with solenoid valve and embedded simulator test and it will enhance the valve control system monitoring function.

Structural and Layout Design Optimization of Ecosystem Control Structures (2) -Characteristics of Subsidence and Burial of Artificial Habitat due to Sediment Transport in Flow Field- (생태계 제어 시설물의 설계 및 배치 최적화(2) -흐름장에서의 인공어초의 침하 및 매몰 특성-)

  • RYU Cheong-RO;KIM Hyeon-Ju;LEE Han-Su;SHIN Dong-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.1
    • /
    • pp.139-147
    • /
    • 1997
  • Sediment transport around artificial habitat which is induced by the change ol flow due to installation of the structure plays a role not only as a defect function of subsidence and burial but also bottom-environment control function. This study examined the characteristics of local scouring and deposition with sediment sizes, current velocities and installation direction of artificial habitat in flow field. Resultant subsidence and burial processes are investigated and discussed with Reynolds number. Together with sediment number and dimensionless time elapse, prediction formulas are established by combining these relationships. Bottom control function as cultivating effects is discussed with installation direction, and applicability of countermeasures is compared and stone pavement method is recommended.

  • PDF