• Title/Summary/Keyword: flow cell

Search Result 3,127, Processing Time 0.026 seconds

Numerical Analysis of Incompressible and Compressible Flow Around a Butterfly Valve (버터플라이 벨브 주위의 비압축성 및 압축성유동 특성에 대한 수치해석)

  • 이종욱;이두환;최윤호
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2002
  • In this paper, incompressible and compressible flow characteristics around the butterfly valve have been investigated. In order to simplify the problem, a flat disk valve with various valve disk angles and pressure ratios is considered in the present calculations. It was found that as the disk angle increases, the stagnation point on the front surface of the disk moves to the center of the surface and the inflow velocity decreases. The maximum flow velocity occurs at the downstream of throat because of the formation of vents contracta. As the pressure ratio decreases, compressibility effects increase and the jet formed between the throttle body wall and the disk edge becomes supersonic. This flow also builds up as a shock cell structure. The increase of disk angle and pressure ratio makes the mass flow at the inlet decrease, while the increase of disk angle and the decrease of pressure ratio make the pressure loss coefficient increase.

Effects of 3D Flow-Channel Configurations on the Performance of PEMFC using Computational Fluid Dynamics (전산유체역학을 이용한 PEMFC의 성능에 대한 3차원 유로 구조의 영향)

  • Han, Kyoung-Ho;Yoon, Do Young
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.847-853
    • /
    • 2016
  • Here has been examined a 3-dimensional computational fluid dynamics (CFD) modeling in order to investigate the performance analysis of proton exchange membrane (PEM) fuel cells with serpentine flow fields. The present CFD model considers the isothermal transport phenomena in a fuel cell involving mass, momentum transport, electrode kinetics, and potential fields. Co-current flow patterns for a PEMFC are considered for various geometries in the single straight cell. Current density distribution from the calculated distribution of oxygen and hydrogen mass fractions has been determined, where the activation overpotential has been also calculated within anode and cathode. CFD results showed that profiles differ from those simulations subjected to each the calculated activation overpotential. It is interesting that the present serpentine flow field shows the specific distribution of current density with respect to the aspect ratio of depth to width and the ratio of reaction area for various serpentine geometries. Simulation results were considered reasonable with the other CFD results reported in literature and global comparisons of the PEMFC model.

Experimental Study of Performance and Bubble Pattern of Air-Lift Pumps with Various Tube Diameters and Submergence Ratios (공기부양 펌프의 관직경과 잠수비 변화에 따른 기포 형상과 성능에 관한 실험적 연구)

  • Kim, Seung Hwan;Sohn, Chae Hoon;Hwang, Jun Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.837-845
    • /
    • 2013
  • An airlift pump can be used to pump liquids and sediments within itself, which cannot easily be pumped up by a conventional method, by using the airlift effect. This characteristic of the airlift pump can be exploited in a DCFC (Direct Carbon Fuel Cell) so that molten fuel with high temperature may be carried or transported. The basic characteristics of airlift are investigated. A simple system is constructed, where the reservoir is filled with water, a tube is inserted, and air is supplied from the bottom of the tube. Then, water is lifted and its flow rate is measured. Bubble patterns in the tube are observed in a range of air flow rates with the parameters of the tube diameter and submergence ratio, leading to four distinct regimes. The pumping performance is predicted, and the correlation between the supplied gas flow rate and the induced flow rate of water is found.

Research on Acceleration Mechanism of Inflight Particle and Gas Flow Effect for the Velocity Control in Vacuum Kinetic Spray Process (진공상온분사(VKS) 공정에서의 비행입자 가속 기구 및 속도제어를 위한 가스 유량 효과에 관한 연구)

  • Park, Hyungkwon;Kwon, Juhyuk;Lee, Illjoo;Lee, Changhee
    • Korean Journal of Materials Research
    • /
    • v.24 no.2
    • /
    • pp.98-104
    • /
    • 2014
  • Vacuum kinetic spray(VKS) is a relatively advanced process for fabricating thin/thick and dense ceramic coatings via submicron-sized particle impact at room temperature. However, unfortunately, the particle velocity, which is an important value for investigating the deposition mechanism, has not been clarified yet. Thus, in this research, VKS average particle velocities were derived by numerical analysis method(CFD: computational fluid dynamics) connected with an experimental approach(SCM: slit cell method). When the process gas or powder particles are accelerated by a compressive force generated by gas pressure in kinetic spraying, a tensile force generated by the vacuum in the VKS system accelerates the process gas. As a result, the gas is able to reach supersonic speed even though only 0.6MPa gas pressure is used in VKS. In addition, small size powders can be accelerated up to supersonic velocity by means of the drag-force of the low pressure process gas flow. Furthermore, in this process, the increase of gas flow makes the drag-force stronger and gas distribution more homogenized in the pipe, by which the total particle average velocity becomes higher and the difference between max. and min. particle velocity decreases. Consequently, the control of particle size and gas flow rate are important factors in making the velocity of particles high enough for successful deposition in the VKS system.

End-to-End Congestion Control of High-Speed Gigabit-Ethernet Networks based on Smith's Principle

  • Lee, Seung-Hyub;Cho, Kwang-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.101-104
    • /
    • 2000
  • Nowadays, the issue of congestion control in high-speed communication networks becomes critical in view of the bandwidth-delay products for efficient data flow. In particular, the fact that the congestion is often accompanied by the data flow from the high-speed link to low-speed link is important with respect to the stability of closed-loop congestion control. The Virtual-Connection Network (VCN) in Gigabit Ethernet networks is a packet-switching based network capable of implementing cell- based connection, link-by-link flow-controlled connection, and single- or multi-destination virtual connections. VCN described herein differ from the virtual channel in ATM literature in that VCN have link-by-link flow control and can be of multi-destination. VCNs support both connection-oriented and connectionless data link layer traffic. Therefore, the worst collision scenario in Ethernet CSMA/CD with virtual collision brings about end-to-end delay. Gigabit Ethernet networks based on CSMA/CD results in non-deterministic behavior because its media access rules are based on random probability. Hence, it is difficult to obtain any sound mathematical formulation for congestion control without employing random processes or fluid-flow models. In this paper, an analytical method for the design of a congestion control scheme is proposed based on Smith's principle to overcome instability accompanied with the increase of end-to-end delays as well as to avoid cell losses. To this end, mathematical analysis is provided such that the proposed control scheme guarantees the performance improvement with respect to bandwidth and latency for selected network links with different propagation delays. In addition, guaranteed bandwidth is to be implemented by allowing individual stations to burst several frames at a time without intervening round-trip idle time.

  • PDF

Pressure Drop Analysis on Filling of Hydrogen Fuel Cell Vehicles (수소연료전지 차량 충전에서의 압력강하 분석)

  • Hyo Min Seo;Byung Heung Park
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.38-47
    • /
    • 2023
  • In the hydrogen filling process, hydrogen flows by the pressure difference between the supply pressure at a filling station and a storage tank in the vehicle, and the flow rate depends on the pressure difference. Therefore, it is essential to consider the pressure drop of hydrogen occurring during the filling process, and the efficiency of the hydrogen filling process can be improved through its analysis. In this study, the pressure drop was analyzed for a hose, a nozzle/receptacle coupling, a pipe, and a valve in a filling line. The pressure drops through hose and pipe, the nozzle,receptacle coupling, and the valve were calculated by using a equation for a straight conduit, a flow nozzle formula, and a gas flow respectively. In addition, as a result of comprehensive analysis of the pressure drop effect occurring in each component, it was found that the factor that has the greatest influence on the pressure drop in the entire filling line is the pressure drop through the valve. This study can be used to develop a model of the hydrogen filling process by analyzing hydrogen flow including hydrogen filling in the future.

The Development and Performance Evaluation of a Cyclone to Remove Hot Particulate from a Contaminated Hot Cell (Hot Cell 내에 오염된 고방사능분진 제거를 위한 사이클론 개발 및 성능평가)

  • Kim Gye-Nam;Won Hui-Jun;Choi Wang-Kyu;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.217-226
    • /
    • 2006
  • The structural and contamination characteristics of hot cells at KAERI were investigated. The SEM results showed that the size of the hot particulate on the inner surface of the hot cell ranged from 0.2 to $10{\mu}m$. It was found that an inlet flow rate of 15 m/sec was suitable for this developed cyclone with a 49 mm optimum vortex finder length. The results showed that the collection efficiency was about 85% for $3{\mu}m$ particles. The collection efficiency didn't show a sharp increase when the inlet flow rate was faster than 15m/sec. When the temperature of the inlet flow gas was increased, the collection efficiency of the cyclone was slightly decreased. The larger the vortex finder length was, the higher the pressure drop in the cyclone was. The cut size diameter decreased with an increment of the Reynolds number. It was established that the flow in the cyclone was a turbulent flow on the basis of the Reynolds number and this turbulent flow caused a pressure drop in the cyclone. $Stk^{1/2}_{50}$ decreased with increasing values of the Reynolds number and it gradually approached a constant value at a higher value of the Reynolds number Namely, $Stk^{1/2}_{50}$ approached approximately 0.045 between 6000 and 8000 of the Reynolds number.

  • PDF

Single Cell Dissociation Methods for Flow Cytometric Cell Death Analysis of Hypoxia-Ischemia Injured Newborn Rat Pup Brain (저산소성 허혈성 뇌손상이 유발된 신생백서에서 단일세포의 분리)

  • Hwang, Jong Hee;Sung, Dong Kyung;Choi, Chang Won;Kang, Saem;Chang, Yun Sil;Park, Won Soon;Lee, Munhyang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.5
    • /
    • pp.545-550
    • /
    • 2005
  • Purpose : Newborn brain tissue has to be dissociated into a single cell suspension for flow cytometric analysis of cell death during hypoxia-ischemia. Thus the development of a method to dissociate cells from the brain tissue with least damage and maintenance of membrane and antigen integrity remains the challenge for the in vivo application of this technique. We evaluated the efficacy of mechanical or enzymatic (collagenase or tryspin) methods of brain tissue disaggregation. Methods : The extent of the damage to the plasma membrane and loss of the characteristics of the membrane induced with each dissociation method was determined by comparing the flow cytometric results labeled with both fluorescent annexin V and propidium iodide of the newborn rat pup brain tissue in the control group (n=10) and in the 48-hour after hypoxia-ischemia group (n=10). Results : In the control group, the cell percentage of damaged, apoptotic and necrotic cells of both hemispheres with the mechanical dissociation method was significantly increased compared to the trypsin or collagenase method. In the 48-hour after hypoxia-ischemia group, the cell percentage of apoptotic and necrotic cells of the right hemisphere with the collagenase method significantly increased, and live cells significantly decreased compared to the left hemisphere, control group. Although the same trend was observed, the extent of alterations made with the trypsin method was significantly less compared to the collagenase method. Conclusion : The dissociation of neonatal brain tissue for flow cytometric analysis with collagenase was most efficacious with the least cell damage and preservation of the plasma membrane characteristics.