• 제목/요약/키워드: flow angle

검색결과 2,907건 처리시간 0.034초

Hydro-Reactive 엔진의 산화제 분사각도에 따른 연소특성에 대한 연구 (Effects of Oxidizer Inject Angle on Combustion Characteristics in Hydro-Reactive Engine)

  • 원종한;이성남;백승욱;황창환;김경무
    • 한국연소학회지
    • /
    • 제19권2호
    • /
    • pp.1-7
    • /
    • 2014
  • In this study, the variation of the flow field in Hydro-reactive engine combustor was numerically studied through 2-dimensional axisymmetric model with aluminum and heated water vapor. For calculating all velocity fields, compressible Navier-Stokes equation was used with Pre-conditioning. AUSM+up(p) method was used to exactly calculate mass flow in the control volume. As using SST model that is a turbulent model, the result had high accuracy for free stream and the flow near the wall. The effects of the temperature, variation of the flow field and distribution of chemical products on inject angle of heated water vapor were studied.

산업용 Turbo형 송풍기의 Cutoff 각도에 따른 유동특성 (Flow Characteristics due to Cutoff angle of Turbo-Fan for Industries)

  • 윤지훈;정인국;이중섭;서정세
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.91-96
    • /
    • 2011
  • This study aims to analyze the flow characteristics of turbo-fan which is applied to the industrial field. Numerical analysis has been carried out to investigate the pulsation behavior of exhaust air flown out turbo fan by rotating impeller with constant speed. Moving mesh technique is proved as time-accurate solution for the flow inside impeller. As numerical results come within the error range of 1% by comparing with theoretical results, the numerical analysis can be verified. Cutoff angle has large influence on the amplitude of pulsation and the least pulsation of flow can be generated by the cutoff angle of $20^{\circ}$.

배기용 Fan Scroll에 대한 연구 (A Study on the Fan and Scroll for Ventilation)

  • 송성배;박성일;이준세
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.402-406
    • /
    • 2000
  • In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

  • PDF

유량분배 매니폴드의 유출유동에 대한 출구형상 영향 해석 (EFFECT OF EXIT SHAPE ON TURBULENT OUTFLOWS IN A DISTRIBUTION MANIFOLD)

  • 이준우;박태선
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.73-79
    • /
    • 2014
  • Three-dimensional turbulent flows of a distribution manifold are studied by a turbulence model. To investigate the geometrical effects of the manifold, the length and area of exit port are changed. From the results, flow structures related to the outflow uniformity are examined and the deparure angles are obtained. The exit configuration depending on the departure angle has advantages to the outflow uniformity. That is, the decreased exit area in the streamwise direction improves the uniformity of exit flow. For the uniform effusion, the change of exit port by departure angle is more effective them the change of exit area.

경사면에서의 리뷸릿 유동에 관한 연구 (A Study of Rivulet Flow on an Inclined Solid Surface)

  • 김진호;김호영;강병하;이재헌
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.1042-1048
    • /
    • 2001
  • When a liquid is supplied through a nozzle onto a relatively non-wetting inclined solid surface, a narrow rivulet forms. This work provides novel physical insights into the following phenomena in the rivulet flow that have not been well understood to date. Firstly, the fundamental mechanism behind the transition of a linear rivulet to a droplet flow is investigated. The experiments show that the droplet flow emerges due to the necking of a liquid thread near the nozzle. Based on the observation, it is argued that when the axial velocity of a liquid is slower than the retraction velocity of its thread, the bifurcation of the liquid thread occurs, and this argument is experimentally verified. Secondly, a discussion on the curled motion of a meandering rivulet is given. This study proposes the contact angle hysteresis as a primary origin of the centripetal force that enables the rivulet\`s curved motion. A simple scaling analysis based on this assumption predicts a radius of curvature which agrees with the experimental observation.

  • PDF

Inviscid Rotational Flows Near a Corner and Within a Triangle

  • Suh, Yong-Kweon
    • Journal of Mechanical Science and Technology
    • /
    • 제15권6호
    • /
    • pp.813-820
    • /
    • 2001
  • Solutions of inviscid rotational flows near the corners of an arbitrary angle and within a triangle of arbitrary shapes are presented. The corner-flow solutions has a rotational component as a particular solution. The addition of irrotatoinal components yields a general solution, which is indeterminate unless the far-field condition is imposed. When the corner angle is less than 90$^{\circ}$the flow asymptotically becomes rotational. For the corner angle larger than 90$^{\circ}$it tends to become irrotational. The general solution for the corner flow is then applied to rotational flows within a triangle (Method I). The error level depends on the geometry, and a parameter space is presented by which we can estimate the error level of solutions. On the other hand, Method II employing three separate coordinate systems is developed. The error level given by Method II is moderate but less dependent on the geometry.

  • PDF

삼각봉을 지나는 층류유동에 대한 입구유동각도 변화의 영향 (EFFECTS OF INFLOW ANGLE ON LAMINAR FLOW PAST A TRIANGULAR CYLINDER)

  • 박태선
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.22-28
    • /
    • 2011
  • Laminar Flow over an equilateral triangular cylinder is studied for several inflow angles. Under an uniform flow of $Re_d$=50,75,100,125,150, the triangular cylinder is rotated by ${\theta}$=$0^{\circ}$,$15^{\circ}$,$30^{\circ}$,$45^{\circ}$,$60^{\circ}$,$75^{\circ}$,$90^{\circ}$,$105^{\circ}$. The governing equations are solved by the PISO algorithm based on the finite volume method of the unstructured grid system. The effects of the inflow angle on the vortex-shedding flows are investigated. The Strouhal number shows a minimum at ${\theta}$=$60^{\circ}$. It is closely related to the variation of pressure and flow structure induced by the movement of separation points.

Numerical Analysis on the Effect of Parameters that Affect the Flow Rate through the Tunnel with Jet Fan Ventilation System

  • Kim, Sa-Ryang;Hur, Nahmkeon;Kim, Young-Il;Kim, Ki-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.178-187
    • /
    • 2003
  • In this study, ventilation flow rate and pressure rise through a tunnel are simulated numerically using computational fluid dynamics (CFD) for various conditions such as roughness height of the surface of tunnel, swirl angle and hub/tip ratio of jet fan, and entrance and exit effects. By using a modified wall function, friction factor can be predicted with respect to the Moody chart within 10% of error for the circular pipe flow and 15% for the present tunnel. For more accurate design, the effect of the swirl angle and hub/tip ratio of jet fan, which is not included in the theoretical equation of pressure rise by jet fan needs to be considered.

디퓨저 베인각의 변화에 따른 압축기 성능 특성 (Compressor Performance with Variation of Diffuser Vane Inlet Angle)

  • 배명형;신유환;김광호;김진형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.55-60
    • /
    • 1999
  • A centrifugal compressor was tested with three different diffusers with plate vanes. The vane inlet angle was varied from 15 to 30 dog. The higher static pressure rises are obtained with lower vane stagger angle. In the stable region the static pressure field in vaneless space is very sensitive to flow rate. The impeller has a stabilizing effect over the whole stable operating range. The diffuser has a stabilizing effect at high flow rate but is destabilizing at low flow rate.

  • PDF

스크롤 선회에 따른 압축 공간내의 유동 특성 (Flow Characteristics inside a Compression Chamber due to the Orbiting Motion of a Scroll)

  • 강동진;전현주;오미애
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.251-256
    • /
    • 2003
  • The detailed flow characteristics inside a compression chamber due to the orbiting motion of a scroll is studied numerically. The orbiting motion of a scroll is modelled at 7 orbiting angles. At each orbit angle, the central compression chamber is modelled. All computations are carried by using an in-house code. It is based on the SIMPLE algorithm. Computation results show that the flow structure inside the compression chamber is dependent on the orbit angle. The pressure variation inside the compression chamber also shows great dependence on the orbit angle. The pressure variation shows local maxima when the orbiting motion of a scroll directs toward the center of the compression chamber.

  • PDF