• Title/Summary/Keyword: flow analysis

Search Result 17,873, Processing Time 0.044 seconds

Modeling for Debris Flow Behavior on Expressway Using FLO-2D (FLO-2D를 이용한 고속도로에서의 토석류 거동 모델링)

  • Lim, Jae-Tae;Kim, Byunghyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.263-272
    • /
    • 2019
  • This study demonstrates the applicability of the FLO-2D for the influence analysis of the debris flow on expressway. To do this, the behavior of debris flow on the expressway was reproduced by applying the FLO-2D to actual generated debris flow. The study area is a part of the Deokyusan Service Area on the Daejon-Jinju Expressway, where traffic was blocked for 24 hours due to the debris flow in August 2005. Geographical analysis with GIS, hydrological analysis with HEC-HMS, and estimation of the amount of debris flow were carried out using field survey and soil property test data. Then, the optimum parameter combination of FLO-2D was selected through the parameter sensitivity analysis, and the behavior analysis of debris flow on expressway was applied. The comparison of the predictions with the observations shows the availability of FLO-2D for the behavior analysis of debris flow on the expressway.

Analysis of Fully Developed Multilayer Flow in Microchannel with a Rectangular Cross Section (직사각형 단면을 갖는 미세채널에서 완전 발달된 다층유동에 관한 해석)

  • Kim, Jung-Kyung;Jung, Chan-Il;Jang, Jun-Keun;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.644-654
    • /
    • 2003
  • An analytical solution for a vertically stratified viscous flow in a microchannel with a rectangular cross-section is constructed, assuming fully developed laminar flow where the interfaces between the fluid layers are flat. Although the solution is for n-layer flow, restricted results to symmetrical three-layer flow are presented to investigate the effects of the viscosity and thickness ratios of the fluid layers and the aspect ratio of the microchannel on the flow field. Relations between the flow rate and thickness ratios of the fluid layers with varying viscosity distributions are found, considering the cross -sectional velocity profiles which vary noticeably with the three parameters and differ significantly from the velocity profiles of the flow between infinite parallel plates. Interfacial instability induced by the viscosity stratification in the microchannel is discussed referring to previous studies on the instability analysis for plane multilayer flow. Exact solution derived in the present study can be used for examining a diffusion process and three -dimensional stability analysis. More works are needed to formulate the equations including the effects of interfacial' tension between immiscible liquids and surface wettability which are important in microscale transport phenomena.

Multiphase CFD Analysis of Microbubble Generator using Swirl Flow (선회유동을 이용한 마이크로버블 발생기의 다상유동 전산유체역학 해석)

  • Yun, S.I.;Kim, H.S.;Kim, J.K.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Microbubble technology has been widely applied in various industrial fields. Recently, research on many types of microbubble application technology has been conducted experimentally, but there is a limit in deriving the optimal design and operating conditions. Therefore, if the computational fluid dynamics (CFD) analysis of multiphase flow is used to supplement these experimental studies, it is expected that the time and cost required for prototype production and evaluation tests will be minimized and optimal results will be derived. However, few studies have been conducted on multiphase flow CFD analysis to interpret fluid flow in microbubble generators using swirl flow. In this study, CFD simulation of multiphase flow was performed to analyze the air-water mixing process and fluid flow characteristics in a microbubble generator with a dual-chamber structure. Based on the simulation results, it was confirmed that a negative pressure was formed on the central axis of rotation due to the strong swirling flow. And it could be seen that the air inside the suction tube was introduced into the inner chamber of the microbubble generator. In addition, as the high-speed mixed fluid collided with external water sucked by the negative pressure near the outlet, a large amount of microbubbles was ejected due to the shear force between the two flows flowing in opposite directions.

System-level Analysis of a Fan-motor Assembly for Vacuum Cleaner (진공청소기용 팬-모터 어셈블리의 시스템-레벨 분석)

  • Park, Chang-Hwan;Park, Kyung-Hyun;Chang, Kyung-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.5-14
    • /
    • 2017
  • A fan-motor assembly in a vacuum cleaner is analyzed through system-level analysis method. This system consisted of three components, a fan, motor, and the flow resistance of the motor, or of the vacuum cleaner. System-level analysis method is characterized by the combination of torque matching at a constant throttling condition between the fan and the motor and the pressure drop at a constant flow rate due to the flow resistance of the motor, or of the vacuum cleaner. The performance characteristics of the fan-motor assembly and the vacuum cleaner system could be predicted over the whole range of operation, based on the characteristics of each component. The predicted performance of the vacuum cleaner system through system-level analysis agreed well with the experimental results within 4.5% difference of pressure and 6% difference of the efficiency. The effect of flow resistance of a motor is investigated and it is found that the efficiency decrease of fan-motor assembly at the constant flow rate due to the flow resistance of a motor is determined by the flow resistance ratio(FRR), which is defined as a ratio of flow resistance of motor and the flow resistance of a constant throttling condition of a given point. The fan-motor assembly(S2 model) was modified to reduce the FRR from 9.0% to 2.4% and the experimental result shows that the efficiency of S2 model was improved by about 3% at best efficiency point.

Solidification Analysis Characteristics of Back Flow Prevention Check Valve (역류방지 체크밸브의 응고해석 특성)

  • Yoon, Jung-In;Moon, Jung-Hyun;Son, Chang-Hyo;Lee, Jung-Jin
    • Journal of Power System Engineering
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2015
  • Check valves used in vessels include shock-release function on piping system, aside from basic back flow prevention. However, proper and enough protection of system is not obtainable due to use of high-pressure and bulk fluids, resulting from enlargement of vessels. In this study, casting analysis of check valves protecting systems in flow path from water hammering or back flow is conducted, using Z-CAST program. Also, molten metal filling, flow analysis, solidification analysis and shrinkage cavity analysis are conducted. The main results are as following. Regarding filling of each risering, molten metal showed stable supply condition without being isolated. It was identified that the final solidification exists on risering, but shrinkage cavity possibly might happens at the point of isolation solidification.

A Study on the Prediction of Pressure Drop for Ship Strainer (선박용 스트레이너의 압력강하 예측에 관한 연구)

  • Son, In-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.573-579
    • /
    • 2021
  • In this study, flow analysis was performed on three types of strainers for ships with different flow rates to predict the pressure drop of the strainer due to the filter of strainer. In the case of flow analysis, the flow analysis was performed by applying the porous media method by applying the resistance value derived by Ergun's equation to the filter position. As a result of the analysis, it was found that when the dimensions of the strainer body were small, the influence of the flow rate on the pressure drop was large. In addition, the amount of pressure drop and the flow rate are almost linearly proportional, and an analysis formula that can predict the amount of pressure drop was derived. In order to predict the amount of pressure drop of the strainer when blockage exist in the strainer filter, the analysis was performed by introducing the resistance ratio to derive the prediction equation. Using this equation, it is thought that it will be possible to predict the performance of the strainer due to blockage in the future strainer design and field application.

Resin Flow Analysis of RTM Manufacturing Method for Design of Composite Fluid Storage Tank Structure (복합재료 유체 저장 탱크 구조 설계를 위한 RTM 공법 수지 유동 해석)

  • Park, Hyunbum
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.1
    • /
    • pp.69-76
    • /
    • 2019
  • In this study, resin flow analysis of resin transfer moulding (RTM) method was performed for mould design of composite structure. The target composite structure was a tank used for fluid storage. Natural c fiber composite was adopted for composite structural design of the fluid storage tank. RTM was adopted for manufacturing of the tank using natural fiber composites. Resin flow analysis was performed to find the proper RTM conditions of the tank. The resin flow analysis was performed using the commercial FEM flow simulation software. After repeated analysis while changing the location of resin inlet and outlet, the proper resin filling time and pattern were found.

Flow analysis of Ice Cone Die (아이스 콘 금형의 유동해석)

  • 이종선;김세환
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.11a
    • /
    • pp.253-257
    • /
    • 2002
  • This study is object to flow analysis of ice cone die. The finite element model was developed to compute the flow, velocity and pressure for ice cone die. For flow analysis using result from FEM Code.

The Qualitative Prediction for diffusion and transition of contaminants in the Clean Room by Numerical Flow Analysis (기류해석을 이용한 클린룸 내 오염물질의 확산경로 예측)

  • Jeong, Gi-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.382-386
    • /
    • 2007
  • In this study, the qualitative prediction and evaluation of clean room being utilized for mass production of electrronic components have been performed with the help of flow simulation. Compared to the experimental analysis based on measurements of the number of particles, concentration of contaminants and flow characteristics, the numerical analysis used in this study is much cost-effective.

  • PDF

Multiparameter Flow Cytometry: Advances in High Resolution Analysis

  • O'Donnell, Erika A.;Ernst, David N.;Hingorani, Ravi
    • IMMUNE NETWORK
    • /
    • v.13 no.2
    • /
    • pp.43-54
    • /
    • 2013
  • Over the past 40 years, flow cytometry has emerged as a leading, application-rich technology that supports high-resolution characterization of individual cells which function in complex cellular networks such as the immune system. This brief overview highlights advances in multiparameter flow cytometric technologies and reagent applications for characterization and functional analysis of cells modulating the immune network. These advances significantly support highthroughput and high-content analyses and enable an integrated understanding of the cellular and molecular interactions that underlie complex biological systems.