• Title/Summary/Keyword: floors

Search Result 862, Processing Time 0.046 seconds

Biped Walking of Hydraulic Humanoid Robot on Inclined Floors (유압식 이족 휴머노이드 로봇의 경사면 보행 연구)

  • Kim, Jung-Yup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.3
    • /
    • pp.258-266
    • /
    • 2012
  • This paper describes a biped walking algorithm for a hydraulic humanoid robot on inclined floors. To realize stable and robust biped walking, the walking algorithm was divided into five control strategies. The first is a joint position control strategy. This strategy is for tracking desired joint position trajectories with a gain switching. The second is a multi-model based ZMP (Zero Moment Point) control strategy for dynamic balance. The third is a walking pattern flow control strategy for smooth transition from step to step. The fourth is an ankle compliance control, which increases the dynamic stability at the moment of floor contact. The last is an upright pose control strategy for robust walking on an inclined floor. All strategies are based on simple pendulum models and include practical sensory feedback in order to implement the strategies on a physical robot. Finally, the performance of the control strategies are evaluated and verified through dynamic simulations of a hydraulic humanoid on level and inclined floors.

Study on the Vibration Reduction Characteristics of Floating Floors Used in Railway Vehicles (철도차량에서 사용하는 부유상구조의 진동절연특성에 관한 연구)

  • Woo, Kwan-Je;Park, Hee-Jun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.305-309
    • /
    • 2006
  • In this paper vibration reduction characteristics of floating floors used in railway vehicles are studied. Vibration reduction characteristics are compared through a series of tests for elastically-coupled floor and rigidly-coupled floor. It was found that elastically-coupled floor has larger vibration reduction amount than rigidly-coupled floor. Around the fundamental natural frequency, however, elastic floor has poor vibration reduction effect than rigid floor. Measures to reduce structure-borne noise are also discussed based on the test results. Structure-borne noise for running railway vehicles cannot be reduced by an effort to deviate resonance between natural frequency of floors and major exciting forces. Instead, reducing vibration level of top floor and using covers which have low sound radiation coefficient will be effective for reducing structure-borne noise.

  • PDF

A Study on Development and Application of Noise Estimation System for Floor Noise in Apartment Buildings (공동주택 층간소음의 소음 발생 위치 추정 시스템 개발 및 적용에 관한 연구)

  • Yun, Gee-Hyei;Kim, Sang-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.203-204
    • /
    • 2019
  • Recently, the number of conflicts and complaints related to noise between floors is increasing every year. It is essential to acquisition objective noise data in order to resolve legal disputes over floor noise. However, specialized equipment for noise acquisition is difficult for ordinary apartment dwellers to use. In addition, in order to solve the problem of inter-layer noise, it is most effective to locate and remove the noise. Therefore, this study proposes a floor noise monitoring system for the measurement of floor noise and estimation of the noise source that can be measured without a professional device.

  • PDF

Seismic Response Analysis of Computer Floors Using Base Isolation System (면진장치를 적용한 컴퓨터실 바닥의 지진응답해석)

  • 이경진
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.424-431
    • /
    • 2000
  • After the Kobe earthquake(1995) in Japan, the Izmit earthquake(1997) in Turkey and the Chi-chi earthquake(1999) in Taiwan, the small-to-medium-sized earthquakes occurred in the Koreans peninsula and this shows the fact that Korea is not located in the safety zone of earthquake. The main concept of base isolation system is to reduce the member forces by decreasing the earthquake forces transmitted to superstructure instead of the conventional techniques of strengthening the structural members. This study investigates the effect of seismic response attenuation of computer floors using base isolation systems

  • PDF

Prediction and Measurement of the Path Loss in a Building including the Staircase (계단이 포함된 건물 내부의 경로손실 예측과 측정)

  • 최태관;김성진;김채영
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.219-222
    • /
    • 1999
  • A SBR/Image ray-tracing technique using triangular ray tubes to predict the effects of walls. rooms. floors, and staircase is considered. Suggested technique is very efficient to estimate the path loss in three-dimensional buildings including the staircase. The model to predict the path loss through walls and floors in a multifloored building is presented. Measurements are made for three corridors having the staircase at 850 MHz, Measured data shows a close agreement with a simulated data.

  • PDF

Prediction of Structure-Borne Noise for Floating Floor Using SEA (SEA 기법을 이용한 부유상구조의 구조기인 소음 예측)

  • Park, Hee-Jun;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.258-264
    • /
    • 2007
  • Floating floors, which are mainly used for reducing interior noise levels of railway vehicle, are known to be superior to single structure in respect to sound transmission loss and vibration reduction performances. The stiffness of isolator is one of the important design variables in floating floors. From modal tests, modal properties of underframe, top floor and isolators are derived. They are used as input parameters for predicting structure-borne noise using AUTOSEA.

  • PDF

Study on the Effect of Vibration Reduction Characteristics of Floors on the Inside Running Noise in Railway Vehicles (전동차 바닥구조의 진동절연특성이 실내소음에 미치는 영향)

  • Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.908-912
    • /
    • 2008
  • Structure-borne noise is known to dominate internal running noise levels in open field. In this paper vibration isolation characteristics of floors are investigated to see their effect on the internal running noise. By using the analysis and test results of test specimen of small size, internal running noise level of complete train is estimated. Analysis results show that soft rubber as a vibration isolator has the most favorable effect on the inside running noise.

  • PDF

The Control of Vertical Vibration of Building Slabs using Tuned Mass Dampers (동조질량 감쇠기에 의한 건물 바닥판의 연직진동제어)

  • 이동근;김진구;안상경
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.103-114
    • /
    • 1998
  • The floors of building structures equipped with vibrating machines can be susceptible to large vibration as a result of resonance or beating. Such a vibration can be reduced efficiently by using tuned mass dampers. However, the effectiveness of the damper depends greatly on the location and the natural frequency of the damper. To determine the optimum damper location is especially important since the dynamic behavior of a building structure varies with the location of the input loading. To this end, it is intended to decide the location and natural frequency of tuned mass dampers for reducing vibration of both loaded floors and floors located nearby the loaded floors considering the location and frequency components of the loading. The Vector composition method and the super elements are used th obtain the responses in steady states, and the optimum damper location and natural frequencies were found with the given damper mass.

  • PDF

A Study on the Architectural Planning Characteristics of Medical Buildings - Focused on Cheong-ju Area (메디컬빌딩의 건축계획특성 연구 - 청주지역을 중심으로)

  • Baek, Sang Yeol;Kim, Gi Soo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2015
  • Purpose: Under a trend of hospitals that repeated expansion in line with fast increasing factors of medical demands in the past, medical buildings where clinic businesses have regularly gathered in one building have exponentially increased since separation of prescribing and dispensing in 2000. Thus, this study aims at analyzing characteristics of architectural plan of the current medical buildings, identifying strengths and weaknesses through Post Occupancy Evaluation and suggesting an architectural planning method of medical buildings to be planned in the future. Methods: Scope of study has been limited to 23 medical buildings that are registered in the building register as medical buildings out of the Class 1 neighborhood facilities build as 5 floors or more in Cheongju region since 2000 and being actually used for the usage. Study method is to define concepts of the medical buildings through literature review and advanced researches, analyze characteristics of architectural plan through drawing analysis and site survey. Results: General characteristics of architectural plans for the medical buildings in Cheongju have been analyzed. There are the most frequencies in general commercial area and semi-residential area, most of them are reinforced concrete structure and the Class 1 neighborhood facilities. Average land area is $482.68m^2$, gross floor area $3720.8m^2$, the number of underground floors level 1.16, the number of floors level 7.76, total number of floors 8.92, the building-to-land ratio 67.28%, floor area ratio 452.6%, height 31.44m, and the number of parked vehicles 24.16. Implications: This research will contribute to the establishment of the planning methods which increase the quality of Medical Buildings in Cheongju.

Effectiveness of education for control of house dust mites and cockroaches in Seoul, Korea

  • JEONG Kyoung Yong;LEE In-Yong;LEE Jongweon;REE Han-Il;HONG Chein-Soo;YONG Tai-Soon
    • Parasites, Hosts and Diseases
    • /
    • v.44 no.1 s.137
    • /
    • pp.73-79
    • /
    • 2006
  • We evaluated the efficacy of health education in reducing indoor arthropod allergens in Seoul. The mite control measures comprised the use of mite-proof mattress and pillow coverings, regular washing of potentially infested materials, maintenance of a low humidity, removal of carpets, and frequent vacuum cleaning. Cockroach control measures included trapping, application of insecticides, and protecting food. Of 201 homes enrolled in October 1999, 63 volunteers were included in a 2-year follow-up survey between April 2000 and January 2002. Before intervention, the density of mites/g of dust varied greatly; 27.1/g in children's bedding, 20/g in adult bedding, 7.2/g on the floors of children's bedrooms, 6.8/g in sofas, 5.9/g on the floors of adult's bedrooms, 3.9/g on living room floors, 3.7/g in carpets, and 1.9 mites/g on kitchen floors. The predominant mite species and house percentages infested were; Dermatophagoides farinae $93\%$, D. pteronyssinus $9\%$, and Tyrophagus putrescentiae $8\%$. Comparing 1999 and 2001 infestations, before and after 25 mo of education, mite abundance was reduced by $98\%$, from 23.7 to 0.57 mites/g of dust. In 1999, cockroaches were detected in $62\%$ homes: $36\%$ Blattella germanica and $35\%$ Periplaneta spp., including $9\%$ double infestations of B. germanica and P. americana. Following intervention, cockroach infestation rates decreased to $22\%$ of houses in 2000 and $23\%$ in 2001. We conclude that continuous and repetitive health education resulted in the effective control of domestic arthropods.