온수온돌 난방시 바닥면의 중성온도 설정에 관한 연구 (Establishment of Optimum Floor Surface Temperature Floor in Ondol Heating System)

  • 공성훈
    • 한국주거학회논문집
    • /
    • 제6권2호
    • /
    • pp.51-55
    • /
    • 1995
  • This study presents a real neutral floor surface temperature in floor panel heating system(Ondol). The Ondol heating system can keep the constant temperature. However, the actual temperature when a person sits on a floor can be different from the surface temparature of a floor it self. The contents of this study are as follows : 1) measuring the spatial distributions of thermal conditions 2) the thermal sensation vote of residents is taken in order to investigate the relation between thermal condition and human thermal sensation in sedentary condition 3) estimating the neutral floor surface temperatures by measuring floor surface temperatures.

  • PDF

현대 온돌 시스템 적용을 위한 신한옥 바닥난방의 열적특성 비교 (The comparison of thermal characteristics of new Han-ok floor heating for applying modern On-dol system)

  • 이태강;이주엽;송민정;김선우
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.61-69
    • /
    • 2013
  • The experiment on thermal characteristics of on-dol systems were carried out to apply to New Han-ok's heating system. Change of surface temperature varied with heating times, distribution of surface temperature, radiation property were surveid on four on-dol system in laboratory conditions. Followings are results. 1) "Hwang-to unit" was most favorable condition of the distribution of floor surface temperature. And the results from reaching time to thermal comfort temperature of on-dol system showed that "Hwang-to unit" was the most favorable to continuance of floor temperature. 2) There were a little difference in surface floor radiations of $30^{\circ}C$ for three wet on dol-systems. 3) It was suggested that "Hwang-to unit" is the most appropriate to floor heating system of new han-ok considering eco-friendship and continuance of floor temperature in intermittent heating condition.

경사인장형 바닥 미끄럼 시험방법의 표준화에 관한 연구 (A Study of Standardization of Floor Slip Test method using O-Y·PSM)

  • 신윤호;강용학;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.95-96
    • /
    • 2016
  • The floor slip test method using O-Y·PSM was developed based on the risk assessment and sense of slip by the users implementing actions such as changing walking direction on a floor. This test method is regulated under the Korea Industrial Standard KS M 3510, and in the Korea Industrial Standard KS F 3230, the article of KS M 3510 is cited. Yet, in the standard, the surface condition of test or slip adjustment method is merely mentioned or difficult to be found, and thus it creates confusion in floor slip test using O-Y·PSM. Therefore, this study is to provide the useful data to revise the relative standard through the standardization study including various surface conditions of sample and slip adjustment method used in floor slip test method using O-Y·PSM.

  • PDF

주거 건물의 복사냉방시스템 적용에 관한 연구 (A Study on the Application of the Radiant Floor Cooling System in Residential Building)

  • 임재한;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.

바닥재 마모에 따른 미끄럼 저항 변화 (The Variation of the Slip Resistance with Wear of Floor)

  • 김정수
    • 한국안전학회지
    • /
    • 제28권2호
    • /
    • pp.14-20
    • /
    • 2013
  • All most of floors can become less slip resistant with wear. The deterioration of slip resistance can often occur rapidly. So relatively new products can become hazardous within a short period of time. The main objective of this study was the comparison of slip resistance variations caused by traffic wear and accelerative wear. The second objective was to ascertain the effect of wear, and to find out the causes of slip resistance change. Although statistical differences were observed between results of traffic wear and accelerative wear, the trend of the variations of slip resistance caused by traffic wear and accelerative wear was very similar. The measured slip resistance of tested floor changed up to 29%(and 26.5%) after 100,000 steps(and 750 cycles). As the traffic wear and accelerative wear were progressed, the surface roughness of the tested floor became smoother, and so the floor became more slippery under the wet condition. The abraded(worn out) floor surface tended to become hydrophilic surface, while the new floor surface tended to show hydrophobic nature. This phenomenon would change the wettability of floor surface, and the wettability would affect the variation of slip resistance.

바닥 거칠기 및 미끄럼판 재질에 따른 미끄러짐 특성 연구 (Experimental Study on Slip Characteristics of Floor Surface Roughness and Slider Materials)

  • 김정수;박재석
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.65-69
    • /
    • 2010
  • This paper presented an experimental study of slip resistance characteristics of shoes and floor surface contact with special focus on the effect of surface roughness, outsole material and mechanical abrasion. The factors that affected the results of slip resistances were investigated for four kinds of rubbers and five kinds of floor samples using the VIT(English XL) tribometer. The slip resistance was observed to increase gradually with increasing roughness for five kinds of floor roughness. In the higher surface roughness (larger than $11.5{\mu}m$), the slip resistance increased more rapidly and exceeded safety criteria at $22.60{\mu}m$. The slip resistance was observed to decrease with increasing hardness of outsole, except for butylenes rubber, which seemed to show the material property. The slip resistance decreased with number of trials. In the first several times(5 or 6 trial), the slip resistance decreased more rapidly, whereafter it approached gradually constant value. The slip resistance of surfaces has generally been shown to increase with floor surface roughness and to decrease with hardness of outsole and number of trials under the wet condition.

Eletromyographic Activities of Trunk and Lower Extremity Muscles During Bridging Exercise in Whole Body Vibration and Swiss Ball Condition in Elderly Women

  • Kim, Tack-Hoon;Lee, Kang-Seong
    • 한국전문물리치료학회지
    • /
    • 제17권4호
    • /
    • pp.26-34
    • /
    • 2010
  • The purpose of this study was to compare the trunk and lower extremity muscle activity induced by six different conditions floor, intensity 0, 1, 3, 5 of whole body vibration (WBV), and Swiss ball during bridging exercise. Surface electromyography (EMG) was used to measure trunk and lower extremity muscles activity. Ten elderly women were recruited from Hong-sung Senior Citizen Welfare Center. The collected EMG data were normalized using reference contraction (during floor bridging) and expressed as a percentage of reference voluntary contraction (%RVC). To analyze the differences in EMG data, the repeated one-way analysis of variance was used. A Bonferroni's correction was used for multiple comparisons. The study showed that EMG activity of the rectus abdominis, external oblique, internal oblique, erector spinae and rectus abdominis muscles were not significantly different between six different conditions of during bridging exercise (p>.05). However, there were significantly increased EMG activity of the rectus femoris (p=.034) in the WBV intensity 0, 1, 3, and 5 conditions compared with the floor bridging condition. EMG activity of the medial gastrocnemius were significantly increased in the WBV intensity 0, 1, 3, 5 and Swiss ball conditions compared with the floor bridging condition. Future studies are required the dynamic instability condition such as one leg lifting in bridging.

바닥면의 교란에 따른 자세균형능력의 변화 (Ability to Maintain Postural Control while Standing on Perturbed Surfaces)

  • 박성하;이승원
    • 산업경영시스템학회지
    • /
    • 제31권4호
    • /
    • pp.146-152
    • /
    • 2008
  • This study was aimed to understand the effects of perturbed floor surface on human postural stability while standing. Ten subjects were asked to stand quietly on the surface with two angles of inclination ($0^{\circ}$ and $5^{\circ}$), two contamination conditions (dry and oil-contaminated), and three commercial floor materials (ceramic tile, coated wood, and vinyl tile). During each trial, a force plate with data acquisition systems was used to collect subject's center of pressure (COP) position. Measured COPs were then converted into the length of postural sway path in both subject's anterior-posterior (AP) and medio-lateral (ML) axis. Results showed that the length of sway path in ML axis was significantly affected by the angle of inclination and the type of floor material. The sway length was increased significantly at the inclination angle of $5^{\circ}$ and on the vinyl tile, respectively. The contamination condition, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that a proper treatment of floor surface and material is critical to preserving postural balance while standing.

지피상태(地被狀態)에 따른 임지(林地)의 수저유(水貯留) 특성(特性)(I) (Water Storage Characteristics of Surface Soil by the Different Forest Floor Conditions (I))

  • 이헌호;이창우
    • 한국산림과학회지
    • /
    • 제83권3호
    • /
    • pp.391-399
    • /
    • 1994
  • 임지(林地)의 지피상태별(地被狀態別) 침투능(侵透能)을 조사, 분석하여 임지의 수저유(水貯留) 특성(特性)을 밝히고, 임지의 수보전기능(水保全機能)을 계량화(計量化)하기 위해 경북(慶北) 경주군(慶州郡) 내남면(內南面) 용장리(茸長里) 소재(所在) 영남대학교(嶺南大學校) 농축산대학(農畜産大學) 부속(附屬) 연습림(演習林)에서 1993년(年) 6월(月)부터 9월(月)에 걸쳐 수행한 연구결과는 다음과 같다. 1. 지피상태에 따른 임지 표층 (0~20cm)의 침투능은 참나무림지 > $A_o$층을 제거 한 참나무림지 > $A_o$층을 제거한 소나무림지>소나무림지>임간라지(林間裸地)>초지(草地)의 크기 순위였다. 2. 강우강도(降雨强度)의 증대에 따른 지피상대별 침투능의 순향(順向)은 큰 변화가 없었고, 침투능의 절대량(絶對量)은 증가하였다. 3. 침투능과 그 영향인자들과의 상관관계(相關關係)에 있어 서 침투능은 토양경도(土壤硬度) 및 전공극량(全孔隙量)과 고도(高度)의 상관이 있었다. 4. Horton의 침투식(侵透式) 모형(模型)에 근거한 침투방정식(侵透方程式)을 지피상태별로 각각 추정(推定)할 수 있었다. 5. 전공극과 토양경도를 이용하여 나타낸 침투능으로 임지의 수저류량 추정모델을 산출(算出)할 수 있었다. 본 연구에서는 침투능이 산지지피상태에 따라 차이를 보이고 있음을 밝혔고, 침투능에 영향을 미치는 주요인자를 구명함과 동시에 추정식을 산출하였다. 이 결과로 산지의 수원함양기능의 계량화에 접근할 수 있었으며 또한 산지의 효율적인 수자원 관리를 위한 대책수립에 도움을 줄 것으로 기대된다.

  • PDF

지지 면 조건에 따른 무릎관절의 관절 위치 재현능력 비교 (Comparison of the Joint Position Sense at Knee Joint According to Surface Conditions)

  • 홍영주;원종혁;권오윤
    • 한국전문물리치료학회지
    • /
    • 제14권3호
    • /
    • pp.90-96
    • /
    • 2007
  • The purpose of this study was to compare the joint position sense at the knee joint at 3 different surface conditions by using the active knee joint angle reproduction test in the standing position. Twenty healthy volunteers (10 males and 10 females) age 20~29 years were recruited for this study. The knee joint position senses were assessed at three different surface conditions: on the floor (stable condition), TOGU (soft condition), and seat fit (unstable condition) in a closed kinetic chain. Testing orders were selected randomly. The absolute angle error was defined as the absolute difference between target angles ($30^{\circ}{\sim}45^{\circ}$ knee flexion) and subject perceived angle of the knee flexion. One way ANOVA was used to compare the absolute angle of error among 3 different conditions. The Independent t-test was used to compare the absolute angle of error between male and female. The error angles were significantly different among surface conditions ($1.3^{\circ}{\pm}1.2^{\circ}$ for the floor, $2.1^{\circ}{\pm}0.9^{\circ}$ for the TOGU, and $4.4^{\circ}{\pm}1.8^{\circ}$ for the seat fit, p<.05). There was no significant difference in error angle between male and female. In conclusion, the joint position sense of the knee joint in the closed kinetic chain decreased at unstable surface conditions. The result of this study indicates that surface conditions should be considered when assessing and training the joint position sense of the knee joint in clinical setting.

  • PDF