• 제목/요약/키워드: floor slab method

검색결과 119건 처리시간 0.024초

공동주택의 바닥충격진동 저감을 위한 유한요소법 및 다구찌법의 활용 (Application of Finite Element Method and Taguchi Method to Reduce Floor Impact Vibration in Apartment Buildings)

  • 서상호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.385-388
    • /
    • 2005
  • Finite element method and Taguchi method were used to reduce the floor impact vibration of the reinforced concrete slab in the apartment buildings. At first, experimental results show that sound peak components to influence the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab, and there is a high linear relation between floor impact vibration and sound. The tables of orthogonal arrays were used for finite element analysis with 5 factors related to slab shape parameters and its results were analyzed by statistical method. The most effective factor to reduce the floor impact vibration was the length of living/kitchen room and the floor impact vibration was predicted by 30% reduction in the acceleration peak by the optimal design values of the factors.

  • PDF

수직진동 사용성을 고려한 플랫 플레이트 슬래브의 최소두께 제안 (Minimum Thickness of Flat Plate Slab Satisfying Floor Vibration Criteria)

  • 이민정;김동현;한상환
    • 한국소음진동공학회논문집
    • /
    • 제16권6호
    • /
    • pp.574-581
    • /
    • 2006
  • Flat plate slab systems are more economical rather than reinforced concrete frame systems because flat plate slab system reduces story height. Furthermore flat plate systems are more popularly needed in construction practice due to flexibility of plan. Korean Concrete Provisions 2003 provide the minimum thickness of the slab that satisfies serviceability requirement to the static displacement. However, floor thickness in residence buildings may not satisfy the floor vibration criteria although the thickness satisfies the serviceability requirements in current design provisions. This study estimates the dynamic properties of floor vibration for existing flat plate slabs, and proposes the slab thickness satisfying the floor vibration criteria. The dynamic response analysis using finite element method and reliability analysis are carried out for this Purpose.

아파트 슬래브의 진동평가에 관한 연구 (A Study on Vibration Analysis for the Slab of Apartment Building)

  • 박강근;김용태;최영화
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.333-340
    • /
    • 2006
  • In these days the floor vibration is beginning to make its appearance of the environmental dispute in apartment building. Standard floor system are suggested for the settlement of this issue by government. The sound of floor impact sound is needed to secure comfortable quality in housing. Also, it is required an accurate analysis and a proper evaluation for floor vibration. Refine model is necessary for the floor system of housing to analyze accurately the floor vibration. But this refine model is not efficient because it is required so much running time for vibration analysis and it is difficult of modeling of standard floor slab. In this paper, new modeling methods of standard floor slab are proposed for the accurate rigidity evaluation. By using the new modeling method, the accurate vibration response can be obtained and can accurately evaluate the rigidity of standard floor system with resilient materials. Therefore the proposed modeling method is of practical use for vibration analysis of floor system of apartment building.

  • PDF

철골모멘트골조의 연쇄붕괴저항성능에 대한 바닥슬래브의 효과에 관한 해석적 연구 (Analytical Study on Effect of Floor Slab for Progressive Collapse Resistant Capacity of Steel Moment Frames)

  • 김선웅
    • 한국전산구조공학회논문집
    • /
    • 제27권1호
    • /
    • pp.27-35
    • /
    • 2014
  • 본 연구에서는 2경간 합성바닥슬래브의 기여도를 반영하여 철골모멘트골조의 연쇄붕괴저항성능의 더욱 정확한 평가를 위해 사용할 수 있는 개선된 에너지기반 비선형정적 해석법을 제시하고자 한다. 이를 위해, 우선 재료적/기하학적 비선형 유한요소해석을 수행하여 2경간 합성바닥슬래브의 거동을 살펴보았다. 2경간 합성바닥슬래브의 변형형상을 이상화하여 에너지기반 해석을 위한 근사모델을 개발하였다. 제안모델은 기둥제거 시나리오하에서 2경간 합성바닥슬래브의 일방향 축인장력 및 변형에너지응답을 모델링하는데 쉽게 이용할 수 있음을 보여주고 있다.

슬래브의 동특성과 중량충격음의 상관관계에 관한 연구 (Research about correlation of slab vibration mode and heavy-weight floor impact sound)

  • 정진연;이상우;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.839-843
    • /
    • 2008
  • Receiving room's floor impact sound level is been influenced to various factor of slab thickness, room size, structure etc. This study examined the noise of upper part slab and room mode in receiving room to be importance factor that influence in receiving room level among this factors. According to this study, vibration mode in slab and room mode are concentrated on frequency that is high level relatively. This causes bad effect in floor impact sound level. Therefore, method to reduce floor impact sound level is to change vibration mode using slab upper part's resilient material or reduce room mode in receiving room.

  • PDF

2방향 중공슬래브의 효율적인 해석 (Efficient Analysis of Biaxial Hollow Slab)

  • 박현재;김현수;박용구;황현식;이기장;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.362-367
    • /
    • 2008
  • Recently, the use of biaxial hollow slab is increased to reduce noise and vibration of the floor slab. Therefore, an efficient method for the vibration analysis of biaxial hollow slab is required to describe dynamic behavior of biaxial hollow slab. A finite element analysis is one of the method to analyze the biaxial hollow slab. It is necessary to use a refined finite element model for an accurate analysis of a floor slab with an effects of the hollow shape. But it would take a significant amount of computational time and memory if the entire building structure were subdivided into a finer mesh. Thus the proposed method uses equivalent plate model in this study. Dynamic analyses of an example structure subjected to walking loads were performed to verify the efficiency and accuracy of the proposed method.

  • PDF

아파트 거실 바닥판에 대한 진동해석 (Vibration Analysis for the Living Room Slab of Apartment)

  • 김용태;박강근
    • 한국공간구조학회논문집
    • /
    • 제6권3호
    • /
    • pp.93-101
    • /
    • 2006
  • 아파트의 온돌 바닥판은 콘크리트 바닥판위에 경량기포 모르타르, 완충재, 마감 모르터가 복층으로 시공되어 콘크리트 바닥판 상부의 시공방법 및 재료에 의한 구조적 거동에 대한 영향이 다르게 나타난다. 따라서 보다 합리적인 아파트의 콘크리트 적층 바닥판의 진동평가를 위해서는 시공방법 및 재료를 고려한 새로운 개선된 진동핵석 모델이 요구된다. 본 논문에서는 실제아파트의 적층으로 시공된 콘크리트 바닥판에 대한 보다 합리적인 진동해석 방법을 제안하고자 한다.

  • PDF

Limit states of RC structures with first floor irregularities

  • Favvata, Maria J.;Naoum, Maria C.;Karayannis, Chris G.
    • Structural Engineering and Mechanics
    • /
    • 제47권6호
    • /
    • pp.791-818
    • /
    • 2013
  • The seismic performance of reinforced concrete (RC) frame structures with irregularities leading to soft first floor is studied using capacity assessment procedures. The soft first story effect is investigated for the cases: (i) slab-column connections without beams at the first floor, (ii) tall first story height and (iii) pilotis type building (open ground story). The effects of the first floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40) and on the Coefficient Method (FEMA 356) is also examined. Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behaviour are presented. From the results it can be deduced that the global capacity of the structures is decreased due to the considered first floor morphology irregularities in comparison to the capacities of the regular structure. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities while the open ground floor structure (pilotis type) led to even higher values of interstory drift demands at the first story. In the cases of tall first story and slab-column connections without beams soft-story mechanisms have also been observed at the first floor. Rotational criteria (EC8-part3) showed that the structure with slab-column connections without beams exhibited the most critical response.

장선슬래브를 갖는 소형평형 벽식구조 아파트 바닥구조의 중량충격음 특성 (Heavy-weight Impact Sound Characteristics of Floor Structure of a Small-Sized Wall-Slab Apartment Building having Joist Slab)

  • 천영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.8-15
    • /
    • 2020
  • 이 논문에서는 최근 사회적인 이슈로 대두된 바닥충격음 중 특히 중량충격음을 저감시키기 위한 방법의 일환으로, 바닥슬래브의 두께를 증가시키는 기존의 방식과는 달리 평판형 슬래브에 장선을 설치하여 바닥슬래브의 강성을 증가시킴으로써 고유진동수의 이동을 통한 중량충격음의 저감 효과를 기대할 수 있는 장선바닥슬래브를 제안하고, 장선의 춤과 간격에 따른 중량충격음 특성을 해석적으로 분석하였다. 해석결과, 장선슬래브의 슬래브 두께가 증가할수록 음압레벨이 감소하는 경향을 나타내었으나 일정 두께 이상에서는 큰 차이를 보이지 않아 바닥두께 증가로 인한 중량충격음 차단 기대효과에는 임계치가 있을 것으로 판단된다. 또한 장선 춤의 증가와 간격 감소에 따른 바닥강성의 증가는 일관된 중량충격음 차단성능의 증가로 이어지지 않아 최적의 중량충격음 차단성능을 기대하기 위해서는 주택의 유형별로 각기 다른 장선 춤과 간격이 적용되어야 할 것으로 판단되며, 100mm 정도 장선 춤의 증가나 간격 감소로 약 1dB~2dB정도의 중량충격음 감소효과를 얻을 수 있을 것으로 기대된다.

Seismic behavior of RC building by considering a model for shear wall-floor slab connections

  • Soleimani-Abiat, Mehdi;Banan, Mohammad-Reza
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.381-397
    • /
    • 2015
  • Connections are the most important regions in a structural system especially for buildings in seismic zones. In R.C. structures due to large dimensions of members and lack of cognition of the stress distribution in a connection, reaching a comprehensive understanding of the connection behaviors becomes more complicated. The shear wall-to-floor slab connections in lateral load resisting systems have a potential weakness in transferring loads from slabs to shear walls which might change the path of load transformation to shear walls. This paper tries to investigate the effects of seismic load combinations on the behavior of slabs at their connection zones with the shear walls. These connection zones naturally are the most critical regions of the slabs in RC buildings. The investigation carried on in a simulated environment by considering three different structures with different shear wall layout. The final results of our study reveal that layout of shear walls in a building significantly affects the magnification of forces developed at the shear wall-floor slab connections.