• 제목/요약/키워드: floor finishing material

검색결과 71건 처리시간 0.027초

바닥충격음 측정 및 차음 평가의 방향 (Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance)

  • 정정호;정영;서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

다중이용업소 실내마감재료 사용기준에 관한 연구 (A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses)

  • 김용성;조성오
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

콘크리트 바닥 시험체의 크기가 SL재의 균열에 미치는 영향 - SL재의 하자 발생에 영향을 미치는 콘크리트 표층부의 품질 평가방법(I) - (Evaluation on Crack in Self-leveling Material and Investigation about Influence of Specimen Size - Evaluation Method about Surface Layer Quality of Concrete Floor Groundwork Corresponding to Defect in Self-leveling Material (Part I) -)

  • 김두호;최수경
    • 한국건축시공학회지
    • /
    • 제7권2호통권24호
    • /
    • pp.99-106
    • /
    • 2007
  • The purpose of this study presents in Relations between cracks in self-leveling material and quality of floor groundwork surface are experimentally examined. As the first stage, the experiment to observe cracks in self-leveling material constructed on floor groundwork made from various kinds of concrete was carried. As a result, following basic findings were obtained. First, observation of cracks should be continued until an increase in width of cracks stop, without constructing any finishing material. Second, degree of cracks may be indicated quantitatively by the product of length and width. Finally, Cracks and separation is not be influenced by specimen size. Based on these findings, the method of predicting cracks by evaluating surface layer quality of floor groundwork will be established.

최근 서울시 중형 OFFICE 건물의 실내재료의 사용경향에 관한 연구 (A Study on the Using Trends of Interior Materials in Current Medium Size Office Building in Seoul)

  • 김은중
    • 한국실내디자인학회논문집
    • /
    • 제23호
    • /
    • pp.19-25
    • /
    • 2000
  • This study aims by analysing the interior design elements trends of current medium size office buildings in Seoul. The analysing objects are ceiling, floor, wall, and illumination plan of current office buildings. Analysing tools are finishing material and color of each part. Analysing areas are lobby area, deskwork area, conference area, welfare area, public area(rest room, corridor, stair). The interior design elements of lobby shows a lots of different features then the other areas in ceiling, floor, and wall design. Such difference appears at finishing material especially, and the coloring is more splendorous then the other areas. Desk work area and conference area have similar characteristics in finishing materiors and colors, and they usually follow the needs of function. Walfare area shows more splendorous feature then deskwork and conference area, and designed by various materials and colors. Public area also shows very active design concept then past times.

  • PDF

EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발 (The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form)

  • 박철용;김상훈;장동운;장철호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석 (An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis)

  • 문대호;박홍근;황재승;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제24권5호
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

교회공간 예배실의 위치적 기능에 따른 마감재 적용 연구 (A Study on the Application of Finishing Materials According to the Locational Function of the Chapel in Church Space)

  • 여미;이창노
    • 한국실내디자인학회논문집
    • /
    • 제24권1호
    • /
    • pp.178-188
    • /
    • 2015
  • This study has the main objective of being of help as a reference data for the application of the finishing materials when designing the interior of the chapel of the church space through analysis of the finishing materials against the chapels of church space which has complex function. As precedent studies for this, the composition of the function and concept of the church space was surveyed and the complex function of the church space was surveyed. The theoretical surveyed was performed according to the casual composition, behavior of the community and role and location of the duties of the church members. The case objects were 10 chapels constructed by 5 professional interior design companies. The content of the analysis was the finishing materials in the chapels and their application characteristics. The detailed considerations to be referred to when designing the interior of the chapels of church space in the future were proposed. The analysis result of the application of the finishing materials according to the locational function of the chapels of church space can be explained as follows. First, the platform area was the characteristic of applying finishing materials which induce visual immersion. As for the floor materials in the platform, in order to minimize the floor sound and vibration phenomenon occurring during movements, noise insulation and dust protection rubber sheet was place and on top of it the floor or the carpet was placed. Second, the Choir area had the difficult problem of having to consider the appropriate sound absorption occurring due to the proliferation of sound and performance of classical instruments at the same time. However, in the case, this problem was solved through the sculptures of convex shape. Third, since the scheelite is a space where many people move around, the finishing material which absorbs sound was mainly used. Fourth, the entrance area was composed of thick wall materials compared to other walls, and the sound absorption character was most significantly considered when applying the finishing material. Fifth, the broadcasting room was composed either in independent type or an open type and performed its function and the main finishing materials was transparent glass which was highest use frequency.

수반응 우레탄과 바닥용 경질 폴리우레탄을 이용한 바닥마감재의 성능향상에 관한 실험적 연구 (A study on the improvement for performance of floor finishing materials using poly urethane with water reacting urethane)

  • 박진상;강효진;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.43-46
    • /
    • 2006
  • In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.

  • PDF

시선추적을 이용한 카페 공간 마감재 차이의 시각주의력 특성 (Characteristics of Visual Attention for the Different Type of Material Finishing in Cafe Space Using by Eye-tracking)

  • 최진경;김주연
    • 한국실내디자인학회논문집
    • /
    • 제27권2호
    • /
    • pp.3-11
    • /
    • 2018
  • This study aims to investigate whether there is intensionally changing eye - gaze on the cafe space images with floor finishing materials. In the Yarbus' experiment, he argued that changing information that an observer is asked to obtain from an image changes pattern of eye movements. Based on the scan path evidence, this research have questions as (1) the difference of visual attention on finishing floor material stimulus, (2) visual attention of initial activity time and type of movement paths on AOIs, and (3) visual relation floor area with another AOIs. Eye movements were recorded with the SMI REDn Scientific, which sampled eye position at 30Hz and lasted 2 minutes(120s). Although viewing was binocular, only the right eye was tracked. Of the 66 observers(mean age 22 years, standard deviation: ${\pm}1.82$) who participated in the experiment done by the four point calibration and validation procedures at the beginning tasks. Analyzing qualitative data from the number of fixation and duration on AOIs divided into four parts (AOI I-Floor, AOI II-Wall, AOI III-Ceiling, and AOI IV-Counter) in the stimulus. The results from this experiment analyzed as follows. First, it was significant in the difference of the average number of AOIs fixation times observed for the spatial image using the wood tile flooring material and the polishing tile. The wood tile flooring of stimulus had higher fixation number on AOI-II, AOI-III, and AOI-IV than the polishing tile. On seeing AOI-I was higher attention in the polishing tile stimulus. Second, the observers examined AOI-II intensively in both stimuli. However, the visual intensity was also followed by on the AOI-IV and AOI-I in the wood tile flooring stimulus, and on AOI-I, AO-IV in the polishing tile. Third, visual attention data on each AOIs have divided into the time range of "5 sec" for both images. In the wood tile stimulus, the horizontal movement path followed by AOI-II, AOI-IV, and AOI-II. In the polished tile stimulus, the movement path followed by moving vertically to AOI-II, AOI-I, and AOI-II. This study approached meaningfully and found out the characteristics of visual attention, according to the different intentions of visual attention, the relationship pathways of visual mechanism appeared and also activated by eye-tracking experiments.

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF