평판 부착형 제진시스템을 이용한 구조기인 소음 저감에 관한 연구 (Noise control of a slab using the laminated composite damping system)

  • 황재승;김광용;홍건호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.403-407
    • /
    • 2009
  • It is reported that the heavy weight floor impact noise of a slab system is very sensitive to the location of microphone and impact load. In addition, it is known that the aspect raio, thickness and boundary condition of a slab also have great effect on the noise induced by impact load. However, the effect has been mainly evaluated by experimental test and numerical analysis is nearly performed to verify the effect quantitatively. In this study, the effect of the aspect ratio, thickness and boundary condition on the heavy weight floor impact noise is examined through numerical analysis for simple rectangular slab system. The results show that the thickness and boundary condition have a strong correlation with the noise of the slab, on the contrary, the aspect ratio has little relation with the noise.

  • PDF

현대 온돌 시스템 적용을 위한 신한옥 바닥난방의 열적특성 비교 (The comparison of thermal characteristics of new Han-ok floor heating for applying modern On-dol system)

  • 이태강;이주엽;송민정;김선우
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.61-69
    • /
    • 2013
  • The experiment on thermal characteristics of on-dol systems were carried out to apply to New Han-ok's heating system. Change of surface temperature varied with heating times, distribution of surface temperature, radiation property were surveid on four on-dol system in laboratory conditions. Followings are results. 1) "Hwang-to unit" was most favorable condition of the distribution of floor surface temperature. And the results from reaching time to thermal comfort temperature of on-dol system showed that "Hwang-to unit" was the most favorable to continuance of floor temperature. 2) There were a little difference in surface floor radiations of $30^{\circ}C$ for three wet on dol-systems. 3) It was suggested that "Hwang-to unit" is the most appropriate to floor heating system of new han-ok considering eco-friendship and continuance of floor temperature in intermittent heating condition.

인체의 자세가 체온조절에 미치는 영향 (The effect of posture on the human thermoregulatory response)

  • 심현섭;최정화
    • 한국의류학회지
    • /
    • 제17권3호
    • /
    • pp.415-427
    • /
    • 1993
  • The purpose of this study was to evaluate the thermoregulatory responses to postures under different environmental conditions and to obtain the basal information for standard clothing weight, indoor climates, and working condition. Two adult female (22.5yrs, 46kg) were participated in this study. The experimental conditions were divided into three groups ; 1) comfort($27{\pm}1^{\circ}C$, $60{\pm}10%$), 2) hot($34{\pm}1^{\circ}C$, $60{\pm}10%$), and 3) cold($21{\pm}1^{\circ}C$, $50{\pm}10%$) condition. The postures performed were as follows; standing, sitting on the chair, sitting on the floor, and supine on the floor. At each condition, subjective sensations, 12 points skin temperature, rectal temperature, total and local sweat rate, pulse rates, blood pressure, skin blood flow rate were measured. The results were as follows : 1. Rectal temperature was high significant among groups in order of supine, sitting on the floor, sitting on the chair, standing posture(p<0.01). 2. Skin temperature was high in part of contact with the surface of the floor or wall and the effect of posture was greater in peripheral temperature than torso temperature. Sitting on the chair and sitting on the floor posture showed higher peripheral temperature than standing and supine posture. And peripheral temperature was lower in supine posture than any other postures. 3. Total and local sweat rate were decreased in order of standing, sitting on the chair, sitting on the floor, supine posture. 4. Pulse rate and disastolic blood pressure were higher in standing posture than supine posture, and there was significant difference between two postures(p<0.001). 5. Blood flow rate of thigh was high in sitting on the chair and sitting on the floor posture and low in standing posture. Blood flow rate of leg was low in standing posture significantly(p<0.01). 6. In comfort and hot condition, temperature sensation and comfort sensation were higher in standing posture and lower in supine posture than any other postures. In cold condition, temperature sensation was lower and comfort sensation was higher in standing and supine posture than any other postures. And supine posture was appeared positive in hot condition and negative in cold condition. From this study, we confirmed the effects of posture on human thermoregulatory responses. Results indicate that even under same conditions and clothing weight, the insulation of clothing will be different to postures.

  • PDF

Eletromyographic Activities of Trunk and Lower Extremity Muscles During Bridging Exercise in Whole Body Vibration and Swiss Ball Condition in Elderly Women

  • Kim, Tack-Hoon;Lee, Kang-Seong
    • 한국전문물리치료학회지
    • /
    • 제17권4호
    • /
    • pp.26-34
    • /
    • 2010
  • The purpose of this study was to compare the trunk and lower extremity muscle activity induced by six different conditions floor, intensity 0, 1, 3, 5 of whole body vibration (WBV), and Swiss ball during bridging exercise. Surface electromyography (EMG) was used to measure trunk and lower extremity muscles activity. Ten elderly women were recruited from Hong-sung Senior Citizen Welfare Center. The collected EMG data were normalized using reference contraction (during floor bridging) and expressed as a percentage of reference voluntary contraction (%RVC). To analyze the differences in EMG data, the repeated one-way analysis of variance was used. A Bonferroni's correction was used for multiple comparisons. The study showed that EMG activity of the rectus abdominis, external oblique, internal oblique, erector spinae and rectus abdominis muscles were not significantly different between six different conditions of during bridging exercise (p>.05). However, there were significantly increased EMG activity of the rectus femoris (p=.034) in the WBV intensity 0, 1, 3, and 5 conditions compared with the floor bridging condition. EMG activity of the medial gastrocnemius were significantly increased in the WBV intensity 0, 1, 3, 5 and Swiss ball conditions compared with the floor bridging condition. Future studies are required the dynamic instability condition such as one leg lifting in bridging.

전주한옥마을 주거건축 평면의 특징에 관한 연구 (A Study on the Characteristics of the Housing Floor Plan in Jeonju Hanok Village)

  • 남해경
    • 한국주거학회논문집
    • /
    • 제21권4호
    • /
    • pp.139-148
    • /
    • 2010
  • This study aims to classify and find the characteristics of the housing floor plan by their spatial organization, the condition of use, the process of changes in Jeonju Hanok Village. To carry out this study, first the 534 in 779 housings in this village are investigated, and finally 55 of them are investigated and analyzed. They are surveyed and investigated from November in 2008 to January in 2010. The followings are as conclusions; The prototype of housing floor plan in this village is consisted of the main room in the middle part with the toimaru (wooden veranda), kitchen and meoribang (the room that is located back or the side of the main room) and kennen-bang (the room that is located the side of main room) in it's house. They are generated and changed on the basis of this type. The floor plans of the housings in Jeonju Hanok Villages are classified and characterized as the type of original floor plan house (original type), that of semi foreign house with the Korean style by the Japanese style or modern style, that of the house for rent a room or two rooms or one family, that of the house which mixed with commercial function and that of etc. They are generated by the social and economic condition of that period. And they will be studied with the life style of residents.

강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구 (A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe)

  • 김창희;김종수;우재호;공상운
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

수직진동에 대한 사용성을 고려한 경계조건에 따른 2방향 슬래브 최소두께 제안 (Proposing the Thickness of 2-Way Slab Satisfying Floor Vibration Criteria for Several Boundary Condition)

  • 김동현;이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.199-202
    • /
    • 2005
  • KCI 2003 provides minimum thickness of slab that satisfies serviceability to static displacement. Previous study (Han, et al. 2003) showed the several slabs that designed according to minimum thickness criteria had floor vibration problem. In this study, evaluate the floor vibration serviceability of KCI 2003 minimum thickness requirements for 2-way flat plate and propose the minimum thicknesses of 2-way slabs that satisfy floor vibration criteria according to several boundary condition. For this purpose, one degree of freedom model is used and Monte Carlo simulation is performed.

  • PDF

아파트 평면형상에 따른 바닥판의 동특성 해석 (Dynamic analysis of the floor structures with different floor plans in apartments)

  • 유승엽;이평직;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1459-1462
    • /
    • 2007
  • In this study, vibration characteristics of concrete slab were investigated through FEM analysis. Four different floor plans with the floor area of $100{\sim}130m^2$ were chosen to be analyzed. Boundary conditions of two dimensional finite element models were determined based on the modal test results. Results showed that mode shapes were formed somewhat different according to the floor plan and the contribution of 1st mode on the floor vibration is generally the highest. Through the transient analysis, it was also found that floor plan, expecially connection of the living room with the kitchen, affected the vibration acceleration levels.

  • PDF

A simplified method for determining the acceleration amplitudes of long-span floor system under walking/running loads

  • Cao, Liang;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • 제75권3호
    • /
    • pp.377-387
    • /
    • 2020
  • Modern long-span floor system typically possesses low damping and low natural frequency, presenting a potential vibration sensitivity problem induced by human activities. Field test and numerical analysis methods are available to study this kind of problems, but would be inconvenient for design engineers. This paper proposes a simplified method to determine the acceleration amplitudes of long-span floor system subjected to walking or running load, which can be carried out manually. To theoretically analyze the acceleration response, the floor system is simplified as an anisotropic rectangular plate and the mode decomposition method is used. To facilitate the calculation of acceleration amplitude aP, a coefficient αwmn or αRmn is introduced, with the former depending on the geometry and support condition of floor system and the latter on the contact duration tR and natural frequency. The proposed simplified method is easy for practical use and gives safe structural designs.

노인요양시설의 평면 특성에 관한 고찰 (A Study on the Characteristics of the Floor Plan of Skilled Nursing Facilities for the Elderly in Rural Areas)

  • 양금석
    • 한국농촌건축학회논문집
    • /
    • 제18권1호
    • /
    • pp.39-46
    • /
    • 2016
  • The purpose of this study is to clarify the actual conditions of the floor area of skilled nursing facilities in rural area. The thorough investigation and observation works were made from the viewpoints of floor area of the skilled nursing facilities. This article discusses about the basic condition and the floor area for daily living activities of the elderly in 3 skilled nursing facilities in west gyeongnam province. As the result, There is a wide gap between floor area ratio of skilled nursing facilities. The characteristics of the private establishment skilled nursing facilities in the west gyeongnam province were figured out through the analysis of spatial composition in skilled nursing facilities for the elderly. The skilled nursing facilities in west gyeongnam mainly focus on the living environment orientated toward the bedroom. The difficulty is to encourage the communication between the skilled nursing facility patients because the facilities are composed of small semi-public zone.