• 제목/요약/키워드: floor accelerations

검색결과 66건 처리시간 0.02초

Evaluating Methods of Vibration Exposure and Ride Comfort in Car

  • Park, Se Jin;Subramaniyam, Murali
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.381-387
    • /
    • 2013
  • Objective: This paper studies the method of measuring whole-body vibration in the car and terms associated. Background: Human exposure to vibration can be broadly classified as localized and whole-body vibration. The whole-body vibration affects the entire body of the exposed person. It is mainly transmitted through the seat surfaces, backrests, and through the floor to an individual sitting in the vehicle. It can affect the comfort, performance, and health of individuals. Method: Human responses to whole-body vibration can be evaluated by two main standards such as ISO 2631 and BS 6841. The vibration is measured at 8 axes - three translations at feet, 3 translations of hip and two translations of back proposed by Griffin. B&K's sensors used in this study are the 3-axes translational acceleration sensor to measure the translational accelerations at the hip, back and foot. Results: The parameters associated with the whole-body vibration in the car are frequency weightings, frequency weighted root-mean-square, vibration dose values, maximum transient vibration value, seat effective amplitude transmissibility, ride values and ride comfort. Conclusion: Studied the evaluating methods of vibration exposure and ride comfort. Application: Evaluation of whole-body vibration in the car.

COMPARISON OF RIDE COMFORTS VIA EXPERIMENT AND COMPUTER SIMULATION

  • Yoo, W.S.;Park, S.J.;Park, D.W.;Kim, M.S.;Lim, O.K.;Jeong, W.B.
    • International Journal of Automotive Technology
    • /
    • 제7권3호
    • /
    • pp.309-314
    • /
    • 2006
  • In this paper, the ride comfort from a computer simulation was compared to the experimental result. For measuring ride comfort of a passenger car, acceleration data was obtained from the floor and seat during highway running with different speeds. The measured acceleration components were multiplied by the proper weighting functions, and then summed together to calculate overall ride values. Testing several passenger cars, the ride comforts were compared. In order to investigate the effect of vibration signals on the steering wheel, an apparatus to measure the vibrations and weighting functions on the steering wheel were designed. The effect of the steering accelerations on the ride comfort were investigated and added for the overall ride comfort. For the computer simulations, Korean dummy models were developed based on the Hybrid III dummy models. For the Korean dummy scaling, the national anthropometric survey of Korean people was used. In order to compare and check the validity of the developed Korean dummy models, dynamic responses were compared to those of Hybrid III dummy models. The computer simulation using the MADYMO software was also compared to the experimental results.

모드 특성을 이용한 건축 구조물의 강성 및 감쇠 행렬식별 (Identification of Stiffness and Damping Matrix of Building Structures using Modal Characteristics)

  • 강경수
    • 한국지진공학회논문집
    • /
    • 제8권2호
    • /
    • pp.45-53
    • /
    • 2004
  • 본 연구에서는 자유진동, 조화하중, 그리고 백색잡음실험을 통해 얻어지는 진동수, 감쇠비, 모드 벡타와 같은 구조물의 모드정보를 이용하여 강성행렬과 감쇠행렬을 구성하였다. 입력신호로는 지진하중을 모사 하는 바닥판 가속도를 이용하였고, 출력신호는 각층 절대가속도를 사용하였다. 각각의 실험에서 얻어지는 구조물 모드정보의 제한조건과 그에 따른 시스템 식별 모델들의 특성을 비교하였다. 본 연구의 결과는 진동대 실험을 위한 기초적인 동적 실험 및 분석에 이용될 수 있을 것으로 판단된다.

Probabilistic behavior of semi-active isolated buildings under pulse-like earthquakes

  • Oncu-Davas, Seda;Alhan, Cenk
    • Smart Structures and Systems
    • /
    • 제23권3호
    • /
    • pp.227-242
    • /
    • 2019
  • Seismic isolation systems employ structural control that protect both buildings and vibration-sensitive contents from destructive effects of earthquakes. Structural control is divided into three main groups: passive, active, and semi-active. Among them, semi-active isolation systems, which can reduce floor displacements and accelerations concurrently, has gained importance in recent years since they don't require large power or pose stability problems like active ones. However, their seismic performance may vary depending on the variations that may be observed in the mechanical properties of semi-active devices and/or seismic isolators. Uncertainties relating to isolators can arise from variations in geometry, boundary conditions, material behavior, or temperature, or aging whereas those relating to semi-active control devices can be due to thermal changes, inefficiencies in calibrations, manufacturing errors, etc. For a more realistic evaluation of the seismic behavior of semi-active isolated buildings, such uncertainties must be taken into account. Here, the probabilistic behavior of semi-active isolated buildings under historical pulse-like near-fault earthquakes is evaluated in terms of their performance in preserving structural integrity and protecting vibration-sensitive contents considering aforementioned uncertainties via Monte-Carlo simulations of 3-story and 9-story semi-active isolated benchmark buildings. The results are presented in the form of fragility curves and probability of failure profiles.

Experimental validation of the seismic analysis methodology for free-standing spent fuel racks

  • Merino, Alberto Gonzalez;Pena, Luis Costas de la;Gonzalez, Arturo
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.884-893
    • /
    • 2019
  • Spent fuel racks are steel structures used in the storage of the spent fuel removed from the nuclear power reactor. Rack units are submerged in the depths of the spent fuel pool to keep the fuel cool. Their free-standing design isolates their bases from the pool floor reducing structural stresses in case of seismic event. However, these singular features complicate their seismic analysis which involves a transient dynamic response with geometrical nonlinearities and fluid-structure interactions. An accurate estimation of the response is essential to achieve a safe pool layout and a reliable structural design. An analysis methodology based on the hydrodynamic mass concept and implicit integration algorithms was developed ad-hoc, but some dispersion of results still remains. In order to validate the analysis methodology, vibration tests are carried out on a reduced scale mock-up of a 2-rack system. The two rack mockups are submerged in free-standing conditions inside a rigid pool tank loaded with fake fuel assemblies and subjected to accelerations on a unidirectional shaking table. This article compares the experimental data with the numerical outputs of a finite element model built in ANSYS Mechanical. The in-phase motion of both units is highlighted and the water coupling effect is detailed. Results show a good agreement validating the methodology.

Reduced-mass Adaptive TMD for Tall Buildings Damping

  • Weber, Felix;Huber, Peter;Spensberger, Simon;Distl, Johann;Braun, Christian
    • 국제초고층학회논문집
    • /
    • 제8권2호
    • /
    • pp.117-123
    • /
    • 2019
  • Tall buildings are prone to wind-induced vibrations due to their slenderness whereby peak structural accelerations may be higher than the recommended maximum value. The common countermeasure is the installation of a tuned mass damper (TMD) near the highest occupied floor. Due to the extremely large modal mass of tall buildings and because of the narrow to broad band type of wind excitation the TMD mass may become inacceptable large - in extreme cases up to 2000 metric tons. It is therefore a need to develop more efficient TMD concepts which provide the same damping to the building but with reduced mass. The adaptive TMD concept described in this paper represents a solution to this problem. Frequency and damping of the adaptive TMD are controlled in real-time by semi-active oil dampers according to the actual structural acceleration. The resulting enhanced TMD efficiency allows reducing its mass by up to 20% compared to the classical passive TMD. The adaptive TMD system is fully fail-safe thanks to a smart valve system of the semi-active oil dampers. In contrast to active TMD solutions the adaptive TMD is unconditionally stable and its power consumption on the order of 1 kW is negligible small as controllable oil dampers are semi-active devices. The adaptive TMD with reduced mass, stable behavior and lowest power consumption is therefore a preferable and cost saving damping tool for tall buildings.

Optimal earthquake intensity measures for probabilistic seismic demand models of ARP1400 reactor containment building

  • Nguyen, Duy-Duan;Thusa, Bidhek;Azad, Md Samdani;Tran, Viet-Linh;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4179-4188
    • /
    • 2021
  • This study identifies efficient earthquake intensity measures (IMs) for seismic performances and fragility evaluations of the reactor containment building (RCB) in the advanced power reactor 1400 (APR1400) nuclear power plant (NPP). The computational model of RCB is constructed using the beam-truss model (BTM) for nonlinear analyses. A total of 90 ground motion records and 20 different IMs are employed for numerical analyses. A series of nonlinear time-history analyses are performed to monitor maximum floor displacements and accelerations of RCB. Then, probabilistic seismic demand models of RCB are developed for each IM. Statistical parameters including coefficient of determination (R2), dispersion (i.e. standard deviation), practicality, and proficiency are calculated to recognize strongly correlated IMs with the seismic performance of the NPP structure. The numerical results show that the optimal IMs are spectral acceleration, spectral velocity, spectral displacement at the fundamental period, acceleration spectrum intensity, effective peak acceleration, peak ground acceleration, A95, and sustained maximum acceleration. Moreover, weakly related IMs to the seismic performance of RCB are peak ground displacement, root-mean-square of displacement, specific energy density, root-mean-square of velocity, peak ground velocity, Housner intensity, velocity spectrum intensity, and sustained maximum velocity. Finally, a set of fragility curves of RCB are developed for optimal IMs.

Effectiveness of seismic isolation in a reinforced concrete structure with soft story

  • Hakan Ozturk;Esengul Cavdar;Gokhan Ozdemir
    • Structural Engineering and Mechanics
    • /
    • 제87권5호
    • /
    • pp.405-418
    • /
    • 2023
  • This study focused on the effectiveness of seismic isolation technique in case of a reinforced concrete structure with soft story defined as the stiffness irregularity between adjacent stories. In this context, a seismically isolated 3-story reinforced concrete structure was analyzed by gradually increasing the first story height (3.0, 4.5, and 6.0 m). The seismic isolation system of the structure is assumed to be composed of lead rubber bearings (LRB). In the analyses, isolators were modeled by both deteriorating (temperature-dependent analyses) and non-deteriorating (bounding analyses) hysteretic representations. The deterioration in strength of isolator is due to temperature rise in the lead core during cyclic motion. The ground motion pairs used in bi-directional nonlinear dynamic analyses were selected and scaled according to codified procedures. In the analyses, different isolation periods (Tiso) and characteristic strength to weight ratios (Q/W) were considered in order to determine the sensitivity of structural response to the isolator properties. Response quantities under consideration are floor accelerations, and interstory drift ratios. Analyses results are compared for both hysteretic representations of LRBs. Results are also used to assess the significance of the ratio between the horizontal stiffnesses of soft story and isolation system. It is revealed that seismic isolation is a viable method to reduce structural damage in structures with soft story.

급경사 해저면에 대한 파랑의 반응특성 (The Characteristics of Waves on the Steep Sloping Sea Bottom)

  • 염원기;이중우
    • 한국항만학회지
    • /
    • 제6권2호
    • /
    • pp.43-64
    • /
    • 1992
  • This study discusses the interacting with deep water waves approaching from deep water based on the linear wave theory and steep sloping sea bottom floor by the numerical procedure. The results of particular interest are particle velocity and acceleration in x, y, z direction wave height amplification factor reflection coefficient and dimensionless pressure distribution on the steep sloping bottom with respect to the various incident wave angle. The wave loads relative to various bottom slopes, incident wave angles and wave periods on submerged breakwater and pipe are represented in comparison with mild sloping bottom the wave load parameters on the steep sloping bottom seemed to be influenced by variation of incident wave angle. In general the particle velocities and accelerations in x, y, z directions on the steep sloping bottom represented larger value or about two than those on the mild sloping bottom according to incident wave angle. However, the wave height amplification factors did not show distinct difference, but the slight variation with respect to the various incident angle showed on mild sloping bottom. The reflection coefficient increased with respect to increase of the incident angle on the steep sloping bottom the results also indicate that the very steep sloping beach produces a rather substantial amount of reflection as we expected. No significant variation of wave pressure was shown on the steep sloping bottom but it represented a certain amount of variation on the mild sloping bottom according to the various incident wave angle. The analysis at the OTEC site also showed similar results.

  • PDF

원전 전기캐비넷의 지진취약도 재평가를 위한 진동대 실험 (A Shaking Table Test for an Re-evaluation of Seismic Fragility of Electrical Cabinet in NPP)

  • 김민규;최인길
    • 한국전산구조공학회논문집
    • /
    • 제24권3호
    • /
    • pp.295-305
    • /
    • 2011
  • 본 연구에서는 원자력발전소의 주요 설비중의 하나인 전기설비를 대상으로 지진취약도 재평가를 위한 진동대 실험을 수행하였다. 원자력발전소 내에는 많은 전기설비들이 설치되어 있으며, 이러한 전기설비의 손상은 전기설비 자체의 손상에서 그치는 것이 아니고 발전소 전체의 안전성에 큰 영향을 미칠 수 있다. 따라서 원자력발전소의 확률론적 지진안전성 평가에서는 주요 전기설비에 대한 지진취약도 결과를 활용한 평가를 수행하고 있다. 본 연구에서는 기존의 확률론적 지진안전성 평가에서 사용하고 있는 전기설비의 지진취약도 값에 대한 재평가를 위하여 원자력발전소에서 사용하고 있는 주요 기기에 대한 진동대 실험을 수행하였다. 평가대상 전기설비로는 480V MCC를 선정하였으며, 진동대 실험을 위하여 NRC 설계지진, 등재해도 스펙트럼에 의한 인공지진 그리고 PAB165'에서의 층응답스펙트럼을 이용한 인공지진의 3가지 지진파를 이용하였다. 설계지진동 수준인 최대지반가속도 0.2g부터 단계적으로 입력수준을 증가시키면서 실험을 수행하였다. NUREG/CR-5203에서 제시하고 있는 방법에 의거하여 캐비넷에서의 증폭비를 비교하였으며, EPRI TR-103959의 방법으로 취약도 평가를 수행하여 기존의 확률론적 지진안전성 평가에서 사용하고 있는 지진취약도 결과와 비교하였다. 결론적으로 기존의 보고서에서 제시하고 있는 취약도 결과가 다소 보수적으로 평가하고 있음을 알 수 있었다.