• 제목/요약/키워드: floor

검색결과 6,097건 처리시간 0.033초

거주자의 거동으로 발생하는 바닥진동의 층간 전달 및 바닥충격음의 음압레벨 특성 평가 (Characteristics of Transmission of Floor Vibration and Floor Impact Noise Due to Human Activities)

  • 이민정;최현기
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.5-13
    • /
    • 2017
  • Noise complaints among neighbors in apartment building are mainly caused by floor impact noise that is structure born noise due to occupant induced floor vibration. To control this noise problems many researchers have investigated floor systems and finishing materials. Light-weight impact noise affects by finishing materials, but heavy-weight impact noise induced by heel impacts during normal walking or jumping of children is concerned with structural system and floor vibration. To figure out the characteristics of floor impact noise and transmission of floor vibration due to human activities, vibration tests were conducted in apartment buildings. Impact hammer, heel drop and walking activities were loaded at center of upstairs living room, and accelerations of slabs for both upstairs and downstairs and sound pressure levels for downstairs were measured. The acceleration ratio of transmitted floor vibration to downstairs and human induced vibration in upstairs was between 0.5 and 1.0 according to slab size, wall, and load type. And floor impact noise occurred in the range of natural frequency of slab.

공동주택 바닥판에 대한 실용적인 진동해석 (Practical Vibration Analysis for the Floor of Dwelling Building)

  • 박강근;김용태;최영화
    • 한국공간구조학회논문집
    • /
    • 제6권1호
    • /
    • pp.65-73
    • /
    • 2006
  • 공동주택의 바닥 슬래브의 합리적인 진동평가를 위하여 보다 정확한 진동해석이 수행되어야 하므로 바닥 슬래브의 시공방법 및 재료에 따라서 상세하게 모델화하여야 한다. 실제 바닥 슬래브의 수치해석에 있어서 매우 상세하게 모델화하여 진동해석을 수행하는 것은 현실적으로 어려우므로 이에 대한 대안으로 본 논문에서 공동주택의 표준바닥 슬래브에 대한 보다 합리적인 수치해석 방법을 제안하였다.

  • PDF

바닥건축재료의 충결하중에 대한 반응 (Impact-Response of Floor Construction Materials)

  • 장상식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제23권2호
    • /
    • pp.83-87
    • /
    • 1995
  • Impact-bouncing height of steel balls dropped from 1m height on various floor materials were measured to evaluate impact-bouncing characteristics depending on floor materials and the effect of these properties on walkability and fatigue of humanbody. Stone and tile finished concrete floor showed the highest bouncing height of around 70%, and soil showed the lowest bouncing height of around 3%. The second highest bouncing height was about 40% which corresponded to terazo finished concrete floor and about twice as high as the bouncing height on concrete floor without finishing. The impact-bouncing height could be lowered to 15~20% by using gum tile on concrete floor. Steel showed similar bouncing height to concrete floor, and wood-based materials showed the second lowest bouncing height next to soil. Among wood-based materials, hardwood species having higher specific gravities showed relatively high bouncing height of 8~24%, softwood species having low specific gravities showed relatively lower bouncing height of 5~18%, and wood composites showed bouncing height of 8~18%. Among all the materials used in this study, wood-based floor materials corresponded to the bouncing height of 10~15% which is considered to be best for humanbody. Surface painting on wood-based materials increased the bouncing height, and the number of bouncing of steel balls after dropping from 1m height increased as the bouncing height increased.

  • PDF

Optimum design of steel floor system: effect of floor division number, deck thickness and castellated beams

  • Kaveh, A.;Ghafari, M.H.
    • Structural Engineering and Mechanics
    • /
    • 제59권5호
    • /
    • pp.933-950
    • /
    • 2016
  • Decks, interior beams, edge beams and girders are the parts of a steel floor system. If the deck is optimized without considering beam optimization, finding best result is simple. However, a deck with higher cost may increase the composite action of the beams and decrease the beam cost reducing the total cost. Also different number of floor divisions can improve the total floor cost. Increasing beam capacity by using castellated beams is other efficient method to save the costs. In this study, floor optimization is performed and these three issues are discussed. Floor division number and deck sections are some of the variables. Also for each beam, profile section of the beam, beam cutting depth, cutting angle, spacing between holes and number of filled holes at the ends of castellated beams are other variables. Constraints include the application of stress, stability, deflection and vibration limitations according to the load and resistance factor (LRFD) design. Objective function is the total cost of the floor consisting of the steel profile cost, cutting and welding cost, concrete cost, steel deck cost, shear stud cost and construction costs. Optimization is performed by enhanced colliding body optimization (ECBO), Results show that using castellated beams, selecting a deck with higher price and considering different number of floor divisions can decrease the total cost of the floor.

뜬바닥구조의 균열강도 평가 (Evaluation of Cracking Strength of Floating Floor System)

  • 이정윤;이범식;전명훈;김종문
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.53-61
    • /
    • 2015
  • 이 연구에서는 층간소음을 억제하기 위하여 사용되는 뜬바닥구조의 구조거동을 실험을 통하여 평가하였다. 최근 층간소음을 억제하기 위하여 연질의 완충재가 사용되며, 이로 인하여 마감모르타르나 기포콘크리트에 균열이 발생할 가능성이 높아지고 있다. 이 연구에서는 완충재의 강성, 하중가력 위치, 바닥 구성층을 변수로 하는 16개의 2방향 뜬바닥구조를 실험하였다. 실험에 의하면 완충재의 강성은 뜬바닥구조의 균열강도에 큰 영향을 미치며 완충재의 할선계수가 0.2MPa인 경우에 낮은 강도에서 균열이 발생하였다. 또한 슬래브의 단부나 모서리에 하중이 가력될 경우에 균열강도가 감소하였다. 뜬바닥구조를 이루고 있는 마감모르타르는 균열강도에 영향을 주었지만 기포콘크리트는 균열강도에 영향을 주지 않았다.

수직진동 사용성을 고려한 플렛플레이트 두께 제안 (Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

급배기 위치에 따른 바닥급기 공조시스템의 냉방 열환경 (Thermal Comfort of the Floor Supply Air Conditioning System for Different Supply-return Locations during Cooling)

  • 김요셉;김영일;유호선
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.476-485
    • /
    • 2000
  • This study numerically investigates thermal comfort in a space cooled by the floor-supply air conditioning system, in which three different supply-return locations, one floor supply-ceiling return and two floor supply-floor returns, are treated. A complementary experiment is peformed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through the diffuser is developed for efficient simulations. The calculated results show that the ceiling return type is far better in thermal comfort than the floor return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor supply-floor return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present estimation.

  • PDF

바닥난방이 육계의 사육환경 및 생산성에 미치는 영향 (Effect of Floor Heating System on Housing Environment and Performance in Broiler Production)

  • 최희철;이덕수;서옥석;한정대;강희설;권두중;곽정훈;강보석;장병귀
    • 한국가금학회지
    • /
    • 제26권3호
    • /
    • pp.189-193
    • /
    • 1999
  • This experiment was conducted to investigate the effect of floor heating system on housing environment and performance in broiler production. PVC heating pipes(in 25cm spacing) were covered with concrete under the litter. Floor heating system was compared with conventional direct heating system. Each treatment had two replicates of 110 birds each. Litter moisture content was significantly reduced in floor heating system than conventional direct heating system(P〈0.05). Dust concentration was higher in floor heating system because of low litter moisture content. CO$_2$concentration was 2,900ppm and 1,500ppm on the direct heating system and floor heating system, respectively at the age of 1 week. Body weight was significantly higher in floor heating system at 7 weeks of age(P〈0.05). The results of the trial show that floor heating was useful heating system for broiler production.

  • PDF

공동주택에서의 바닥충격음 인지도 분석 (The Analysis of Perceptual Levels For Floor Impact Noises in Apartments)

  • 김경호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.598-603
    • /
    • 2002
  • The floor impact noise in apartment buildings has been known as the most sensitively recognized environmental noise. Therefore. inhabitants perceptual evaluation of floor impact noises was investigated by a questionnaire survey. It was found that the respondents perceive the floor impact noises from the upper nor as a constant noise level. However, if there is any child on the upper floor. the respondents felt Its noise as a harshly grating level. It was also found that the larger the respondents house is. the higher their wanted level of noise isolation is. Moreover, it was revealed that the main source of the floor impact noise from the upper floor is a child at the age from six to seven. The results could be used as fundamental data for the research on impact sources and new regulations that fit to Korean perceptual aspects and characteristics.

  • PDF

뜬바닥구조를 이용한 선실 바닥충격음 저감에 관한 연구 (A Study of Floor Impact Noise Reduction of Cabin Using Floating Floor)

  • 김현실;김봉기;차선일;김영수
    • 대한조선학회논문집
    • /
    • 제41권5호
    • /
    • pp.41-47
    • /
    • 2004
  • In this paper, floor impact noise reduction in cruise ship cabin is studied. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t panel is used to construct wall and ceiling inside the steel structure. Various floating floor systems are tested for which normalized impact noise is measured according to ISO 140-7. In addition, floor SBN (Structure-borne Noise) and floor damping are measured to study the effect of floating floor structure. It is shown that VL(Visco-elastic Layer) is more effective when hard plates are added above the VL.