• 제목/요약/키워드: floor

검색결과 6,104건 처리시간 0.028초

산업단지 내 저층과 고층 아파트의 외기 중 호흡성분진과 일산화탄소 수준 (Ambient Levels of CO and PM10 at Low- and High-floor Apartments in Industrial Complexes)

  • 조완근;이준엽
    • 한국환경과학회지
    • /
    • 제15권8호
    • /
    • pp.719-725
    • /
    • 2006
  • Since low-floor apartments ate vertically closer to patting lots and roadways, it is hypothesized that residents in low-floor apartments may be exposed to elevated ambient levels of motet vehicle emissions compared to residents in high-floor apartments. The present study examined this hypothesis by measuring two motor vehicle source-related pollutants(CO and PM10) in ambient air of high-rise apartment buildings within the boundary of industrial complexes according to atmospheric stability The ambient air concentrations of CO and PM10 were higher for low-floor apartments than for high-floor apartments, regardless of atmospheric stability, The median concentration ratio of the low-floor air to high-floor alt ranged from 1.3 to 2.0, depending upon atmospheric stabilities, seasons and compounds. Moreover, the CO and PM10 concentrations were significantly higher in the winter and in the summer, regardless of the Hoot height. Atmospheric stability also was suggested to be important for the residents' exposure of high-rise apartment buildings to both CO and PM10. The median ratios of surface inversion air to non-surface inversion air ranged from 1.2 to 1.7 and from 1.0 to 1.6 lot PM10 and CO, respectively, depending upon seasons. Conclusively, these parameters(apartment floor height, season, and atmospheric stability) should be considered when evaluating the exposure of residents, living in high-rise apartment buildings, to CO and PM10. Meanwhile, the median PMl0 outdoor concentrations were close to or higher than the Korean annual standards for PM10, and the maximum PM10 concentrations substantially exceeded the Korean PM10 standard, thus suggesting the need for a management strategy for ambient PM 10. Neither the median nor the maximum outdoor CO concentrations, however, were higher than the Korean CO standard.

Sensory change and recovery of infraorbital area after zygomaticomaxillary and orbital floor fractures

  • Sang Woo, Han;Jeong Ho, Kim;Sug Won, Kim;Sung Hwa, Kim;Dae Ryong, Kang;Jiye, Kim
    • 대한두개안면성형외과학회지
    • /
    • 제23권6호
    • /
    • pp.262-268
    • /
    • 2022
  • Background: To compare the sensory change and recovery of infraorbital area associated with zygomaticomaxillary and orbital floor fractures and their recoveries and investigate the factors that affect them. Methods: We retrospectively reviewed 652 patients diagnosed with zygomaticomaxillary (n= 430) or orbital floor (n= 222) fractures in a single center between January 2016 and January 2021. Patient data, including age, sex, medical history, injury mechanism, Knight and North classification (in zygomaticomaxillary fracture cases), injury indication for surgery (in orbital floor cases), combined injury, sensory change, and recovery period, were reviewed. The chi-square test was used for statistical analysis. Results: Orbital floor fractures occurred more frequently in younger patients than zygomaticomaxillary fractures (p< 0.001). High-energy injuries were more likely to be associated with zygomaticomaxillary fractures (p< 0.001), whereas low-energy injuries were more likely to be associated with orbital floor fractures (p< 0.001). The sensory changes associated with orbital floor and zygomaticomaxillary fractures were not significantly different (p= 0.773). Sensory recovery was more rapid and better after orbital floor than after zygomaticomaxillary fractures; however, the difference was not significantly different. Additionally, the low-energy group showed a higher incidence of sensory changes than the high-energy group, but the difference was not statistically significant (p= 0.512). Permanent sensory changes were more frequent in the high-energy group, the difference was statistically significant (p= 0.043). Conclusion: The study found no significant difference in the incidence of sensory changes associated with orbital floor and zygomaticomaxillary fractures. In case of orbital floor fractures and high-energy injuries, the risk of permanent sensory impairment should be considered.

A Study on Floor Impact Sound Insulation Performance of Cross-Laminated Timber (CLT): Focused on Joint Types, Species and Thicknesses

  • Yeon-Su HA;Hyo-Jin LEE;Sang-Joon LEE;Jin-Ae SHIN;Da-Bin SONG
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권5호
    • /
    • pp.419-430
    • /
    • 2023
  • In this study, the floor impact sound insulation performance of Korean domestic Cross-Laminated Timber (CLT) slabs was evaluated according to their joint types, species and thicknesses in laboratory experiments. The sound insulation performance of the CLT has not been investigated before, thus, this study was conducted to quantify basic data on floor impact sound insulation performance of CLT slabs. 5-ply and 150 mm thick CLT panels made of 2 species, Larix kaempferi and Pinus densiflora, were used for the study. The CLT panels were assembled by 3 types of inter-panel joints to form floor slabs: spline, butt and half-lap. And the 150 mm thick Larix CLT slabs were stacked to the thicknesses of 300 mm and 450 mm. The heavy-weight floor impact sound insulation performance of the 150 mm CLT slabs were evaluated to be 70 dB for the Larix slabs and 71.6 dB for the Pinus slabs, and the light-weight floor impact sound insulation performance, 78.3 dB and 79.6 dB, respectively. No significant difference in the sound insulation performance was found between the slabs of the 2 species or among the 3 types of joints. The reduction of 1 dB in the heavy-weight floor impact sound and 1.6 dB in the light-weight floor impact sound per 30 mm increase in thickness were confirmed through the experiments. This study can be viewed as the basic research for the evaluation of floor impact sound insulation performance of CLT.

EVA 완충재의 형상변환을 통한 복합구조의 바닥충격음 변이 조사 (Investigation of the level difference of floor impact noises through the shape variation of EVA resilient materials with composite floor structure)

  • 이야긴;이승민;한찬훈
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.60-71
    • /
    • 2024
  • 본 연구는 일반적인 평평한 에틸렌 비닐 아세테이트(Ethylen Vinyl Acetate, EVA) 완충재의 형상을 변화시켜 다양한 차음소재와 조합하여 복합구조의 바닥충격음 변화를 조사하는 데에 목적이 있다. 바닥충격음 저감에 효과적인 완충재를 선정하기 위해 Flat, Deck, Cavity type의 EVA, EPS, PET 흡음재, PP판넬, 고무발판 등 다양한 완충재를 조합하여 뱅머신을 이용한 1차 실험을 진행하였다. 1차 실험 데이터에 대해 통계분석한 결과 완충재 두께가 40 mm에 가까울수록 바닥충격음 저감효과가 증가하였으며 PET 흡음재, PP시트, 고무발판 등을 조합한 복합완충재에서 바닥충격음 효과가 증가하는 것을 알 수 있었다. 이에따라 2차 실험에서 모든 복합완충재의 두께는 40 mm로 통일하였으며, 1차 실험에 사용된 Flat, Deck, Cavity type 및 EVA를 발판형태로 가공한 Mount type 등 4가지 형태의 복합완충재를 설계하였다. 또한, Mount type을 제외한 3가지 기본 형태에서 각각 PET 흡음재(7 mm)를 추가했을 시 바닥충격음 변화를 살펴보았으며, Mount type의 경우 EVA발판 개수에 따른 바닥충격음 변화에 대해 고무공 충격원을 이용한 2차 실험을 진행하였다. 모든 실험은 공인인증시험기관의 목업실험실에서 진행하였다. 실험 결과, 기본형태의 Flat, Deck, Cavity type에서 PET를 추가할 경우 통계적으로 경량 5 dB ~ 9 dB, 중량 1 dB ~ 5 dB의 저감효과가 나타난 것을 알 수 있었다. 특히, Mount type의 경우 발판 수가 36개 이상일 때 경량 및 중량충격음에서 우수한 것으로 나타났다. 또한, 4가지 기본형태에 따라 동탄성계수가 높아질수록 바닥충격음의 저감이 증가하는 것으로 나타났다.

공동주택의 소음 저감재 설치로 인한 바닥 충격음에 관한 연구 (A Study on Floor Impact Sound due to Resilient Materials in Apartment Buildings)

  • 김병길;김수련;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.5-10
    • /
    • 2004
  • Apartment Buildings have particularity to cluster together, especially, floor is close to resident, it is subject to dissatisfaction about impact noise between up and down floors. However, we require standard for counterplan to reduce the impact noise of floor. In point of fact, it difficult to objective evaluate for performance sound insulation that not physical sound volume but orignal form, means and effect of sound caused to complex noise in apartment house. Unique type of dwelling and structure pattern cause to noise of floor impact which is established by law for standard regulation. It is object to analysis and compare the result of performance sound insulation of upper floor impact and sample construct the subject resilient material of sound insulator

  • PDF

생산 현장 중심의 설계/생산 통합 정보 시스템 개발 (The Development of a Shop Floor-Centered Information System for the Integration of Design and Manufacturing Data)

  • 한관희;박찬우;옥주선;김갑산
    • 한국CDE학회논문집
    • /
    • 제10권4호
    • /
    • pp.237-243
    • /
    • 2005
  • To increase the productivity and efficiency of an enterprise, all relevant product information should be provided to shop floor workers timely and in a unified form because shop floor workers are final consumers of most accumulated information generated from various departments of an enterprise. But, most existing enterprise information systems have an emphasis upon providing design/manufacturing information to office workers. Proposed in this study is the development of integrated design/manufacturing information system focused on providing cohesive information required to shop floor activities. For developing integrated information system, the functional requirements at the shop floor are identified and analyzed. Based on the extracted functional requirements, object-oriented system design and implementation is conducted. By using this system, shop floor workers can use all relevant information required to their daily operation in a integrated and unified form.

A simplified method for determining the acceleration amplitudes of long-span floor system under walking/running loads

  • Cao, Liang;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • 제75권3호
    • /
    • pp.377-387
    • /
    • 2020
  • Modern long-span floor system typically possesses low damping and low natural frequency, presenting a potential vibration sensitivity problem induced by human activities. Field test and numerical analysis methods are available to study this kind of problems, but would be inconvenient for design engineers. This paper proposes a simplified method to determine the acceleration amplitudes of long-span floor system subjected to walking or running load, which can be carried out manually. To theoretically analyze the acceleration response, the floor system is simplified as an anisotropic rectangular plate and the mode decomposition method is used. To facilitate the calculation of acceleration amplitude aP, a coefficient αwmn or αRmn is introduced, with the former depending on the geometry and support condition of floor system and the latter on the contact duration tR and natural frequency. The proposed simplified method is easy for practical use and gives safe structural designs.

현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발 (A Study on the Development of Rolled Dry Floor Heating System for Improving Workability)

  • 이규동;김준호;정창호;김동우;小川慶一郞
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

항공기 기체 부품 생산을 위한 생산 현장 중심의 설계 생산 통합 / 정보 시스템 개발 (Development of a Shop Floor-Centered Integrated Design/Manufacturing Information System for the Production of Aerospace Structure Parts)

  • 한관희;최운집;박찬우;이상한
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1007-1012
    • /
    • 2004
  • To increase the productivity and efficiency of an enterprise, all relevant product information should be provided to shop floor workers timely and in a unified form because shop floor workers are final consumers of most accumulated information generated from various departments of an enterprise. but, most existing enterprise information systems have an emphasis upon providing design/manufacturing information to office workers. Proposed in this study is a development of integrated design/manufacturing information system focused system, the function required for shop floor activities. For developing integrated information system, the functional required for shop floor are identified and analyzed. Based on the extracted functional requirements, object-oriented system design and implementation is conducted. By using this system, shop floor workers can refer to all relevant information necessary to their work easily and in a integrated form.

  • PDF

중국 연변 조선족과 한족피 집합주택 평면구성 비교 연구 - 연길시를 중심으로 - (The Comparison of Space Origination between Korean-Chinese and Chinese Multi-family Housing in China)

  • 김종영
    • 한국주거학회논문집
    • /
    • 제15권4호
    • /
    • pp.55-63
    • /
    • 2004
  • The aims of this research are to find the difference of space origination between Korean-Chinese and Chinese multi-family housing unit plan and to find the main reason to make this difference. To do this research, twenty three different kinds of floor plans were surveyed and examined. The results are as follows; 1. The Chinese-Korean floor plan and Chinese floor plan in Ondol heating system are totally different, although in radiator and floor panel heating system are similar. The inner space origination between two races are different. That is to say, Chinese-Korean likes open space origination and Chinese likes closed space origination. 2. The main reasons to make differences seem to be living style, heating system, constructional method and the trade with South Korea. In the future time, the usage of floor panel heating system will be increased and various kinds of floor plan should be introduced.