• Title/Summary/Keyword: floating laboratory

Search Result 111, Processing Time 0.024 seconds

토양 및 지하수 Investigation 과 Remediation에 대한 현장적용

  • Wallner, Heinz
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.44-63
    • /
    • 2000
  • Situated close to Heathrow Airport, and adjacent to the M4 and M25 Motorways, the site at Axis Park is considered a prime location for business in the UK. In consequnce two of the UK's major property development companies, MEPC and Redrew Homes sought the expertise of Intergeo to remediate the contaminated former industrial site prior to its development. Industrial use of the twenty-six hectare site, started in 1936, when Hawker Aircraft commence aircraft manufacture. In 1963 the Firestone Tyre and Rubber Company purchased part of the site. Ford commenced vehicle production at the site in the mid-1970's and production was continued by Iveco Ford from 1986 to the plant's decommissioning in 1997. Geologically the site is underlain by sand and gravel, deposited in prehistory by the River Thames, with London Clay at around 6m depth. The level of groundwater fluctuates seasonally at around 2.5m depth, moving slowly southwest towards local streams and watercourses. A phased investigation of the site was undertaken, which culminated in the extensive site investigation undertaken by Intergeo in 1998. In total 50 boreholes, 90 probeholes and 60 trial pits were used to investigate the site and around 4000 solid and 1300 liquid samples were tested in the laboratory for chemical substances. The investigations identified total petroleum hydrocarbons in the soil up to 25, 000mg/kg. Diesel oil, with some lubricating oil were the main components. Volatile organic compounds were identified in the groundwater in excess of 10mg/l. Specific substances included trichloromethane, trichloromethane and tetrachloroethene. Both the oil and volatile compounds were widely spread across the site, The specific substances identified could be traced back to industrial processes used at one or other dates in the sites history Slightly elevated levels of toxic metals and polycyclic aromatic hydrocarbons were also identified locally. Prior to remediation of the site and throughout its progress, extensive liaison with the regulatory authorities and the client's professional representatives was required. In addition to meetings, numerous technical documents detailing methods and health and safety issues were required in order to comply with UK environmental and safety legislation. After initially considering a range of options to undertake remediation, the following three main techniques were selected: ex-situ bioremediation of hydrocarbon contaminated soils, skimming of free floating hydrocarbon product from the water surface at wells and excavations and air stripping of volatile organic compounds from groundwater recovered from wells. The achievements were as follows: 1) 350, 000m3 of soil was excavated and 112, 000m3 of sand and gravel was processed to remove gravel and cobble sized particles; 2) 53, 000m3 of hydrocarbon contaminated soil was bioremediated in windrows ; 3) 7000m3 of groundwater was processed by skimming to remove free floating Product; 4) 196, 000m3 of groundwater was Processed by air stripping to remove volatile organic compounds. Only 1000m3 of soil left the site for disposal in licensed waste facilities Given the costs of disposal in the UK, the selected methods represented a considerable cost saving to the Clients. All other soil was engineered back into the ground to a precise geotechnical specification. The following objective levels were achieved across the site 1) By a Risk Based Corrective Action (RBCA) methodology it was demonstrated that soil with less that 1000mg/kg total petroleum hydrocarbons did not pose a hazard to health or water resources and therefore, could remain insitu; 2) Soils destined for the residential areas of the site were remediated to 250mg/kg total petroleum hydrocarbons; in the industrial areas 500mg/kg was proven acceptable. 3) Hydrocarbons in groundwater were remediated to below the Dutch Intervegtion Level of 0.6mg/1; 4) Volatile organic compounds/BTEX group substances were reduced to below the Dutch Intervention Levels; 5) Polycyclic aromatic hydrocarbons and metals were below Inter-departmental Committee for the Redevelopment of Contaminated Land guideline levels for intended enduse. In order to verify the qualify of the work 1500 chemical test results were submitted for the purpose of validation. Quality assurance checks were undertaken by independent consultants and at an independent laboratory selected by Intergeo. Long term monitoring of water quality was undertaken for a period of one year after remediation work had been completed. Both the regulatory authorities and Clients representatives endorsed the quality of remediation now completed at the site. Subsequent to completion of the remediation work Redrew Homes constructed a prestige housing development. The properties at "Belvedere Place" retailed at premium prices. On the MEPC site the Post Office, amongst others, has located a major sorting office for the London area. Exceptionally high standards of remediation, control and documentation were a requirement for the work undertaken here.aken here.

  • PDF

A STUDY OF THE IONOSPHERIC ELECTRON MEASUREMENT ON THE MEDIUM-SIZED SCIENTIFIC ROCKET , KSR-II (중형과학로켓, KSR-II를 이용한 이온층 전자 밀도 및 온도 분포 측정에 관한 연구)

  • Lee, Jae-Jin;Kim, Jhoon;Lee, Soo-Jin;Min, Kyoung-Wook;Pyo, You-Surn;Cho, Gwang-Rae;Rhee, Hwang-Jae
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.401-415
    • /
    • 1998
  • This paper reports the results obtained from the Langmuir probe (LP) and Electron Temperature Probe (ETP) experiments on the sounding rocket KSR-II (Korean Scientific Rocket - II) which was launched on Jun 11, 1998 at 10:00 KST from Tae-An peninsula (37$^{\circ}$ N, 126$^{\circ}$ E). The instruments successfully measured the electron density, electron temperature, and the floating potential at altitudes of 73km to 130km. While the electron temperature measurement is not easy in this region, since the temperature is very low and the contamination effect of the probe may give rise to a problem, we were able to obtain a reasonable electron temperature profile by employing two independent methods, the pulse modulated Langmuir Probe and Electron Temperature Probe. The preliminary results show that electron density increases sharply at about 90km, and forms a peak at 102km. The density profile is roughly consistent with IRI (International Reference Ionosphere)95-model or PIM (Parameterized Ionospheric Model) results except that the peak density appears at 110km in the model and model electron density is slightly lower than the observed one. Electron temperature obtained from ETP fluctuates between 200$^{\circ}$K and 700$^{\circ}$K, an effect presumably coming from the wakes developed by LP, and it tends to increase with the altitude, which is consistent with the LP results.

  • PDF

Control Effects against Mosquitoes Larva of Bacillus thuringiensis subsp. israelensis CAB199 isolate according to Different Formulations (Bacillus thuringiensis subsp. israelensis CAB199균주의 제형에 따른 모기유충방제 효과)

  • Seo, Mi-Ja;Gil, Yeong-Jong;Kim, Tae-Hwan;Kim, Hyung-Joong;Youn, Young-Nam;Yu, Yong-Man
    • Korean journal of applied entomology
    • /
    • v.49 no.2
    • /
    • pp.151-158
    • /
    • 2010
  • Among 18 Bacillus thuringiensis isolates with spherical parasporal inclusion from soils, B. thuringiensis subsp. israelensis CAB199 was selected. It was showing over 90% mortality against Aedes aegypti and Culex pipiens moletus. It was confirmed that this B. thuringiensis subsp. israelensis CAB199 isolate also had a insecticidal activity against Culex inatomii that was occurred in the marsh. Because most of mosquito larva were primarily situated or shifted from under- to surface water, we need to select long floating formulations on surface water for controlling mosquito larva. It was tested the pesticidal and control effects in the laboratory and wetland with two formulation types of B. thuringiensis subsp. israelensis, for example, wettable power (WP) and suspension concentrate type (SC). Laboratory test showed that SC formulation type was relatively faster and more effective against 3 tested mosquito species, C. pipiens, Aedes aegypti, and C. inatomii. Otherwise, the control efficacy of SC formulation type was more rapidly appeared against C. inatomii in the wetland.

A Study on Real-time Implementing of Time-Scale Modification (음성 신호 시간축 변환의 실시간 구현에 관한 연구)

  • Han, Dong-Chul;Lee, Ki-Seung;Cha, Il-Hawan;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.50-61
    • /
    • 1995
  • A time scale modification method yielding rate-modified speech while conserving the characteristic of speech was implemented in real-time using a goneral purpose digital signal processor. Time scale modification changed pronunciation speed only, producing a time difference between the input signal and the modified signal, making it impossible to implement it in real-time. In this thesis, a system was implemented to remove the time difference between the input and modified signals. Speech signals slowed down or speeded up by a physical time scale modification method, such as adjusting the motor speed of the cassett tape recorder, was used as the input signal. Physical modification that controled only the inter speed of the cassette tape player distorted the pitch period of the original speech. In this study, a real-time system was implemented so that the pitch-distorted speech was reconstructed back to the original by fractional sampling pitch shifting using an FIR filter, and this signal was time scale modified to match the cassette tape recorder motor speed using SOLA time-scale medification. In experiments using speech signals medifiedby the proposed method, results obtained using a 16-bit resolution ADSP2101 processor and using computer simulations employing floating point operations showed about the same average frame signal-to-noise ratio of about 20 dB.

  • PDF

Quality Evaluation of Commercial Extruded Pellet Diet for Olive Flounder, Paralichtys olivaceus (시판 넙치용 배합사료의 품질평가)

  • JI Seung Cheol;MOON Gyeong Su;YOO Jin Huyng;LEE Si Woo;KIM Hong Beom;JEONG Gwan Sik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.38 no.5
    • /
    • pp.291-297
    • /
    • 2005
  • This study evaluated the quality of commercial extruded pellet (EP) diet of five companies (A, B, C, D and E) for olive flounder Paralichtys olivaceus by biochemical analyses, physical properties and growth performance. The proximate analyses of five EP diets showed $3.2-10.0\%$ of moisture, $49.3-55.5\%$ of crude protein, $4.6-14.7\%$ of crude lipid, $7.0-13.8\%$ of crude ash, $0.7-10.5\%$ of crude fiber, $10.0-27.3\%$ of itrogen free extract (NFE), 304.3-395.4kcal/100g of digestible energy (DE) and 6.1-7.1 of calorie/protein ratio (C/P). Peroxide value (POV) was highest in diet D (47.4 meq/kg) as compared to other diets which in the range of 4.0-11.7 meq/kg. Total amino acid contents were ranged from 46.54 to $55.46\%$ with the highest content in diet B and the lowest content in diet C. Essential amino acid of diet C was lowest $(7.43\%)$ as compared to other diets which in the range of $19.43-20.30\%$. Saturated fatty acid was higher in diet A $(37.65\%)$ followed by diet B $(36.32\%)$, diet E$(34.39\%)$, diet C$(30.95\%)$ and diet D$(30.10\%)$. EPA+DHA were highest in diet E$(30.78\%)$ and lowest in diet C$(15.48\%)$. The floating rate after 6 hours on the sea water was highest in diet C$(100\%)$ followed by diet B$(40\%)$ and A$(10\%)$. However, diets D and E were completely settled down after 1 and 2 hours, respectively. The range of relative expansion rate was $27.2-49.3\%$ for all diets and all reached the peak at 2-3 hours. The water absorption rate of diets C and D was lowest, and diet E was highest at 1 hour after deposition of sea water. Growth rate was higher in diet B$(22.3\%)$ and E$(21.3\%)$. Feed efficiency was higher in diet A$(109.7\%)$ and E$(105.3\%)$ and was significantly lowest in diet D$(80.7\%)$. The protein efficiency ratio was highest in diet E (2.72) and lowest in diet D (1.76). These results suggest that there is a necessity for improvement of nutrients balance and feed physical properties to fulfill the nutrient requirements and digestive characteristics of fishes in commercial EP diets.

Electrical Output and Reliability of Photovoltaic Module Using Ethylene Tetrafluoroethylene Film (ETFE 필름을 적용한 태양광 모듈의 전기적 출력 및 신뢰성에 관한 연구)

  • Shin, Woogyun;Lim, Jongrok;Ko, Sukwhan;Kang, Gihwan;Ju, Youngchul;Hwang, Heymi
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.4
    • /
    • pp.13-22
    • /
    • 2020
  • As the supply of photovoltaic (PV) increases worldwide, the cumulative installations in 2018 were 7.9 and 560 GW in Korea and the world, respectively. Typically, when the ground on commercial PV modules is installed, the area is limited; hence, new designs of PV modules are required to install additional PVs. Among the new design of PV modules, lightweight PV modules can be utilized in PV systems, such as buildings, farmlands, and floating PV. Concerning the investigation of lightweight PV modules, several studies on materials for replacing low-iron tempered glass, which comprises approximately 65% of the PV module weight, have been conducted. However, materials that are used as substitutes for glass should possess similar lightweight properties and reliability as glass. In this study, experimental tests were performed to evaluate the applicability of ethylene tetrafluoroethylene (ETFE) film with excellent resistance to water and aging as a front material of PV modules. The transmittance and ultraviolet properties of the ETFE film were determined and compared with those of glass. A 1-cell module and laboratory-scale 24-cell module were manufactured using the ETFE film and glass, and the electrical output was measured and analyzed. Furthermore, damp heat and thermal cycle tests were conducted to evaluate the reliability of the ETFE film module. Based on the experimental results, the electrical output and reliability of the ETFE film module were similar to those of the glass module, and the ETFE film could be used as the front material of PV modules.

A Study on the Sea Water DTEC Power Generation System of the FPSO (FPSO의 온배수를 활용한 해수 DTEC 발전시스템에 대한 연구)

  • Song, Young-Uk
    • Journal of Navigation and Port Research
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2018
  • The development of limited petroleum resources for use with mankind inevitably explores and seeks to develop oil fields in the deep sea area, under the rise of the oil prices market situation. The use of Oceanic Thermal Energy Conversion (OTEC) technology, which operates the power generation facility using the temperature differences between the deep water and the surface water, is progressing actively as a trend to follow. In this study, the application of the Discharged Thermal Energy Conversion (DTEC) was designed and analyzed under the condition that the supply condition of seawater used in the FPSO installed in the deep sea area is changed up to 400m depth. In this case, it was confirmed that the design of the system that can generate more electric power according to the depth of water is confirmed, by thus applying the DTEC system by taking the cooling water at a deeper water depth than the existing design water depth. The FPSO considers the similarity of the OTEC power generation facilities, and will apply the DTEC system to FPSO in the deep sea area to accumulate technology and the conversion to further utilize the OTEC power generation facilities after the end of life cycle of oil production, which could be a solution to two important issues, namely, resource development and sustainable development.

Change in the Wetland Vegetation Structure after the Ecological Restoration (생태복원 습지의 조성 후 식생구조 변화)

  • Kim, Na-Yeong;Song, Young-Keun;Lee, Kun-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.6
    • /
    • pp.95-113
    • /
    • 2018
  • We studied the change of wetland vegetation structure to understand ecological restoration process of wetlands through the field survey of ecological restoration projects in Incheon, Iksan and Busan. We compared the vegetation plan at the time of planted with the results of the vegetation monitoring in 2018, and analyzed the changes in wetland vegetation structure. Based on results, we attempted to understand the restoration process of those wetlands and discuss the management measures for sustainable wetland restoration. As a result, in the Incheon Yeonhee restoration wetland, the number of plant species was increased, from 18 species in 2016 to 29 in 2018. The dominant species, Myriophyllum verticillatum, covered the wetland most and its occupied area was increased. On the other hand, the distribution area of the planted emergent hydrophytes was reduced. The area of open water decreased from 71.7% in 2016 to 48.8% in 2018. In Busan Igidae restoration wetland, the number of plant species was increased, from 6 species in 2014 to 31 in 2018. The dominant species was Myriophyllum verticillatum and its occupied area was increased. The area of floating plant communities that planned has decreased. The open water area decreased from 83.9% in 2014 to 31.8% in 2018. In Iksan Sorasan restoration wetland, the number of plant species was increased, from 13 species in 2016 to 36 in 2018. The dominant species was Phragmites communis Trin. and its occupied area was increased. The other planted species showed a tendency to be decreased by Phragmites communis Trin. and its terrestrialization. The open water area decreased from 86.6% in 2016 to 6.7% in 2018. These results suggest that wetlands should be managed by considering the change of vegetation structure and open water areas based on the following succession process, because it affects the habitat suitability of wetland organisms and biodiversity as well. Thus, the continuous monitoring for the ecological structure of restored wetland is important, and it could be possible step to develop sustainable wetland ecological restoration model.

An Experimental Study on the Performance of Expandable Steel Pipe Pile (확장형 강관말뚝의 성능에 대한 실험적 연구)

  • Kim, Junghoon;Kim, Uiseok;Kim, Jiyoon;Kang, Minkyu;Choi, Hangseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Expandable steel pipe piles are installed by inserting expansion equipment to increase the cross-sectional area of steel pipes, which can improve the pile performance compared to micro-piles. In this paper, a hydraulic expansion device was developed to expand steel pipe piles in practice. A series of laboratory and field tests were conducted to verify the performance of the developed expansion device to expand steel pipes. The expansion capability and expandable range was evaluated by measuring the strain and expansion time at the maximum pressure of the hydraulic expansion device. The thinner steel pipe, the larger strain but longer expansion time required in the test. For example, the 4.0-mm-thick steel pipe showed strain reduction by 30% and a decrease in the required expansion time by 40% compared to the 2.9-mm-thick steel pipe. In addition, in-situ expansion tests were performed to verify the expandability of steel pipes under the ground, and the exhumed specimen showed clear expanded sections. The structural integrity was determined by comparing the material performance the original and expanded specimens.

Assessment of dust exposure and personal protective equipment among dental technicians (치과기공사의 분진노출 수준 및 개인보호구 착용 실태 - 대구지역을 중심으로 -)

  • Park, Soo-Chul;Jeon, Man-Joong;SaKong, Joon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.93-102
    • /
    • 2011
  • Purpose: The study aimed to evaluate working environment for dental technician by measuring dust level, ventilation conditions and the use of personal protective equipment and to provide basic information required to improve working environment and develop health education programs for dental technician. Methods: A total of 240 dental technician who are registered with the Daegu Association of Dental technician and working at 34 dental laboratories participated in the study. And the dust level was measured at 21 different spots in 16 dental laboratories out of 34. Results: Of 34 dental laboratories, 31 (91.2%) were equipped with a ventilator, but the remaining 3 (8.8%) did not have a ventilator. By the number of ventilator, 1 to 3 ventilators were found in 22 dental laboratories (71.0%), 4 to 6 ventilators were in 7 laboratories (22.5%) and more than 7 ventilators in 2 laboratories(6.5%). According to the frequence of changing filters in dust collector, 20 dental laboratories (58.9%) changed filters every four weeks, 10 laboratories (29.4%) changed them every six weeks and 4 laboratories (11.7%) changed them every eight weeks. Of total respondents, 114 (61.3%) said they wore a mask all the time while working, 56 (29.6%) said they frequently wore a mask, 19 (10.1%) said they did not wear a mask. As for the type of masks, 159 (84.1%) used a disposable mask, 25 (13.2%) used a cotton mask and 5 (2.7%) used an anti-dust mask. For dust sat on their outfits while working, 102 (54.0%) shook their uniforms inside workplace to keep dust off the uniforms, 64 (33.9%) did not anything until they wash their uniforms and 23 (12.1%) shook their uniforms outside workplace to keep dust off the uniforms. Of total respondents, 182 (96.3%) had a particle in their eyes while carrying out grinding work. Based on the measurement of floating dust at workplace, 3 dental laboratories showed dust concentration exceeding the minimum level of 10 mg/$m^3$ allowed under the permit for environment. Of those, 1 laboratory had the dust concentration that was more than 1.5 times higher than the minimum level. Dust concentration was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Dust comprised of nickel (more than 70%), chrome (9%) and others. The mean chrome concentration was more than twice higher than the minimum permissible level of 0.5 mg/$m^3$. There were two laboratories that showed chrome concentration exceeding the level of 0.4 mg/$m^3$. Like dust concentration, chrome level was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. There were six laboratories that had nickel concentration exceeding the minimum permissible level of 1 mg/$m^3$. Of those, one laboratory had nickel concentration that was more than three times higher than the minimum permissible level. Nickel concentration was also higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Conclusion: It is not likely that heavy metal concentrations found in the study constitute respiratory dust. It is however necessary for health of dental technician to apply the Industrial Safety and Healthy Law to dental laboratories and make recommendations for the use of personal protective equipment, installation of a proper number of ventilators, more frequent change of filters in dust collector and improved ventilation for polishing work. At the same time, dental technician need education on how to use personal protective equipment and how to efficiently remove dust from their uniforms.