• Title/Summary/Keyword: floating and sinking method

Search Result 13, Processing Time 0.021 seconds

Analysing of pulse wave parameter and typical pulse pattern for diagnosis in floating and sinking pulses (${\cdot}$ 침맥 진단에 유용한 맥상 파라메터 및 대표맥상 분석)

  • Lee, Yu-Jung;Lee, Jeon;Choi, Eun-Ji;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.93-101
    • /
    • 2006
  • Pulse feeling is one of the most important diagnosis method in Oriental medicine. But it is not easy to make an objective and standardized diagnosis. In this study, we found how to quantify diagnosis. Specially dally the high practicality in clinic, we search some parameters especially well-related to floating and sinking pulse by statistic analysis. By extension, we find the pulse patterns of the floating and sinking pulse. We choose 15 subjects diagnosed as floating pulse and 15 subjects diagnosed as sinking pulse by oriental doctors. And their pulse signals were acquired by Pulse analyzer which has piezoresistive pressure sensor. For the quantification of the floating and sinking pulse, at first, we examined the parameters which were highly correlated with oriental doctor's diagnosis. And then we derived pulse patterns of the floating-sinking pulse from preprocessed signal and its ensemble average. We also looked trend variation (PH-Curve) between contact and pulse pressure. As a result, statistically there is the biggest difference between contact pressure, the maximum pulse pressure, diastolic area (Ad) and floating and sinking data. Through the PH-Curve, which represented the relationship between contact and pulse pressure, we could divide the floating and sinking pulse clearly. As a basic research of pulse diagnosis algorithm, we can contribute to select essential parameters in diagnosis algorithm And using these diagnosis method, we expect to find typical pulse patterns and some useful parameters about other pulses like slow/rapid, large/fine pulse and so on. We hope that this study will contribute pulse objectification.

  • PDF

Study on the Selection of Representative Pulse Wave

  • Kim, Jong-Yeol;Shin, Sang-Hoon
    • The Journal of Korean Medicine
    • /
    • v.29 no.5
    • /
    • pp.104-110
    • /
    • 2008
  • Objectives : The purpose of this study is to develop the method of selecting representative pulse wave. Methods : The pulse waves were acquired at the right and the left Guan point(關部) with 1420 people who were apparently healthy. The shape agreement of right and left pulse wave and the floating-sinking ratio were compared with three cases, which were the pulse height based method, the pulse area based method, and the pulse time based method. Results : In the point of the shape accordance, the pulse time based method was the best, and the pulse area based method was the worst. In the point of the floating-sinking ratio, the pulse height based method was the worst, and the pulse time based method was the best. Conclusions : So, the pulse time based method was recommended for selecting the representative pulse wave. This study compared the selection methods of representative pulse using the physiological characteristics of pulse wave. Further studies are required, because the representative pulse wave is the main factor of determining the shape and the floating-sinking characteristic of the pulse wave.

  • PDF

New Algorithm of Determining the Floating and Sinking Pulse with a Pulse Diagnosis Instrument (맥진기를 이용한 새로운 부침맥 판단 방법)

  • Kim, Sung-Hun;Kim, Jae-Uk;Lee, Yu-Jung;Kim, Keun-Ho;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1221-1225
    • /
    • 2009
  • The pulse diagnosis is an important and universally used method in Oriental Medicine. Since the traditional method of palpating the pulse relies on the subjective sense in the fingers of an Oriental Medical Doctor(OMD), there has been continued need for more objective method for pulse diagnosis. Recently, various pulse analyzers have been developed to meet such objective palpation and interpretation. However, most of these attempts were not successful to replace OMD's own palpation by fingers. To improve the performance of the pulse analyzers, one should develop machine-appropriate interpretations for the pulse images in the literature, in addition to the improvement in the repeatability and reproducibility. One of such widely-used pulse images to be interpreted is the floating and sinking pulse. The floating and sinking pulses are the two representative pulse images informing us how strong pressure one should apply to obtain the maximal pulse strength. A previous study suggested a convenient and unified measure for the floating and sinking pulses by defining the coefficient of the floating-sinking pulse(CFS). We found the original definition of the CFS could be erroneous under some situations. To improve the performance, we introduce new CFS algorithm for determining the floating and sinking pulse with a pulse analyzers(3-D MAC). To test the performance of the newly suggested algorithm, we conducted a clinical study comparing the agreement ratio with the floating and sinking pulse diagnosis by the OMDs. We found that, among the subjects who are diagnosed with having either the floating pulse or sinking pulse, the new CFS algorithm showed 55.3% diagnosis rate and 73.0% concordance rate, which are about 3% and 6% improvement in the diagnosis rate and agreement rate, respectively, compared to the original CFS algorithm.

Clinical Study of the Floating-Sinking Pulse Quantification Analysis on Ages, Left/Right, and Palpation Positions (20/60대 여성을 중심으로 살펴본 좌우 촌관척 부/침맥 정량화 임상연구)

  • Kim, Jae-Uk;Kim, Sung-Hun;Jeon, Young-Ju;Ryu, Hyun-Hee;Lee, Yu-Jung;Lee, Hae-Jung;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1193-1198
    • /
    • 2009
  • Pulse diagnosis is a central diagnosis method used in traditional Oriental medicine. To standardize and modernize the pulse diagnosis method, it is essential to develop an instrument-based reinterpretation of the clinically used pulse images in terms of the physical quantities such as the strength, period, width, length, and depth of the pulse. As a step towards such standardization, we conducted a clinical study on the floating/sinking pulses based on an automated palpation instrument (3D-MAC, Daeyo Medi, Korea) for 213 female subjects in their 20s and 174 female subjects in their 60s. The floating/sinking pulses are the two representative pulse images depending only on the depth of the pulse, and can be conveniently scaled by the coefficient of the floating-sinking pulse ($C_{fs}{\in}(0,1)$), which represents how strong one should apply the hold-down pressure to obtain the maximal pulse strength. As a result, primarily we found that it tends to appear more floating-like pulse ($C_{fs}{\rightarrow}0$) at Gwan and more sinking-like pulse ($C_{fs}{\rightarrow}1$) at Cheek, at both age groups and at both wrists. This result is consistent with a previous study on the geometrical structure of the blood vessel by an ultrasonograph. Second, the pulse tends to be more sinking-like in the age group of 60s than 20s. Finally, the pulses at the right palpation positions were found to be more sinking-like than the left, at both age groups.

Clinical Study on the Floating and Sinking Pulse Detection with Piezoresistive Sensors and Contact Pressure Control Robot (압저항 센서와 가압조절 로봇을 이용한 부침맥 검출에 관한 임상연구)

  • Lee Si-Woo;Lee Yu-Jung;Lee Hae-Jung;Kang Hee-Jung;Kim Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1673-1675
    • /
    • 2005
  • The pulse diagnosis is an important and universal method in Oriental medicine. Nevertheless, because of characteristic that depends on subjective sense of Oriental medicine doctor (OMD), it is not recognized by objective basis. The Korean Institute of Oriental Medicine(KIOM) and Daeyo Medi. Co. Ltd. developed the 3-D Mac using arrey piezoresistive sensors and multi-axial robot. 133 healthy subjects participated in this study, 75 males and 58 females, between 20 and 70 years of age. All subjects were relaxed in a supine position on a comfortable chair for twenty minutes before the measurement was taken. The measured position is the radial artery of subject's left wrist and the position is called Chon, Kwan and Chuck in Oriental medicine. To detect floating and sinking pulse, we established coefficient of floating and sinking(CFS). CFS means relative position of maximum pulse pressure in PH curve. The lower CFS value means that the pulse has floating tendency. There was significant diffence between CFS and diagnosis of floating-sinking pulse by OMD(p=0.020). CFS value of over 40's group was significantly larger than those of 20's and 30's(p=0.000). There was no significant difference between male and female(p=0.061).

Analysis of Deformation of Brass Tube Drawn By Various Methods (인발 방법에 따른 황동관의 변형 해석)

  • ;Oh Kyu Hwan;Lee Dong Nyung
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1995.10a
    • /
    • pp.76-85
    • /
    • 1995
  • The general equation of homogeneous strin for tube drawing has been derived. This can be applied to the general tube drawing method for non-zero plug angle. Also, the derived equation can represent Blazynski's equations for the sinking and tube drawing with a constant plug diameter. The general tube drawing was divided into two steps, sinking and contact drawing zones. The derived equation can calculate the homogeneous strains of the two steps. The various tube drawing methods such as fixed tapered plug, fixed mandrel, fixed back tapered plug, and floating plug have been analysed by the equation and finite element analysis. From the FEM calculations, the total strains and drawing stresses are obtained and consequently the redundancy factor of various drawing methods was analysed. The fixed back tapered plug method showed the largest redundancy factor and the floating plug method had the largest drawing stress.

  • PDF

Comparative Study of Qi-sensational Movement of 'Hanalmomjit' and the Properties of Materia Medica ('한알몸짓'의 기감동작(氣感動作)과 한약의 약성(藥性)에 대한 비교 연구)

  • Lee, Jeong-Won;Shin, Soon-Shik;Kim, Gyeong-Cheol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.358-362
    • /
    • 2005
  • Directional words like 'ascending(升, sheng)', 'descending(降, jiang)', 'floating(浮, fu)', 'sinking(沈, chen) are technical terminologies of Oriental Medicine to express the directions of material medica functioning-at the phase of Qi-superiorly, inferiorly, exteriorly, and interiorly in human body, and are constituting one of the major principles in prescribing medicines. Lacking the objective methodology to measure or, at least determine Qi, However, we can not expect to secure meaningful data to verify those directional terms. This problematic situation caused chaotic discrepancy between theory and practice of Oriental Medicine. Thus, adopting the method of dynamic meditation 'Hanalmomjit' of Lux Vitae meditation society, by which various state of Qi-sensational movements can be expressed, we compared its moves with the directional terms of traditional canons in Oriental Medicine. In this thesis, the experiment of expressing materia medica via 'Hanalmomjit' is resulted out and compared with the terms, confirmed to have a certain meaningfulness. The new method showed these results below: Herba Menthae, described to have the disposition of ascending and floating, showed 60% of ascending movements in 'Hanalmomjit' experiment. Radix Rehmanniae Praeparata, described to have the disposition of descending and sinking, showed 50% of descending movements. Radix Glycyrrhizae, described to have plain disposition, showed 60% of central movements. Rhizoma Atractylodis and Pericarpium Citri Reticulatae, described to have the disposition of ascending and floating, showed also ascending movements. Cortex Magnoliae Officinalis, described to have the disposition of descending and sinking, showed also descending movements. In conclusion, qi-sensational movement of 'Hanalmomjit' for materia medica showed sufficient relations described in classics, proving itself to be useful method for objective demonstration of material medica.

A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels (5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구)

  • Kown, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

Teachers' Perceptions of Explanatory Method Based-on Process Viewpoint for Floating and Sinking Phenomena (뜨고 가라앉는 현상에 대한 과정적 관점 설명방식에 대한 교사들의 인식)

  • Kim, Sungki;Paik, Seoung-Hye
    • Journal of The Korean Association For Science Education
    • /
    • v.40 no.6
    • /
    • pp.583-594
    • /
    • 2020
  • In this study, the existing concept of density has a limitation in providing the cause of phenomena, and the concept of buoyancy poses a problem because it has many misconceptions and requires an overly difficult concept to understand quantitative calculation, so we suggest an explaining method as process viewpoint introducing the principle of lever. The new method of explanation has been proposed using the lever as visual tool to reveal the gravity as the fundamental principle and process viewpoint. As a result, teachers stayed on many alternative concepts and less than half of the teachers were aware that density was related to gravity. In addition, they recognized it as matter viewpoints, but there is a meaningful conceptual change after intervention(p<.000). Also, they evaluated that the new method is better able to recognize the principle and process viewpoint than the existing description method. Through this, we can confirm the educational value of explaining method as process viewpoint introducing the principle of lever.

A Study of Structural Stability of HDPE Pipe during Installation (고밀도 폴리에틸렌 파이프의 설치중 구조안정성에 대한 연구)

  • Song, Hyun-Bae;Kim, Do-Kyun;Choi, Han-Suk;Park, Kyu-Sik
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.59-66
    • /
    • 2015
  • In this study, structural stability of large diameter high density polyethylene (HDPE) pipe during installation was numerically investigated in order to investigate the effect of concrete collar dimension, water depth and tension (pulling force). From the numerical simulation results, the total stress of HDPE pipe with designed concrete collar was within 2.5%, so the total weight of concrete collar for sinking of HDPE is important rather than concrete collar dimension. Furthermore, the tension area for possible installation is decreased as the air filling rate is increased. Therefore, it is important to calculate the reasonable tension range before actual installation for safe installation of HDPE pipe.