• Title/Summary/Keyword: flicker

Search Result 310, Processing Time 0.024 seconds

Parallel Coding Scheme for Flicker Mitigation in MIMO-VLC (다중입출력 가시광통신에서 플리커 현상을 완화하기 위한 병렬 코딩 기법)

  • Jeong, Jin-uk;Lee, Kye-san;Seo, Hyo-duck;Han, Doo-hee;Lee, Kyu-jin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.3
    • /
    • pp.146-154
    • /
    • 2016
  • Visible light communication using LED is a technique for transmitting digital data using the light of the LED. Recently, high-speed data rate plays an important role. Therefore, many scholars have researched the MIMO-VLC which is able to increase data rate using a lot of LED transmitters. However, it has problems such as light interference and flicker when transmitting different bit. Many researcher have focused on reduce interference. However it is not considered about flicker problem. Flicker is defined unstable brightness. It occurred the tired of human eyes, lowers eyesight and also decreases concentration. In order to solve this flicker problem in MIMO-VLC, we propose the PFM(Parallel Flicker Mitigation) code. PFM code using combinatorial theory can maintain constant brightness the whole bit duration. Therefore, it is possible to assure the brightness by confirm simulation results.

2MVA SSFG(Sag Swell Flicker Generator) Development for Actual Test of Custom Power Device (전력품질 향상기기의 실증시험을 위한 2MVA SSFG(Sag Swell Flicker Generator) 개발)

  • Kim H.J.;Chung Y.H.;Kwon G.H.;Park T.B.;Moon J.I.;Jeon Y.S.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.626-633
    • /
    • 2005
  • This paper proposes a new 2MVA SSFG(Sag Swell Flicker Generator) injecting voltage by using series inverter. The proposed SSFG composes series inverter, DC capacitor as energy storage, rectifier and voltage clamp circuit. This SSFG is designed to generate typical power disturbances, such as voltage sag/swell, over/under voltage and voltage flicker. Also it is designed to generate unexpected voltage phase jumping waveform by controlling the series inverter. In this paper, three kinds of control methods for the proposed 2MVA SSFG we investigated by PSIM simulation. Also typical voltage sag, swell, flicker waveforms are implemented by adopting effective control method.

A Low-Cost Digital PWM-Controlled LED Driver with PFC and Low Light Flicker

  • Li, Yi;Lim, Jae-Woo;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2334-2342
    • /
    • 2015
  • This paper proposes an LED driving circuit with a digital controller, power factor correct (PFC) function, and low light flicker. The key topology of the proposed circuit is a conventional Flyback combined with a pre-stage. As a result, there will be less light flicker than with other one-stage PFC circuits. A digital controller, implemented using a low-cost microcontroller, dsPIC30F2020, will meet PFC and low light flicker. The experimental results validate the functionality of the proposed circuit.

Flicker-Free Visible Light Communication System Using Byte-Inverted Transmission (바이트반전 전송방식을 이용한 플리커 방지 가시광통신시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.408-413
    • /
    • 2017
  • In this paper, we newly developed a byte-inverted transmission method for flicker-free visible light communication (VLC). The VLC transmitter sends original data in the former half period of the clock, and inverted data and in the latter half period of the clock. The VLC receiver receives the original data in the in the former half period of the clock. In this system, we used 480Hz clock that was generated from the 60Hz power line. The average optical power of the LED array in the transmitter is constant, thus flicker-free, in the observation time longer than the period of the clock that is about 2ms. This period is shorter than the maximum flickering time period (MFTP) of 5ms that is generally considered to be safe. This configuration is very useful in constructing indoor wireless sensor networks using LED light because it is flicker-free and does not require additional transmission channel for clock transmission.

Comparison of Various Methods to Mitigate the Flicker Level of DFIG in Considering the Effect of Grid Conditions

  • Kim, Yun-Seong;Marathe, Aditya;Won, Dong-Jun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.612-622
    • /
    • 2009
  • The short circuit ratio (SCR) of a given grid is able to show the stability of the system in the case of unwanted elements, such as wind turbulence. This paper presents the simulation of a model of the doubly fed induction generator in the simulation software PSCAD/EMTDC. This model has been used to study flicker during continuous operation and the effect of SCR and grid impedance angle on flicker emission. Simulation results show that compensation of the stator reactive power is an effective method to considerably reduce the flicker levels, irrespective of the grid conditions.

A Study on the Condition of LED Lights Flicker (국내 LED 조명등에서 플리커 현상에 관한 연구)

  • Heo, Min;Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.11
    • /
    • pp.729-735
    • /
    • 2016
  • It is highly important issue to use an energy efficiently for sustainable prosperity of mankind. From this point of view, using LED lighting can be a good alternative because it has a lot of advantages such as high efficiency, long life time and eco-friendly manufacturing process. That is the reason why using LED lighting has been encouraged worldwide. However, in situations that LED lighting is replacing traditional lighting quickly, the problem of the flicker of LED lighting has emerged as an important issue. Therefore, in foreign countries like US or Japan in order to ensure the reliability of LED lighting, study for flickering effects of the human body and test methods are have been actively conducted. But related research in domestic situation is an insufficient condition. In this study, a flicker characteristic was measured conventional lamps such as incandescent lamps or fluorescent lamp and 81 items of LED lightings which are distributed in domestic markets.

Analysis of Flicker Mitigation Effects using IEC Digital Flickermeter based on Matlab/Simulink Simulation (Matlab/Simulink 기반의 IEC 플리커미터를 이용한 플리커 저감효과 모의에 대한 연구)

  • Jung, Jae-Ahn;Cho, Soo-Hwan;Kwon, Sae-Hyuk;Jang, Gil-Soo;Kang, Moon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.232-238
    • /
    • 2009
  • Flicker, also known as voltage fluctuation, is a newest problem of power quality issues, because it is caused by nonlinear loads such as electrical arc furnace and large-scale induction motor, which are country-widely used as the heavy industries of a country develop. An international standard, International Electrotechnical Commission (IEC) 61000-4-15, was published in 1997 and revised in 2003. With increasing concerns about flicker, its mitigation methods have been also studied. General countermeasures for flicker are divided into three categories: a) enhancing the capacity of supplying system, b) Series elements including series reactor and series capacitor and c) power electronic devices including static VAR compensator (SVC) and static synchronous compensator (STATCOM). This paper introduces how to mitigate the voltage flicker at the point of common coupling (PCC) and presents how to simulate and compare the flicker alleviating effects by each mitigation method, using IEC flickermeter based on the Matlab/Simulink program.

Spectral Analysis of Flickering Effects in Binary Dimmable Visible Light Communication (조명의 디밍을 지원하는 이진 가시광 통신에 대한 플리커의 주파수 분석)

  • Lee, Sang Hyun;Kwon, Jae Kyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.240-245
    • /
    • 2015
  • This paper presents an impact of flicker for various binary modulations of visible light communication (VLC) under dimming requirement. While previous approaches consider the statistics of the signal that cannot capture contributions of dynamic impacts of flicker, the power spectral density is evaluated for various VLC transmission schemes of dimming support. This enables to compare transmission schemes with the contribution of low and intermediate frequency components to flicker. Numerical results show that analog dimming has advantages over other techniques in terms of flicker and signal processing with waveforms and symbol distribution allows to mitigate flicker effects.

Flicker Reduction Algorithm using Gamma Correction Parameter (감마보정 요소를 이용한 동영상 플리커 제거 알고리즘)

  • Choi, Heon-Hoi;Lee, Im-Geun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.397-400
    • /
    • 2010
  • The changing light condition of scene cause the luminance fluctuation of the captured image sequences. this artifact is called flicker, and would be easily recognized as visually unstable fluctuation. As the flicker degrades the performance of extracting useful information from image sequences, such as motion information or segmentation, it should be correction and linear flicker model. The algorithm model the flicker effects as a linear system with gain and offset parameter and estimates gain parameter with Gamma correction. The flicker reduction is performed by applying these parameters inversely th the ordinal sequences. To show the performance, we test out algorithm th the ground-truth sequences with the artificially added luminance fluctuation and real sequence with object motion.

  • PDF

Improvement in Computation of Δ V10 Flicker Severity Index Using Intelligent Methods

  • Moallem, Payman;Zargari, Abolfazl;Kiyoumarsi, Arash
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.228-236
    • /
    • 2011
  • The ${\Delta}\;V_{10}$ or 10-Hz flicker index, as a common method of measurement of voltage flicker severity in power systems, requires a high computational cost and a large amount of memory. In this paper, for measuring the ${\Delta}\;V_{10}$ index, a new method based on the Adaline (adaptive linear neuron) system, the FFT (fast Fourier transform), and the PSO (particle swarm optimization) algorithm is proposed. In this method, for reducing the sampling frequency, calculations are carried out on the envelope of a power system voltage that contains a flicker component. Extracting the envelope of the voltage is implemented by the Adaline system. In addition, in order to increase the accuracy in computing the flicker components, the PSO algorithm is used for reducing the spectral leakage error in the FFT calculations. Therefore, the proposed method has a lower computational cost in FFT computation due to the use of a smaller sampling window. It also requires less memory since it uses the envelope of the power system voltage. Moreover, it shows more accuracy because the PSO algorithm is used in the determination of the flicker frequency and the corresponding amplitude. The sensitivity of the proposed method with respect to the main frequency drift is very low. The proposed algorithm is evaluated by simulations. The validity of the simulations is proven by the implementation of the algorithm with an ARM microcontroller-based digital system. Finally, its function is evaluated with real-time measurements.