• 제목/요약/키워드: flexural failure

검색결과 862건 처리시간 0.03초

프리캐스트 콘크리트 교각의 구조거동에 관한 실험적 연구 (An Experimental Study for the Structural Behavior of the Precast Prestressed Concrete Columns)

  • 최승원;신현목;이재훈;오병환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.146-149
    • /
    • 2006
  • In many previous studies, a prestressed concrete column has a larger flexural strength, shear strength and restoring force than a RC column. Recently, a precast prestressed concrete column is rising up a very rational column structure in that a economic aspect. In a precast prestressed concrete column, it makes in a factory. So, it needs a small construction site and acquires a higher durability than a cast in place concrete column. Seven precast concrete columns were tested under a constant axial load and a cyclically reversed horizontal load to investigate the performance. It is designed with a hollow section and consisted of 4 segments. The main variables of the test were a amount of prestressed, a type of joints and a boding type of strands. The test results show that the performance of a precast prestressed concrete column; failure mode, maximum load, energy dissipation and stiffness degradation.

  • PDF

Simplification of the Flexural Capacity of SFR-UHPCC Rectangular Beam

  • 오향국;한상묵;김성욱;강수태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.526-529
    • /
    • 2006
  • In this paper, flexure behavior of steel fiber reinforcement ultra high performance cementations composites (SFR-UHPCC) has been analyzed by equivalent stress block. Pulling-out tensile force of steel fiber with concrete matrix was induced. An appropriate flexure evaluation formula, i.e. semi-analytical formula, was established based on rectangular cross section beam for comparing with shear capacity and ultimate load of SFR-UHPCC beam. Finally, the semi-analytical formula has been simplified for the convenience of design work. Experimental results and theoretical shear strength are shown to compare with the formula proposed by this paper. The theory formula has a good prediction of failure type of SFR-UHPCC.

  • PDF

저형상비 RC교각의 실물모형 준정적실험 (Quasi Static Test of Real Scaled RC Piers with Low-Aspect Ratio)

  • 조창백;곽임종;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.218-221
    • /
    • 2006
  • The past Korean Bridge Design Specifications have no limitation on the amount of lap splices of longitudinal bars in the plastic hinge zone of piers. A majority of bridge piers which have been non-seismically designed might have some lap splices in plastic hinge zone. Also a number of those piers in Korea have a low aspect ratio(height/section area). So, some problems such as low ductility behavior may happen. In this study, the real pier which was non-seismically designed and has a low aspect ratio was selected for the quasi-static tests. Two groups of full scaled RC pier models of which aspect ratios are about 2.26 and about 2.67 were fabricated. And then, quasi-static tests according to the drift level history method were implemented. From the test results, the failure of these test specimens have been shown in the complex shear-flexural or shear modes. The low aspect ratio and the lap splice have largely influenced on the seismic performance of bridge piers.

  • PDF

Ductility Assesment of Damaged RC Bridge Piers w with Lap-Spliced Bars

  • Chung, Young-Soo;Park, Chang-Kyu;Lee, Eun-Hee
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.453-456
    • /
    • 2003
  • This research is to evaluate the seismic performance of reinforced concrete bridge piers with lap-spliced longitudinal reinforcement steels in the plastic hinge region, and to develop the enhancement scheme of their seismic capacity. Six circular columns of 0.6m diameter and 1.5m height were made with two confinement steel ratios. They were damaged under series of artificial earthquakes that could be compatible in Korean peninsula. Directly after the pseudo-dynamic test, damaged columns were retested under inelastic reversal cyclic loading simultaneously under an axial load, P=$0.1f_{ck}A_{g}$, and residual seismic performance of damaged columns was evaluated. Test results show that RC bridge piers with lap-spliced longitudinal steels behaved with minor damage even under artificial earthquakes with 0.22g PGA, but failed at low ductility subjected to the subsequent quasi-static load test. This failure was due to the debonding of the lap splice. The specimens externally wrapped with composite FRP straps in the potential plastic hinge region showed significant improvement both in flexural strength and displacement ductility.

  • PDF

화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 구조 거동 (Structural Behavior of Fire-Damaged Reinforced Concrete Beam with High Strength Concrete)

  • 신미경;신영수;이차돈;홍성걸;이은주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.635-638
    • /
    • 2003
  • This paper deals with structural behavior of reinforced concrete beams with high strength under fire and fire damaged condition. The main purpose of this study is to evaluate the residual strength of flexural members by exposure time to fire. For this purpose, six beam specimens are fabricated and experimented. Among the specimens, four specimens are exposed to the fire for 60 and 90 minutes and two specimens are control beam that is not exposed to fire. After being cooled in room temperature, the specimens are loaded to the failure. The research result shows that the main variables of the test, concrete cover and exposure time to fire are much influenced on the structural behavior and the residual strength.

  • PDF

비선형요구내력스펙트럼을 이용한 철근콘크리트건물의 지진손상도 평가법 - Part I. 지진손상도 평가법 개념 - (A New Methodology of Earthquake Damage Evaluation for R/C Buildings Based on Non-linear Required Strength Spectrum - Part I. Concept of Earthquake Damage Evaluation -)

  • 이강석;위정두;전경주;최윤철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.111-112
    • /
    • 2010
  • 본 연구에서는 비선형 지진응답해석을 이용하여 유도된 전단 및 휨파괴형 부재가 혼합된 철근콘크리트 건물의 비선형 요구내력스펙트럼을 이용한 지진손상도 평가법을 제안하였다. Part I에서는 지진 손상도 평가법, 즉 비선형 요구내력스펙트럼을 수식화하여 대상건물의 특정 연성률별로 지진입력수준과 내진성능잔존률(R)을 산정하여 구조물의 손상정도를 평가하는 지진손상도 평가법의 개념을 나타낸다.

  • PDF

반응소결법에 의한 SiC/SiC 복합재료의 제조 (Fabrication of SiC/SiC Composites by Reaction Sintering Process)

  • 이상필;윤한기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.27-31
    • /
    • 2001
  • Hi-Nicalon SiC fiber reinforced SiC composites (SiC/SiC) have been fabricated by the reaction sintering process. Braided Hi-Nicalon SiC fiber with double interphases of BN and SiC was used in this composite system. The microstructures and the mechanical properties of reaction sintered SiC/SiC composites were investigated through means of electron microscopies (SEM, TEM, EDS) and bending tests. The matrix morphology of reaction sintered SiC/SiC composites was composed of the SiC phases that the composition of the silicon and the carbon is different. The TEM analysis showed that the residual silicon and the unreacted carbon were finely distributed in the matrix region of reaction sintered SiC/SiC composites. Reaction sintered SiC/SiC composites also represented proper flexural strength and fracture energy, accompanying the noncatastrophic failure behavior.

  • PDF

Finite element modeling of tubular truss bearings

  • Kozy, B.;Earls, C.J.
    • Steel and Composite Structures
    • /
    • 제5권1호
    • /
    • pp.49-70
    • /
    • 2005
  • This paper reports on finite element analysis techniques that may be applied to the study of circular hollow structural sections and related bearing connection geometries. Specifically, a connection detail involving curved steel saddle bearings and a Structural Tee (ST) connected directly to a large-diameter Hollow Structural Section (HSS) truss chord, near its open end, is considered. The modeling is carried out using experimentally verified techniques. It is determined that the primary mechanism of failure involves a flexural collapse of the HSS chord through plastification of the chord wall into a well-defined yield line mechanism; a limit state for which a shell-based finite element model is well-suited to capture. It is also found that classical metal plasticity material models may be somewhat limited in their applicability to steels in fabricated tubular members.

철근콘크리트보의 휨내력보강 공법에 관한 실험적 연구 (An Experimental Study on the Rehabilitation Technics of R/C Flexural Member)

  • 김성철;이희경;유성훈;김중구;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.715-720
    • /
    • 1997
  • In this study, the behavior of R/C beam strengthened with carbon fiber laminate(C.F.L) is analyzed from the test results. Test parameters ar the width and the thickness of C.F.L. The failure mode and ultimate load are analyzed from these measured data. Test results shows that the peak load of specimens strengthened with C.F.L. is increased to 1.27~2.04 times of that of non-rehabilitation specimen. The wider lap width, large amount of rehabilitation materials, the larger strength is obtained.

  • PDF

콘크리트 파괴거동특성에 대한 실험적 연구II-직접인장시험 (Experimental Study on Failure Behavior of Plain Concrete - Direct Tension Test)

  • 이상근;이상민;이화미;한상훈;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.287-292
    • /
    • 2003
  • The large-scale direct tension tests of plain concrete were performed and then the complete load-CMOD(crack mouth opening displacement) curves with a stable postpeak descending part were presented. Two independently controlled actuators were used to ensure a homogeneous increasing of CMOD in both notches of a specimen and to avoid secondary flexural stresses. It was compared the fracture energies from the test results with them from a classical prediction equation by Bazant and Oh (983), The results are indicated that the fracture energies from these large-scale direct tensile tests are large as 1.5-2 times on average against them from the Bazants prediction equation. But the tensile strength for large-size specimens was about half of the values determined from the splitting tensile strength tests for 10 by 20mm cylindrical specimens due to size effect.

  • PDF