• Title/Summary/Keyword: flexural failure

Search Result 859, Processing Time 0.025 seconds

Analysis of Slender RC Short Beams(a/d<2.5) with Vertical Stirrups using Nonlinear FEM (비선형유한요소해석을 이용한 수직 스터럽이 있는 RC 짧은 보의 해석)

  • Jeong, Jae-Pyong;Kim, Dae-Joong;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.259-264
    • /
    • 2002
  • This paper describes an attempt to develop a unified design approach for reinforced concrete short beam failing in shear based on a Arch Factor. Designing for short beam in shear is not as straightforward as designing for flexure due to the complicated interdependency of the variables involved and to the nonexistence of a rational theory tn current design code. Shear failure of reinforced concrete beams with stirrups is influenced greatly because of the actual geometrical shape(a/d) of the concrete and flexural reinforcement steel ratio, stirrup reinforcement ratio and concrete compression strength, size effect etc. The objective of this paper is to present a pilot study to develop a simplified physical model for estimating shear behavior of reinforced concrete short beams. The Key idea incorporated with this model is the Arch factor, introduced by Kim and White.

  • PDF

The Shear-Properties of Reinforced Concrete Beams without Web Reinforcement (복부보강이 없는 철근콘크리트보의 전단특성)

  • 문제길;홍익표
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.151-161
    • /
    • 1993
  • 본 논문은 전단철근을 갖지 않는 비교적 짧은 지간의 철근콘크리트 보에서 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 총30개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 전단지간-유효높이의 비, 인장철근량등이며, 실험과정을 통해 파괴형상, 처짐, 전단강도등을 측정하였다. 실험결과로부터 콘크리트의 강도가 커지고 철근량이 많아질수록, 그리고 전단지간이 짧아질수록 철근콘크리트 보의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험성과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안하였다. 제안된 추정식에 의한 계산값과 실험성과를 비교 검토하여 그 상관성을 확인하였다.

Behavior of SFRC interior beam-column joints under cyclic loading

  • Khalaf, Noor Ayaad;Qissab, Musab Aied
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.3
    • /
    • pp.167-193
    • /
    • 2020
  • In this paper, the behavior of interior steel fiber reinforced concrete beam - column joints (BCJs) under cyclic loading is investigated. An experimental program including tests on twelve reinforced concrete (BCJs) specimens under cyclic loading was carried out. The test specimens are divided into two groups having different geometry: group (G1) (symmetrical BCJs specimens) and group (G2) (nonsymmetrical BCJs specimens). The parameters considered in this study are the steel fibers (SFs) content by volume of concrete (Vf), the spacing of shear reinforcement at the joint region, and the area of longitudinal flexural reinforcement. Test results show that the addition of 0.5% SFs with stirrups spacing S=Smax has effectively enhanced the overall performance of BCJs with respect to energy dissipation, ductility ratio, spreading and width of cracks. The failure of specimens is governed mainly by the formation of a plastic hinge at the face column and outside the beam-column junction. Secondary shear cracks were also observed in the beam-column junctions.

Tests of concrete slabs reinforced with CFRP prestressed prisms

  • Liang, Jiongfeng;Yu, Deng;Yang, Zeping;Chai, Xinjun
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.355-366
    • /
    • 2016
  • This paper reports the testing of concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) on the flexural behavior. Four concrete slabs were tested, a reference slab reinforced with steel bars, and three slabs reinforced with CFRP prestressed concrete prisms (PCP). All slabs were made with dimensions of 600mm in width, 2200mm in length and 150 in depth. All concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) exhibited CFRP bar rupture failure mode. It was shown that the application of the CFRP prestressed prisms can limit service load deflections and crack width, the increased level of prestress in the CFRP prestressed prism positively affected the maximum crack width. The deflection of concrete slabs reinforced with CFRP prestressed prisms decreased as prestress in the CFRP prestressed prism increased.

Application of fiber element in the assessment of the cyclic loading behavior of RC columns

  • Sadjadi, R.;Kianoush, M.R.
    • Structural Engineering and Mechanics
    • /
    • v.34 no.3
    • /
    • pp.301-317
    • /
    • 2010
  • This paper studies the reliability of an analytical tool for predicting the lateral load-deformation response of RC columns while subjected to lateral cyclic displacements and axial load. The analytical tool in this study is based on a fiber element model implemented into the program DRAIN-2DX (fiber element). The response of RC column under cyclic displacement is defined by the behavior of concrete, and reinforcing steel under general reversed-cyclic loading. A tri-linear stress-strain relationship for the cyclic behavior of steel is proposed and the improvement in the analytical results is studied. This study only considers the behavior of columns with flexural dominant mode of failure. It is concluded that with the implementation of appropriate constitutive material models, the described analytical tools can predict the response of the columns with reasonable accuracy when compared to experimental data.

Centrifuge modelling of temporary roadway systems subject to rolling type loading

  • Lees, Andrew S.;Richards, David J.
    • Geomechanics and Engineering
    • /
    • v.3 no.1
    • /
    • pp.45-59
    • /
    • 2011
  • Scaled centrifuge modelling techniques were used to study the soil-structure interactions and performance of a jointed rollable aluminium roadway (or trackway) system on soft clay under light truck tyre loads. The measured performance and subsequent analyses highlighted that the articulated connections significantly reduced the overall longitudinal flexural stiffness of the roadway leading to stress concentrations in the soil below the joints under tyred vehicle loadings. This resulted in rapid localised failure of the supporting soil that in turn led to excessive transverse flexure of the roadway and ultimately plastic deformations. It is shown that the performance of rollable roadway systems under tyred vehicle trafficking will be improved by eliminating joint rotation to increase longitudinal stiffness.

Transfer Bond test on Domestic Sevenwire Prestressing Strands (국내산 7연강선의 트렌스퍼 정착부착 실험)

  • 김승욱;김대훈;유재천;유승룡
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.387-392
    • /
    • 1999
  • The bond performance of prestressing strands is still not well understood and is still in controversy on the validity of the test results up to today, although it is a basic information to desing the prestressed pretensioned concrete beams. Different transfer length has been found for a product of the same company, but of the different production methods and factories in the United States. It is necessary to determine optimum transfer bond length of the domestic stands because the ultimate flexural and shear capacity in a section of prestressed concrete beams are evaluated under the assumption that the anchorage bond failure shall not happen. The transfer lenght of low-relaxation, Gr 270, and 1/2" seven-wire prestressing strands from four domestic companies will be evaluated by the concrete strain method. The recent concept of the 95% Maximum Average Strain Method suggested by Russel et al. will be considered to obtain the transfer length of domestic strands. It will be also evaluated if the domestic strands are conform to ACI 318-95.8-95.

  • PDF

Development of Flexural Capacity of RC Beam by CFRP Strengthening Methods (CFRP 보강공법에 따른 RC보의 휨성능 개선효과)

  • Hong Ki Nam;Han Sang Hoon;Kim Hyung Soo;Woo Sang Kyun;Song Young chul;Kim Hyung Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.133-136
    • /
    • 2005
  • Experimental research was conducted to investigate the characteristic of various CFRP strengthening methods. A total of 4 specimens of 3.3m length were tested in four point bending after strengthening them with externally bonded CFRP plates. The CFRP plates were bonded without prestress or with prestress levels of CFRP plate strain $0.5\%$. The non-prestressed specimen without anchor plate failed by separation of the plate from the beam due to premature debonding while the non-prestressed specimen with anchor plate failed by CFRP fracture and showed the significant increase of ductility capacity. In addition, the prestressed specimens failed by concrete compression failure. The maximum load and ductility capacity were most significantly increased.

  • PDF

An Experimental Study for the Structural Behavior of the Precast Prestressed Concrete Columns (프리캐스트 콘크리트 교각의 구조거동에 관한 실험적 연구)

  • Choi, Seung-Won;Shin, Hyun-Mok;Lee, Jae-Hoon;Oh, Byung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.146-149
    • /
    • 2006
  • In many previous studies, a prestressed concrete column has a larger flexural strength, shear strength and restoring force than a RC column. Recently, a precast prestressed concrete column is rising up a very rational column structure in that a economic aspect. In a precast prestressed concrete column, it makes in a factory. So, it needs a small construction site and acquires a higher durability than a cast in place concrete column. Seven precast concrete columns were tested under a constant axial load and a cyclically reversed horizontal load to investigate the performance. It is designed with a hollow section and consisted of 4 segments. The main variables of the test were a amount of prestressed, a type of joints and a boding type of strands. The test results show that the performance of a precast prestressed concrete column; failure mode, maximum load, energy dissipation and stiffness degradation.

  • PDF

Simplification of the Flexural Capacity of SFR-UHPCC Rectangular Beam

  • Han, Sang-Mook;Wu, Xiang-Guo;Kim, Sung-Wook;Kang, Su-Tae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.526-529
    • /
    • 2006
  • In this paper, flexure behavior of steel fiber reinforcement ultra high performance cementations composites (SFR-UHPCC) has been analyzed by equivalent stress block. Pulling-out tensile force of steel fiber with concrete matrix was induced. An appropriate flexure evaluation formula, i.e. semi-analytical formula, was established based on rectangular cross section beam for comparing with shear capacity and ultimate load of SFR-UHPCC beam. Finally, the semi-analytical formula has been simplified for the convenience of design work. Experimental results and theoretical shear strength are shown to compare with the formula proposed by this paper. The theory formula has a good prediction of failure type of SFR-UHPCC.

  • PDF