• 제목/요약/키워드: flexural behavior of composite beam

검색결과 167건 처리시간 0.029초

기둥 주위에 슬리트를 갖는 합성보 접합부의 반복하중 하에서의 거동 (Hysteretic Behavior of Composite Beam Detail with Slit around Column)

  • 양일승;윤현도;이강민;박완신;한병찬;문연준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.101-104
    • /
    • 2004
  • Composite beams are generally known to possess higher flexural stiffness and strength under the positive bending moments than the normal steel beams. However the these beams also exhibit large differences in flexural stiffness and strength when both positive and negative bending moments are applied. As observed during the 1995 Kobe Earthquake, these beams tend to be fractured on the bottom flanges under repeated cyclic loadings. The objective of this study is to develop and evaluate the composite beam detail, which is able to effectively resist the seismic loadings. The proposed system is composed of the slit on concrete slab around column. A limited experimental program was designed and conducted to investigate the hysteretic behavior of the proposed composite beam system. From the experimental data obtained from the testing of three specimens, the proposed composite beam detail is found to possess large beam rotation than normal steel beams.

  • PDF

Flexural stiffness of steel-concrete composite beam under positive moment

  • Ding, Fa-Xing;Liu, Jing;Liu, Xue-Mei;Guo, Feng-Qi;Jiang, Li-Zhong
    • Steel and Composite Structures
    • /
    • 제20권6호
    • /
    • pp.1369-1389
    • /
    • 2016
  • This paper investigates the flexural stiffness of simply supported steel-concrete composite I-beams under positive bending moment through combined experimental, numerical, and different standard methods. 14 composite beams are tested for experimental study and parameters including shear connection degree, transverse and longitudinal reinforcement ratios, loading way are also investigated. ABAQUS is employed to establish finite element (FE) models to simulate the flexural behavior of composite beams. The influences of a few key parameters, such as the shear connection degree, stud arrangement, stud diameter, beam length, loading way, on the flexural stiffness is also studied by parametric study. In addition, three widely used standard methods including GB, AISC, and British standards are used to estimate the flexural stiffness of the composite beams. The results are compared with the experimental and numerical results. The findings have provided comprehensive understanding of the flexural stiffness and the modelling of the composite beams. The results also indicate that GB 50017-2003 could provide better results in comparison to the other standards.

Loading capacity of simply supported composite slim beam with deep deck

  • Shi, Yongjiu;Yang, Lu;Wang, Yuanqing;Li, Qiuzhe
    • Steel and Composite Structures
    • /
    • 제9권4호
    • /
    • pp.349-366
    • /
    • 2009
  • The composite slim beam has become popular throughout Europe in recent years and has also been used on some projects in China. With its steel section encased in a concrete slab, the steel-concrete composite slim beam can provide the floor construction with minimum depth and high fire resistance. However, the design method of the T-shape steel-concrete composite beam is no longer applicable to the composite slim beam with deep deck for its special construction, of which the present design models are not available but mainly depend on experiences. The elevation of the flexural stiffness and bending capacity of composite slim beams with deep deck is rather complicated, because the influences of many factors should be taken into account, such as the variable section dimensions, development of cracks and non-linear characteristics of concrete, etc. In this paper, experimental investigations have been conducted into the flexural behavior of two specimens of simply supported composite slim beam with deep deck. The emphases were laid on the bonding force on the interface between steel beam and concrete, the stress distribution of beam section, the flexural stiffness and bending capacity of the composite beams. Based on the experimental results, the reduction factor of equivalent stress distribution in concrete flange is suggested, and the calculation method of flexural stiffness and bending capacity of simply supported slim beams are proposed.

Experimental and analytical study on RC beam reinforced with SFCB of different fiber volume ratios under flexural loading

  • Lin, Jia-Xiang;Cai, Yong-Jian;Yang, Ze-Ming;Xiao, Shu-Hua;Chen, Zhan-Biao;Li, Li-Juan;Guo, Yong-Chang;Wei, Fei-Fei
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.133-145
    • /
    • 2022
  • Steel fiber composite bar (SFCB) is a novel type of reinforcement, which has good ductility and durability performance. Due to the unique pseudo strain hardening tensile behavior of SFCB, different flexural behavior is expected of SFCB reinforced concrete (SFCB-RC) beams from traditional steel bar reinforced concrete (S-RC) beams and FRP bar reinforced concrete (F-RC) beams. To investigate the flexural behavior of SFCB-RC beam, four points bending tests were carried out and different flexural behaviors between S/F/SFCB-RC beams were discussed. An flexural analytical model of SFCB-RC beams is proposed and proved by the current and existing experimental results. Based on the proposed model, the influence of the fiber volume ratio R of the SFCB on the flexural behavior of SFCB-RC beams is discussed. The results show that the proposed model is effective for all S/F/SFCB-RC flexural members. Fiber volume ratio R is a key parameter affecting the flexural behavior of SFCB-RC. By controlling the fiber volume ratio of SFCB reinforcements, the flexural behavior of the SFCB-RC flexural members such as bearing capacity, bending stiffness, ductility and repairability of SFCB-RC structures can be designed.

Flexural behavior of cold-formed steel concrete composite beams

  • Valsa Ipe, T.;Sharada Bai, H.;Manjula Vani, K.;Zafar Iqbal, Merchant Mohd
    • Steel and Composite Structures
    • /
    • 제14권2호
    • /
    • pp.105-120
    • /
    • 2013
  • Flexural behavior of thin walled steel-concrete composite sections as cross sections for beams is investigated by conducting an experimental study supported by applicable analytical predictions. The experimental study consists of testing up to failure, simply supported beams of effective span 1440 mm under two point loading. The test specimens consisted of composite box and channel (with lip placed on tension side and compression side) sections, the behavior of which was compared with companion empty sections. To understand the role of shear connectors in developing the composite action, some of the composite sections were provided with novel simple bar type and conventional bolt type shear connectors in the shear zone of beams. Two RCC beams having equivalent ultimate moment carrying capacities as that of composite channel and box sections were also considered in the study. The study showed that the strength to weight ratio of composite beams is much higher than RCC beams and ductility index is also more than RCC and empty beams. The analytical predictions were found to compare fairly well with the experimental results, thereby validating the applicability of rigid plastic theory to cold-formed steel concrete composite beams.

Flexural behavior and flexural capacity prediction of precast prestressed composite beams

  • Hu, Manxin;Yang, Yong;Yu, Yunlong;Xue, Yicong
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.225-238
    • /
    • 2022
  • In order to improve the cracking resistance of reinforced concrete and give full play to the advantages of prefabricated assembly structure in construction, prestressed reinforced concrete composite beam (PRCC) is proposed. Through the bending static test of seven I-shaped beam specimens, the bending failure modes and bearing capacity of PRCC and reinforced concrete composite beam are compared and analyzed, and the effects of prestress size, prestressed reinforcement layout and prestress application sequence on the flexural behavior of PRCC beams are studied. The results show that the cracking load and ultimate load of PRCC beams significantly increased after prestressing, and prestressed tendons can effectively control the crack development. With the increase of prestressing degree, the deformation resistance and bending stiffness of PRCC beams are increased. The application sequence of prestress has little influence on the mechanical properties of PRCC beams. The crack width, stiffness and normal section bearing capacity of PRCC beam are analyzed, and the calculated results are in good agreement with the experimental results.

완전매입형 복합트러스 합성보의 내하력 평가 (The Study on Ultimate Strength of Fully Embedded Composite Truss Beam)

  • 천성봉;원대연;최홍식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.306-309
    • /
    • 2006
  • The fully embedded composite truss beam is developed based on composite member, truss system before composite and beam system after composite. The proper design concept and method of the fully embedded composite truss beam are discussed. A bending test on the fully embedded composite truss beam with span length 25.0m is carried out to investigate the flexural behavior and ultimate strength of the developed structure up to failure. A good agreement between the measured and predicted results are observed.

  • PDF

U-플랜지 트러스 복합보의 휨 내력에 대한 실험 연구 (Experimental Study on the Flexural Capacity of the U-Flanged Truss Hybrid Beam)

  • 오명호;김영호;김명한
    • 한국공간구조학회논문집
    • /
    • 제18권4호
    • /
    • pp.123-130
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars welded on the upper and lower sides. The hybrid beam with U-flanged steel truss is made in the construction site through pouring the concrete, and designated as U-flanged truss hybrid beam. In this study the structural experiments on the 4 hybrid beams with the proposed basic shapes were performed, and the flexural capacities from the tests were compared with those from the theoretical approach. The failure modes of each specimen were quite similar. The peak load was reached with the ductile behavior after yielding, and the failure occurred through the concrete crushing. The considerable increasement of deformation was observed up to the concrete crushing. The composite action of concrete and steel member was considered to be reliable from the behavior of specimens. The flexural strength of hybrid beam has been evaluated exactly using the calculation method applied in the boubly reinforced concrete beam. The placement of additional rebars in the bottom instead of upper side is proposed for the efficient design of U-flanged truss hybrid beam.

상부플랜지를 감소시킨 합성보의 휨내력에 관한 실험적 연구 (An Experimental Study on Flexural Strength of Composite Beam with Reduced Top Flange of Steel)

  • 문찬일;정재훈;김진무;주경재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권3호
    • /
    • pp.153-160
    • /
    • 2000
  • In simply supported composite beams, the neutral axis of the composite cross section usually is located the top flange of the steel I-shape, so that the top flange does not impart much strength to the member. This suggests that omitting the top flange entirely could be a means to lower the cost of the beam without greatly reducing the strength. The purpose of this investigation is to research flexural strength and behavior of the composite beams with reduced top flange of steel. Five specimens with H and inverted T steel section were tested. As the test results, comparison of the experimental to computed full-plastic moment, and variations of flexural strength with reduced top flange were analyzed.

  • PDF

반슬림 폐단면 충전형 합성보의 휨성능 평가 (Bending Capacity Evaluation of the Infilled Composite Beam with Semi-slim Closed Section)

  • 임환택;최병정
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.130-140
    • /
    • 2018
  • U형 강재보를 근간으로 콘크리트 슬래브와 합성을 위하여 A형의 덮개형 강재앵커를 검토하여 AU합성보를 연구하였다. 이는 노출형의 H형강 강재보에 비해 내부 평면의 자율성을 높일 수 있고 공기 단축과 더불어 층고 절감이 가능하며 튜브구조로서 내부에 콘크리틀 충전하여 휨 강도과 휨 강성를 높였다. 본 연구에서는 AU합성보의 휨실험을 통해 성능을 평가하였다. 실험 결과, 하중 초기에 선형적으로 하중이 증가하면서 콘크리트 슬래브의 파괴에 의해 최대 강도에 도달하고 최대 내력의 85% 이상을 발휘하며 연성적 거동을 하였다. 또한, 덮개형 강재앵커를 통해 합성효과를 발휘하였으며 모든 실험체가 최대 내력에 도달할 때까지 완전 합성거동으로 안정적이었다. 그리고 U형 단면의 강판 두께를 증가시켰을 경우에도 휨 강도와 휨 강성이 증가하였고, U형 단면의 하부에 고강도 강판을 용접 부착하였을 경우에도 성능이 개선되었다. AU합성보의 휨강도는 건축구조기준에 따라 제안된 휨 강도식을 적용할 수 있을 것으로 판단되었다.