• Title/Summary/Keyword: flat-top

Search Result 241, Processing Time 0.022 seconds

A Study on Turbulence Stimulation Effect of Studs for Boundary Layer Over a Flat Plate (평판 경계층에 대한 스터드의 난류촉진 영향 연구)

  • Lee, Joon-Hyoung;Jeong, So-Won;Hwang, Seunghyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.1
    • /
    • pp.18-28
    • /
    • 2022
  • The turbulence stimulation effect of studs for boundary layer over a flat plate was investigated through the flow measurement in KRISO cavitation tunnel. For the test, Laser Doppler Velocimetry (LDV) and three flat plate models were used: (1) flat plate without studs; (2) flat plate with one stud row; (3) flat plate with two stud rows. The dimension and location of stud rows and the inflow speed were selected considering test conditions for standard-sized model ships in KRISO towing tank. The boundary layer characteristics of test models were analyzed and compared in terms of mean velocity profiles, turbulence intensity profiles, boundary layer thickness, and shape factor. In the case of the flat plate without studs, transition from laminar to turbulent flow occurred around Rex=3.83 ~ 5.19 × 105. In the case of flat plates with stud rows, the flow rapidly changed into turbulent flow right after passing the first stud row. In the state where turbulence was already developed, the second stud row slightly increased the turbulence intensity near the top of the stud, but did not significantly affect the boundary layer characteristics such as mean velocity distribution, boundary layer thickness, and shape factor.

KLYSTRON-MODULATOR SYSTEM PERFORMANCES FOR PLS 2-GeV LINAC (포항 20억 전자볼트 선형가속기 클라이스트론-모듈레이터 시스템의 성능)

  • Park, S.W.;Park, S.S.;Lee, K.T.;Oh, J.S.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1365-1367
    • /
    • 1995
  • The PLS 2-GeV linac employs 11 units of high-power pulsed klystrons(80MW) as the main RF sources. The matching modulators of 200 MW(400kV, 500 A) can provide a flat-top pulse width of 4.4 ${\mu}s$ with a maximum pulse repetition rate of 120 Hz at the full power level. For a good stability of electron beams, the pulse-to-pulse flat-top voltage variation of a modulator requires less than 0.5%. In order to achieve this goal, we stabilized high voltage charging power supplies within 1% by a phase controlled SCR voltage regulator. In addition, we employed ac/dc feedback together with a resistive De-Q'ing system to achieve far less than 0.5% variation of the PFN charging voltage. This paper presents the main feature of the klystron-modulator system and the characteristics of the pulsed high-power RF system performance during the beam injection operation for the Pohang Light Source commissioning.

  • PDF

Frictional Contact Model for Finite Element Analysis of Sheet-Metal Forming Processes (박판 성형 공정의 유한요소 해석을 위한 마찰접촉 모델)

  • 금영탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2242-2251
    • /
    • 1993
  • The mesh-based frictional contact model has been developed which does not rely on the spatial derivatives of the tool surface. Only points on the surface are evaluated from the description. which can then be simplified because of the relaxed demands placed on it. The surface tangents, normals, and corresponding derivatives at each finite-element node are evaluated directly from the finite-element mesh, in terms of the connecting nodal positions. The advantages accrue because there is no longer a need for a smooth tool surface to assure reasonable normals and derivatives. Furthermore, it can be shown that the equilibrium equations can only be properly written with a special normal derived from the mesh itself. The validity, accuracy, computation time, and stability of mesh-based contact model were discussed with the numerical examples of rounded flat-top and rough, flat-top rounded punch forming operations. Also, the forming process of a automobile inner panel section was simulated for testing the robustness of new contact model. In the discussion, the superiority of new model was examined, comparing with tool-based contact one.

Study on Analysis of Output Polarization of Lyot-Type High-Order Fiber Comb Filter Based on Polarization-Diversity Loop Structure (편광상이 고리 구조 기반 Lyot형 고차 광섬유 빗살 필터의 출력 편광 분석에 관한 연구)

  • Jo, Songhyun;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.17-24
    • /
    • 2015
  • In this paper, we investigated the output polarization of a Lyot-type optical fiber comb filter based on a polarization-diversity loop structure. It was found that the output state of polarization (SOP) of the filter made a wavelength-dependent evolution, and the spectral periods of the output SOP variation in flat-top and lossy flat-top band modes were the channel separation of the filter and its half, respectively. For a certain input SOP, the filter could pass or reject specific spectral sections by adding and controlling an output analyzer. In particular, it was theoretically anticipated that the filter with the output polarizer could provide the fine continuous tuning of its pass band center in a wavelength range corresponding to the ${\pm}9.5%$ of channel spacing(0.8nm) when the input SOP was properly adjusted. It is expected that this tuning function can be effectively applied to suppress unwanted spectral portions in modulated optical signals.

Research on BTU and Short-axis Geometry of Line-beam Optics for LLO Applications (레이저 박리용 선형 빔 광학계의 빔 변환 모듈과 단축 형상에 대한 연구)

  • Lee, Seungmin;Lee, Gwangjin;Kim, Daeyong;Lee, Sanghyun;Jung, Jinho
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.276-285
    • /
    • 2021
  • This paper reports the study of the line-beam optical system of the laser lift-off (LLO) equipment used in the OLED manufacturing process. To obtain both a long process depth and a narrow width of the line beam, even with the poor M2 value of the laser source, the research is focused on the optical system, including the beam transformation unit (BTU). We also propose optical configurations for the super-Gaussian distribution and the fiber-based BTU for the flat-top distribution.

Buckling conditions and strengthening by CFRP composite of cylindrical steel water tanks under seismic load

  • Ali Ihsan Celik;Mehmet Metin Kose;Ahmet Celal Apay
    • Earthquakes and Structures
    • /
    • v.27 no.2
    • /
    • pp.97-111
    • /
    • 2024
  • In this paper, buckling conditions and retrofitting of cylindrical steel water storage tanks with different roof types and wall thicknesses were investigated by using finite element method. Four roof types of cylindrical steel tanks which are open-top, flat-closed, conical-closed and torispherical-closed and three wall thicknesses of 4, 6 and 8 mm were considered in FE modeling of cylindrical steel tanks. The roof shapes significantly affect load distribution on the tank shell under the seismic action. Composite FRP materials are widely used for winding thin-walled cylindrical steel structures. The retrofitting efficiency of cylindrical steel water tank is tested under the seismic loading with the externally bonded CFRP laminates. In retrofitting of cylindrical steel tank, the CFRP composite material coating method was used to improve of seismic performance of cylindrical steel tanks. ANSYS software was used to analyze the cylindrical steel tanks and maximum equivalent (von-Mises) and directional deformation were obtained. Equivalent (von-Mises) stresses significantly decreased due to the coating of the tank shell with FRP composite material. In thin-walled steel structures, excessive stress causes buckling and deformations. Therefore, retrofitting led to decrease in stress, reductions in directional and buckling deformation of the open-top, flat-closed, conical-closed and torispherical-closed tanks.

In-Cylinder Flow Analysis in a Spark-ignited Direct Injection Engine using CFD (CFD를 이용한 직접 분사식 스파크 점화 엔진의 실린더 내부 유동 해석)

  • 김명환;이내현;최규훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.22-30
    • /
    • 1999
  • Optimization of in-cylinder flow is regarded as one of the most important factors to realize stable stratified charge combustion in a Spark-ignited Direct Injection(SDI) engine. Therefore, Computational Fluid Dynamic(CFD) simulation technique were used to clarify the characteristics of in-cylinder flow of a SDI engine with top entry intake port. Also, CFD results were compared to experimental results using Laser Doppler Velocimetry(LDV), Particle Image Velocimetry(PIV) and good validations were met. As the results reverse tumble flow generated during intake process was preserved by configuration of curved piston while base and reverse tumbles were diminished at the end of compression stroke in case of flat top piston. In addition, it will be needed to optimize the fuel mixture distribution based on these results.

  • PDF

Propagation Analysis of DGPS Antenna for Radial Ground and Obstacle

  • Kim, Young-Wan
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.4
    • /
    • pp.363-368
    • /
    • 2011
  • The DGPS transmits the enhancement signal to GPS using the medium frequency band. The NDGPS service that covers the Korean peninsula has been started since 2009. The service area of ocean-based DGPS(maritime-DGPS) reference stations covers the 100NM, but land-based DGPS(land-DGPS) covers 80km service area less than that of maritime DGPS. The DGPS's antenna has the top-loaded monopole antenna type. Top-loaded monopoles are the logical antennas to be used in order to get a low profile antenna and a performance according to the broadcaster and communication needs. The antenna needs to get the ground plane with good conductivity characteristics and flat ground plane without obstacle near to the transmitting antenna. In this paper, the radiation characteristics of an equivalent MF antenna are analyzed in view points of the ground conductivity and the ground plane with obstacle near to the antenna.

FLAT-FIELDING FOR SOLAR FULL DISK Hα MONITORING SYSTEM OF KASI (한국천문연구원 Hα 태양전면관측시스템의 바닥고르기 연구)

  • Park, H.M.;Kim, Y.H.;Bong, S.C.;Park, Y.D.;Cho, K.S.;Jang, B.H.;Choi, S.;Nah, J.;Lee, S.M.;Chae, J.
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.2
    • /
    • pp.47-52
    • /
    • 2008
  • We have performed the flat-fielding correction for the $H{\alpha}$ full-disk monitoring system of KASI (Korea Astronomy and Space Science Institute), which is installed in the Solar Flare Telescope (SOFT) at the top of Bohyun Mountain. For this, we used a new method developed by Chae (2004), to determine the flat pattern from a set of relatively shifted images. Using this method, we successfully obtained the flat pattern for $H{\alpha}$ full-disk observations and compared our result with the image observed in Catania Astrophysical Observatory. The method that we used in this study seems to be quite powerful to obtain the flat image for solar observations. In near future, we will apply this method for the flat-fielding correction of all solar imaging instruments in KASI.

Power Disturbance Detection using the Inflection Point Estimation (변곡점 추정을 이용한 전력선 신호의 이상현상 검출)

  • Iem, Byeong-Gwan
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.710-715
    • /
    • 2021
  • Power line signal can show disturbances due to various causes. Typical anomalies are temporary sag/swell of the amplitude, flat topped signal, and harmonic distortions. The disturbances need to be detected and treated properly for the quality of the power signal. In this study, the power disturbances are detected using the inflection points (IP). The inflection points are defined as points where local maxima/minima or the slope changes occur. The power line signal has a fixed IP pattern since it is basically sinusoidal, and it may have additional inflection points if there is any disturbance. The disturbance is detected by comparing the IP patterns between the normal signal and distorted signal. In addition, by defining a cost function, the time instant where the disturbance happens can be decided. The computer simulation shows that the proposed method is useful for the detection of various disturbances. The simple sag or swell signal only shows the amplitude changes at the detected inflection points. However, the flat top signal and harmonically distorted signal produce additional inflection points and large values in the cost function. These results can be exploited for the further processing of disturbance classification.