• Title/Summary/Keyword: flat panel

Search Result 750, Processing Time 0.039 seconds

Dynamics and die design in continuous and patch slot coating processes (Continuous 와 pattern slot 코팅 공정에서의 유동특성과 다이 설계)

  • Kim Su-Yeon;Shim Seo-Hoon;Shin Dong-Myeong;Lee Joo-Sung;Jung Hyun-Wook;Hyun Jae-Chun
    • Proceedings of the Korean Society of Rheology Conference
    • /
    • 2006.06a
    • /
    • pp.81-84
    • /
    • 2006
  • Slot coating process, in continuous and patch modes, has been applied for the many precise coating products, e.g., flat panel displays and second batteries. However, manufacturing uniform coating products is not a trivial task at high-speed operations because various flow instabilities or defects such as leaking, bubbles, ribbing, and rivulets are frequently observed in this process. It is no wonder, therefore, that many efforts to understand the various aspects of dynamics and coating windows of this process have been made both in academia and industry. In this study, as the first topic, flow dynamics within the coating bead in slot coating process has been investigated using the one-dimensional viscocapillary model by lubrication approximation and two-dimensional model by Flow-3D software. Especially, operability windows in both 1D and 2D cases with various slot die lip designs have been successfully portrayed. Also, effects of process conditions like viscosity and coating gap size on slot coating window have been analyzed. Also, some experiments to find minimum coating thickness and coating windows have been conducted using slot die coater implemented with flow visualization device, corroborating the numerical results. As the second topic, flow dynamics of both Newtonian and Non-Newtonian fluids in patch or pattern slot coating process, which is employed in manufacturing IT products such as secondary batteries, has been investigated for the purpose of optimal process designs. As a matter of fact, the flow control in this system is more difficult than in continuous case because od its transient or time-dependent nature. The internal die and die lip designs for patterned uniform coating products have been obtained by controlling flow behaviors of coating liquids issuing from slot. Numerical simulations have been performed using Fluent and Flow-3D packages. Flow behavior and pressure distribution inside the slot die has been compared with various die internal shapes and geometries. In the coating bead region, efforts to reduce irregular coating defects in head and tail parts of one patterned coating unit have been tried by changing die lip shapes. It has been concluded that optimal die internal design gas been developed, guaranteeing uniform velocity distribution of both Newtonian and shear thinning fluids at the die exit. And also optimal die lip design has been established, providing the longer uniform coating layer thickness within one coating unit.

  • PDF

Flexible 의료 영상 센서로 적용하기 위한 Flexible ITO substrate의 가스분압 특성 및 Bending의 전기적 특성 연구

  • Gang, Jin-Ho;Hong, Ju-Yeon;Kim, Dae-Guk;O, Gyeong-Min;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.185-185
    • /
    • 2013
  • 최근 의료 영상 센서는 급속도로 발전을 이룩하여 미세 병변의 위치와 그 크기를 진단하는 데에 많은 이용이 되고 있다. 하지만 기존 flat panel형태의 의료영상 센서는 인체의 굴곡으로 인한 영상 왜곡으로 발전의 한계에 이르고 있는 실정이다. 이 영상 왜곡으로 인한 오진은 환자에게 불필요한 피폭, 수술적 요법, 약물치료 등 환자에게 치명적인 의료사고를 일으킬 수 있다. 이러한 한계를 극복하기 위하여 flexible substrate을 이용한 투명전극들이 의료영상 센서로서의 적용을 연구 되어 졌다. IZO, ITO, FTO 등의 투명전극들 중 Indium Tin Oxide(ITO)는 다른 전극에 비해 높은 투명도와 낮은 저항으로 인하여 다양한 부분에서 널리 이용 되고 있다. 그러나 ITO를 flexible substrate로 적용 시 불충분한 resistivity와 기계적 강도를 지니고 있으며, 유연성을 위해 전극 재료의 두께를 감소시키면 전도성의 문제를 일으키는 단점이 있는 것으로 알려져 있다. 이러한 문제점을 보완 및 해결하기 위하여 본 연구에서는 sputtering magnetron system를 이용하여 polyethylene terephthalate(PET) substrate 위에 ITO을 증착함으로써 전기적 특성을 알아보았다. PET 필름의 크기를 55 절단하였고 증착 온도는 고온에서 수축하는 PET 필름의 물성을 고려하여 $23^{\circ}C$로 설정 하였다. 가스의 분압 비를 Ar는 50ccm으로 고정하고 O2의 비율을 각각 0, 0.2, 0.4, 0.8, 1ccm으로 나눈 후, 비율에 따라 각각 30, 60, 90sec간 sputtering 증착을 하였다. 또한 각각 30, 60, 90sec간 sputtering 증착하여 O2 유량과 sputtering 증착 시간의 변화에 따른 ITO의 전도특성과 유연성에 대한 전도특성을 측정하였다. 유연성을 측정하기 위해선 bending 각도를 각각 $0^{\circ}$ $30^{\circ}$, $45^{\circ}$, $60^{\circ}$로 구부린 후, Two-point probe를 이용하여 변화된 저항을 통해 ITO의 전기적 성질의 변화를 측정 하였다. 측정결과 flexible ITO substrate의 전도특성은 sputtering 증착시간이 증가할수록 저항 값이 낮아지는 것을 확인하였지만, O2 유량이 증가 시 저항이 낮아지다가 다시 증가하는 결과를 알 수 있었다. 본 연구에서는 Ar:O2의 50:0.8의 조건에서 90sec동안 sputtering 증착한 ITO가 131 ${\Omega}/cm^2$의 저항 값이 측정 되었고 다른 조건에서는 164 ${\Omega}/cm^2$에서 4.7 $k{\Omega}/cm^2$까지 저항변화를 가져 Ar:O2의 50:0.8의 조건이 최적화에 좋은 조건이라 판단하였다. 또한 50:0.8의 조건의 ITO의 경우 bending test시에서도 131 ${\Omega}/cm^2$에서 316 ${\Omega}/cm^2$ 정도의 안정적인 저항변화를 가지는 반면 다른 조건에서는 128 ${\Omega}/cm^2$에서 6.63 $k{\Omega}/cm^2$까지의 변화를 나타나 기계적 형상변화에도 분압비가 영향을 주는 것을 확인 할 수 가 있었다. bending 각도에 따른 저항의 변화를 측정하였을 시, 각도 변화에 따라 중심부의 저항 값이 $60^{\circ}$에서 가장 높은 변화가 나타나 전기저항이 높아진 원인을 찾기 위해 Scanning Electron Microscope (SEM)촬영을 한 결과 저항값이 높아짐에 따라 ITO의 압축응력이 작용하는 부근에 Crack이 발생함을 알 수 있었다. 이러한 결과로 flexible ITO substrate의 Crack발생률을 최소화 시키고 bending시 전도성을 유지하기 위해서는 가스의 유량 최적화가 flexible substrate의 기계적형상변화에 대한 ITO의 내구성을 향상시킬 수 있는 해답이 될 것으로 사료된다.

  • PDF

Effect of Substrate Temperature and O2 Introduction With ITO Deposition by Electron Beam Evaporation on Polycyclic Olefin Polymer (전자빔으로 폴리사이클릭 올레핀 기판에 ITO 증착시 기판온도 및 산소 도입의 영향)

  • Ahn, Hee-Jun;Ha, KiRyong
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.742-748
    • /
    • 2005
  • Transparent conductive indium-tin oxide (ITO) films are widely used as transparent electrodes for flat panel displays. Many of the ITO films for practical use have been prepared by magnetron sputtering, chemical vapor deposition, electron beam evaporation, etc. An oxide target composed of 10 wt% $SnO_2$ and 90 wt% $In_2O_3$ has been deposited onto polycyclic olefin polymer (POP) substrate by electron beam evaporation. POP has a higher glass transition temperature ($Tg=330^{\circ}C$) than other conventional polymers. In this study, the effects of substrate temperature and the $O_2$ introduction flow rate were investigated in terms of physical, electrical and optical properties of deposited ITO films. We investigated the effects of processing variables such as substrate temperature and the oxygen introduction flow rate. The best electrical and optical properties of deposited ITO films obtained from this study were electrical resistivity value of ${\rho}=1.78{\times}10^{-3}{\Omega}{\cdot}cm$ and optical transmittance of about 85% at 8 sccm (Standard Cubic Centimeter per Minute) $O_2$ introduction flow rate, $5{\AA}/sec$ deposition rate, $1000{\AA}$ deposited ITO thickness and $200^{\circ}C$ substrate temperature.

Evaluation of Stent Apposition in the LVIS Blue Stent-Assisted Coiling of Distal Internal Carotid Artery Aneurysms : Correlation with Clinical and Angiographic Outcomes

  • Kwon, Min-Yong;Ko, Young San;Kwon, Sae Min;Kim, Chang-Hyun;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.801-815
    • /
    • 2022
  • Objective : To evaluate the stent apposition of a low-profile visualized intraluminal support (LVIS) device in distal internal carotid artery (ICA) aneurysms, examine its correlation with clinical and angiographic outcomes, and determine the predictive factors of ischemic adverse events (IAEs) related to stent-assisted coiling. Methods : We retrospectively analyzed a prospectively maintained database of 183 patients between January 2017 and February 2020. The carotid siphon from the cavernous ICA to the ICA terminus was divided into posterior, anterior, and superior bends. The anterior bends were categorized into angled (V) and non-angled (C, U, and S) types depending on the morphology and measured angles. Complete stent apposition (CSA) and incomplete stent apposition (ISA) were evaluated using unsubtracted angiography and flat-panel detector computed tomography. Dual antiplatelet therapy with aspirin 200 mg and clopidogrel 75 mg was administered. Clopidogrel resistance was defined as fewer responders (≥10%, <40%) and non-responders (<10%) based on the percent inhibition (%INH) of the VerifyNow system. These were counteracted by a dose escalation to 150 mg for fewer responders or substitution with cilostazol 200 mg for non-responders. IAEs included intraoperative in-stent thrombosis, transient ischemic attack, cerebral infarction, and delayed in-stent stenosis. A multivariate logistic regression analysis was used to determine the predictive factors for ISA and IAEs. Results : There were 33 ISAs (18.0%) and 27 IAEs (14.8%). The anterior bend angle was narrower in ISA (-4.16°±25.18°) than in CSA (23.52°±23.13°) (p<0.001). The V- and S-types were independently correlated with the ISA (p<0.001). However, treatment outcomes, including IAEs (15.3% vs. 12.1%), aneurysmal complete occlusion (91.3% vs. 88.6%), and recanalization (none of them), did not differ between CSA and ISA (p>0.05). The %INH of 27 IAEs (13.78%±14.78%) was significantly lower than that of 156 non-IAEs (26.82%±20.23%) (p<0.001). Non-responders to clopidogrel were the only significant predictive factor for IAEs (p=0.001). Conclusion : The angled and tortuous anatomical peculiarity of the carotid siphon caused ISA of the LVIS device; however, it did not affect clinical and angiographic outcomes, while the non-responders to clopidogrel affected the IAEs related to stent-assisted coiling.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source (단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구)

  • Park, Yeonok;Cho, Hyosung;Lim, Hyunwoo;Je, Uikyu;Park, Chulkyu;Cho, Heemoon;Kim, Kyuseok;Kim, Guna;Park, Soyoung
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.215-222
    • /
    • 2015
  • In this work, we performed a proof-of-concept experiment for phase-contrast x-ray imaging (PCXI) based on a single antiscatter grid and a polychromatic x-ray source. We established a table-top setup which consists of a focused-linear grid having a strip density of 200 lines/inch, a microfocus x-ray tube having a focal-spot size of about $5{\mu}m$, and a CMOS-type flat-panel detector having a pixel size of $48{\mu}m$. By using our prototype PCXI system and the Fourier demodulation technique, we successfully obtained attenuation, scattering, and differential phase-contrast images of improved visibility from the raw images of several selected samples at x-ray tube conditions of $90kV_p$ and 0.1 mAs. Further, fusion image (e.g., the attenuation+the scattering) may have an advantage in displaying details of the sample's structures that are not clearly visible in the conventional attenuation image. Our experimental results indicate that single-grid-based approach seems a useful method for PCXI with great simplicity and minimal requirements on the setup alignment.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Broadening the Understanding of Sixteenth-century Real Scenery Landscape Painting: Gyeongpodae Pavilion and Chongseokjeong Pavilion (16세기(十六世紀) 실경산수화(實景山水畫) 이해의 확장 : <경포대도(鏡浦臺圖)>, <총석정도(叢石亭圖)>를 중심으로)

  • Lee, Soomi
    • MISULJARYO - National Museum of Korea Art Journal
    • /
    • v.96
    • /
    • pp.18-53
    • /
    • 2019
  • The paintings Gyeongpodae Pavilion and Chongseokjeong Pavilion were recently donated to the National Museum of Korea and unveiled to the public for the first time at the 2019 special exhibition "Through the Eyes of Joseon Painters: Real Scenery Landscapes of Korea." These two paintings carry significant implications for understanding Joseon art history. Because the fact that they were components of a folding screen produced after a sightseeing tour of the Gwandong regions in 1557 has led to a broadening of our understanding of sixteenth-century landscape painting. This paper explores the art historical meanings of Gyeongpodae Pavilion and Chongseokjeong Pavilion by examining the contents in the two paintings, dating them, analyzing their stylistic characteristics, and comparing them with other works. The production background of Gyeongpodae Pavilion and Chongseokjeong Pavilion can be found in the colophon of Chongseokjeong Pavilion. According to this writing, Sangsanilro, who is presumed to be Park Chung-gan (?-1601) in this paper, and Hong Yeon(?~?) went sightseeing around Geumgangsan Mountain (or Pungaksan Mountain) and the Gwandong region in the spring of 1557, wrote a travelogue, and after some time produced a folding screen depicting several famous scenic spots that they visited. Hong Yeon, whose courtesy name was Deokwon, passed the special civil examination in 1551 and has a record of being active until 1584. Park Chung-gan, whose pen name was Namae, reported the treason of Jeong Yeo-rip in 1589. In recognition of this meritorious deed, he was promoted to the position of Deputy Minister of the Ministry of Punishments, rewarded with the title of first-grade pyeongnan gongsin(meritorious subject who resolved difficulties), and raised to Lord of Sangsan. Based on the colophon to Chongseokjeong Pavilion, I suggest that the two paintings Gyeongpodae Pavilion and Chongseokjeong Pavilion were painted in the late sixteenth century, more specifically after 1557 when Park Chung-gan and Hong Yeon went on their sightseeing trip and after 1571 when Park, who wrote the colophon, was in his 50s or over. The painting style used in depicting the landscapes corresponds to that of the late sixteenth century. The colophon further states that Gyeongpodae Pavilion and Chongseokjeong Pavilion were two paintings of a folding screen. Chongseokjeong Pavilion with its colophon is thought to have been the final panel of this screen. The composition of Gyeongpodae Pavilion recalls the onesided three-layered composition often used in early Joseon landscape paintings in the style of An Gyeon. However, unlike such landscape paintings in the An Gyeon style, Gyeongpodae Pavilion positions and depicts the scenery in a realistic manner. Moreover, diverse perspectives, including a diagonal bird's-eye perspective and frontal perspective, are employed in Gyeongpodae Pavilion to effectively depict the relations among several natural features and the characteristics of the real scenery around Gyeongpodae Pavilion. The shapes of the mountains and the use of moss dots can be also found in Welcoming an Imperial Edict from China and Chinese Envoys at Uisungwan Lodge painted in 1557 and currently housed in the Kyujanggak Institute for Korean Studies at Seoul National University. Furthermore, the application of "cloud-head" texture strokes as well as the texture strokes with short lines and dots used in paintings in the An Gyeon style are transformed into a sense of realism. Compared to the composition of Gyeongpodae Pavilion, which recalls that of traditional Joseon early landscape painting, the composition of Chongseokjeong Pavilion is remarkably unconventional. Stone pillars lined up in layers with the tallest in the center form a triangle. A sense of space is created by dividing the painting into three planes(foreground, middle-ground, and background) and placing the stone pillars in the foreground, Saseonbong Peaks in the middle-ground, and Saseonjeong Pavilion on the cliff in the background. The Saseonbong Peaks in the center occupy an overwhelming proportion of the picture plane. However, the vertical stone pillars fail to form an organic relation and are segmented and flat. The painter of Chongseokjeong Pavilion had not yet developed a three-dimensional or natural spatial perception. The white lower and dark upper portions of the stone pillars emphasize their loftiness. The textures and cracks of the dense stone pillars were rendered by first applying light ink to the surfaces and then adding fine lines in dark ink. Here, the tip of the brush is pressed at an oblique angle and pulled down vertically, which shows an early stage of the development of axe-cut texture strokes. The contrast of black and white and use of vertical texture strokes signal the forthcoming trend toward the Zhe School painting style. Each and every contour and crack on the stone pillars is unique, which indicates an effort to accentuate their actual characteristics. The birds sitting above the stone pillars, waves, and the foam of breaking waves are all vividly described, not simply in repeated brushstrokes. The configuration of natural features shown in the above-mentioned Gyeongpodae Pavilion and Chongseokjeong Pavilion changes in other later paintings of the two scenic spots. In the Gyeongpodae Pavilion, Jukdo Island is depicted in the foreground, Gyeongpoho Lake in the middle-ground, and Gyeongpodae Pavilion and Odaesan Mountain in the background. This composition differs from the typical configuration of other Gyeongpodae Pavilion paintings from the eighteenth century that place Gyeongpodae Pavilion in the foreground and the sea in the upper section. In Chongseokjeong Pavilion, stone pillars are illustrated using a perspective viewing them from the sea, while other paintings depict them while facing upward toward the sea. These changes resulted from the established patterns of compositions used in Jeong Seon(1676~1759) and Kim Hong-do(1745~ after 1806)'s paintings of Gwandong regions. However, the configuration of the sixteenth-century Gyeongpodae Pavilion, which seemed to have no longer been used, was employed again in late Joseon folk paintings such as Gyeongpodae Pavilion in Gangneung. Famous scenic spots in the Gwandong region were painted from early on. According to historical records, they were created by several painters, including Kim Saeng(711~?) from the Goryeo Dynasty and An Gyeon(act. 15th C.) from the early Joseon period, either on a single scroll or over several panels of a folding screen or several leaves of an album. Although many records mention the production of paintings depicting sites around the Gwandong region, there are no other extant examples from this era beyond the paintings of Gyeongpodae Pavilion and Chongseokjeong Pavilion discussed in this paper. These two paintings are thought to be the earliest works depicting the Gwandong regions thus far. Moreover, they hold art historical significance in that they present information on the tradition of producing folding screens on the Gwandong region. In particular, based on the contents of the colophon written for Chongseokjeong Pavilion, the original folding screen is presumed to have consisted of eight panels. This proves that the convention of painting eight views of Gwangdong had been established by the late sixteenth century. All of the existing works mentioned as examples of sixteenth-century real scenery landscape painting show only partial elements of real scenery landscape painting since they were created as depictions of notable social gatherings or as a documentary painting for practical and/or official purposes. However, a primary objective of the paintings of Gyeongpodae Pavilion and Chongseokjeong Pavilion was to portray the ever-changing and striking nature of this real scenery. Moreover, Park Chung-gan wrote a colophon and added a poem on his admiration of the scenery he witnessed during his trip and ruminated over the true character of nature. Thus, unlike other previously known real-scenery landscape paintings, these two are of great significance as examples of real-scenery landscape paintings produced for the simple appreciation of nature. Gyeongpodae Pavilion and Chongseokjeong Pavilion are noteworthy in that they are the earliest remaining examples of the historical tradition of reflecting a sightseeing trip in painting accompanied by poetry. Furthermore, and most importantly, they broaden the understanding of Korean real-scenery landscape painting by presenting varied forms, compositions, and perspectives from sixteenth-century real-scenery landscape paintings that had formerly been unfound.