• 제목/요약/키워드: flashing

검색결과 108건 처리시간 0.021초

속도저감형 시설이 차량 주행 속도에 미치는 영향 분석 (Effects on the Vehicle Running Speed Analysis according to the Speed Reduction Road Facilities)

  • 강수철;유순덕;조규철
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.158-170
    • /
    • 2016
  • It has been applied several ways in order to prevent traffic accidents and speed management on the road which is one of very important factors to prevent accidents. In this study, it is analyzed whether the facility such as the flashing and crosswalk, speed cameras and intermittent warning signs affect on a driving deceleration or not. It has been shown that the flashing and crosswalk and speed cameras except intermittent warning signs play a role of reducing the driving speed. The result showed that these traffic safety facilities help to improve the average speed as well as velocity distribution which was derived by the speed deviation even if there were the difference between facilities. Speed limit display does not affect the deceleration of the driver. Therefore, it was founded in this research that there were the driving speed reduction effect due to the facilities on the road. In order to control the driving speed on the road, it is necessary to install facilities with appropriate location and spacing on the road. In addition, place that turns out suppressed speeding through speed management also are required adequate facilities such as speed cameras.

상대적인 위치지각의 왜곡: 참조자극의 위치가 왜곡에 미치는 영향 (Relative localization errors: The effect of reference location on the errors)

  • Li, Hyung-Chul
    • 인지과학
    • /
    • 제15권3호
    • /
    • pp.15-24
    • /
    • 2004
  • 추적 눈 운동 동안에 순간적으로 노출되는 표적의 위치는 표적 주위에 참조자극이 존재하지 않을 때에 일반적으로 눈 운동 방향으로 왜곡되어 지각된다. 본 연구는 안정적이고 정적인 참조자극이 존재하는 경우에 순간적으로 노출되는 표적의 참조자극에 대한 상대적인 위치가 얼마나 정확하게 지각되는지를 검증하였다. 참조자극에 대한 표적의 상대적인 위치가 왜곡되게 지각되었으며 상대적인 위치 지각 왜곡의 양상이 참조자극과 표적의 상대적인 위치에 따라서 체계적으로 변화하였다. 동일한 실험결과가 추적 눈 운동의 방향이 상이하거나 참조자극과 표적의 다양한 물리적인 거리 조건에서도 일관되게 관찰되었다. 본 연구의 실험결과가 위치지각에 관하여 제안된 기존의 이론에 의해 어떻게 설명될 수 있는지를 논의하였다.

  • PDF

후래시 현상을 수반하는 수직증발관내에서의 2상유동에 관한 실험적 연구 (Experimental study on two-phase flow behavior inside a vertical tube evaporator under flashing phenomenon)

  • 이상용;송시홍;이상호
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.833-846
    • /
    • 1988
  • 본 연구에서는 후래시현상과 가열이 동시에 존재하면서 증발을 일으키는 수직 증발관내에서의 유동양식에 대해서, 우선 전기 프로우브를 이용하여 관내의 유동양식 에 따른 전기적 신호를 얻고, 시진실험 방법(photographic experimental method)을 통 하여 이를 확인한다. 또한, 전기 프로우브를 통하여 얻은 신호는 적절한 해석과정을 통해 수직 증발관내의 유동에 따른 기공률을 측정하는데 적용된다.

고압 저등급탄-이산화탄소 슬러리 분무특성에 관한 연구 (Spray Characteristics of a Coal Slurry with Liquid Carbon Dioxide)

  • 김창연;김학덕;송주헌
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.357-362
    • /
    • 2015
  • There is potential method to utilize the liquid carbon dioxide ($LCO_2$) in coal gasification plants. The $LCO_2$ could be used to effectively transport coal particles instead of conventional carrier such as liquid water ($H_2O$) particularly in wet-fed gasifier. However, there is a lack of fundamental study on the atomization behavior of $LCO_2$ coal slurry under high pressure condition. In this study, the flashing spray characteristics of a coal mixture with $LCO_2$ was examined during a throttling process by using a flow visualization system. The spray of coal water slurry which is in the Rayleigh-type break up mode was significantly different. This difference indicates that the coal water slurry did not effectively transport the coal, as compared to $LCO_2$ coal slurry.

Heat transfer and flow characteristics of a cooling thimble in a molten salt reactor residual heat removal system

  • Yang, Zonghao;Meng, Zhaoming;Yan, Changqi;Chen, Kailun
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1617-1628
    • /
    • 2017
  • In the passive residual heat removal system of a molten salt reactor, one of the residual heat removal methods is to use the thimble-type heat transfer elements of the drain salt tank to remove the residual heat of fuel salts. An experimental loop is designed and built with a single heat transfer element to analyze the heat transfer and flow characteristics. In this research, the influence of the size of a three-layer thimble-type heat transfer element on the heat transfer rate is analyzed. Two methods are used to obtain the heat transfer rate, and a difference of results between methods is approximately 5%. The gas gap width between the thimble and the bayonet has a large effect on the heat transfer rate. As the gas gap width increases from 1.0 mm to 11.0 mm, the heat transfer rate decreases from 5.2 kW to 1.6 kW. In addition, a natural circulation startup process is described in this paper. Finally, flashing natural circulation instability has been observed in this thimble-type heat transfer element.

Studies on Biological Diversity of Firefly in Japan

  • Suzuki, Hirobumi
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제2권2호
    • /
    • pp.91-105
    • /
    • 2001
  • Taxonomic and phylogenetic studies of firefly in Japan have been reviewed. Fourty-six lampyrid species and one rhagophthalmid are distributed in the Japanese Islands including the Ryukyus. Recently, molecular phylogenetic approaches have been employed in the systematic study of firefly using mitochondrial and luciferase genes. Based on the molecular phylogenetic trees, evolutionary process of flashing patterns related strictly to mating behavior was estimated. Furthermore, genetic diversity studies revealed geographic differentiation patterns within species, and conservation measures of firefly were proposed to protect genetic resources endemic to the localities.

  • PDF

시선 고정 유도방법이 시야 검사에 미치는 영향 (The Effect of Gaze Fixation Induction Method on Visual Field Testing)

  • 이지형;최영근;;이나현;오건희;김영균;강자헌;유희천
    • 대한산업공학회지
    • /
    • 제42권6호
    • /
    • pp.412-420
    • /
    • 2016
  • A visual field tester using a fixation target with a lack of distinctiveness decreases accuracy and usability in visual field testing. The present study is intended to develop various induction methods of gaze fixation for effective visual field testing. Proposed were four new gaze fixation induction methods (color changing dot; alphanumeric characters; flashing black dot; and bulls eye and cross hair, BECH) by considering visual attention factors such as color, meaning, flashing, and shape and the proposed methods were compared with the existing black dot (BD) method in terms of gaze fixation performance and subjective satisfaction by 32 participants in their 20s to 30s. BECH was found most preferred by increasing gaze fixation performance by 4.8% and subjective satisfaction by 0.4 to 2.0 in a 7-point scale compared to BD. BECH can be applied to tests such as visual field testing and macular pigment optical density testing in which gaze fixation is crucial for accuracy and usability.

Economic Evaluation of Coupling APR1400 with a Desalination Plant in Saudi Arabia

  • Abdoelatef, M. Gomaa;Field, Robert M.;Lee, YongKwan
    • 시스템엔지니어링학술지
    • /
    • 제12권1호
    • /
    • pp.73-87
    • /
    • 2016
  • Combining power generation and water production by desalination is economically advantageous. Most desalination projects use fossil fuels as an energy source, and thus contribute to increased levels of greenhouse gases. Environmental concerns have spurred researchers to find new sources of energy for desalination plants. The coupling of nuclear power production with desalination is one of the best options to achieve growth with lower environmental impact. In this paper, we will per-form a sensitivity study of coupling nuclear power to various combinations of desalination technology: {1} thermal (MSF [Multi-Stage Flashing], MED [Multi-Effect Distillation], and MED-TVC [Multi-Effect Distillation with Thermal Vapour Compression]); {2} membrane RO [Reverse Osmosis]; and {3} hybrid (MSF-RO [Multi-Stage Flashing & Reverse Osmosis] and MED-RO [Multi-Effect Distillation & Reverse Osmosis]). The Korean designed reactor plant, the APR1400 will be modeled as the energy production facility. The economical evaluation will then be executed using the computer program DEEP (Desalination Economic Evaluation Program) as developed by the IAEA. The program has capabilities to model several types of nuclear and fossil power plants, nuclear and fossil heat sources, and thermal distillation and membrane desalination technologies. The output of DEEP includes levelized water and power costs, breakdowns of cost components, energy consumption, and net saleable power for any selected option. In this study, we will examine the APR1400 coupled with a desalination power plant in the Kingdom of Saudi Arabia (KSA) as a prototypical example. The KSA currently has approximately 20% of the installed worldwide capacity for seawater desalination. Utilities such as power and water are constructed and run by the government. Per state practice, economic evaluation for these utilities do not consider or apply interest or carrying cost. Therefore, in this paper the evaluation results will be based on two scenarios. The first one assumes the water utility is under direct government control and in this case the interest and discount rate will be set to zero. The second scenario will assume that the water utility is controlled by a private enterprise and in this case we will consider different values of interest and discount rates (4%, 8%, & 12%).

오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석 (Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

액적충돌침식으로 인한 배관감육 예측체계 구축에 관한 연구 (A Study on the Development of Prediction System for Pipe Wall Thinning Caused by Liquid Droplet Impingement Erosion)

  • 김경훈;조연수;황경모
    • Corrosion Science and Technology
    • /
    • 제12권3호
    • /
    • pp.125-131
    • /
    • 2013
  • The most common pipe wall thinning degradation mechanisms that can occur in the steam and feedwater systems are FAC (Flow Acceleration Corrosion), cavitation, flashing, and LDIE (Liquid Droplet Impingement Erosion). Among those degradation mechanisms, FAC has been investigated by many laboratories and industries. Cavitation and flashing are also protected on the piping design phase. LDIE has mainly investigated in aviation industry and turbine blade manufactures. On the other hand, LDIE has been little studied in NPP (Nuclear Power Plant) industry. This paper presents the development of prediction system for pipe wall thinning caused by LDIE in terms of erosion rate based on air-water ratio and material. Experiment is conducted in 3 cases of air-water ratio 0.79, 1.00, and 1.72 using the three types of the materials of A106B, SS400, and A6061. The main control parameter is the air-water ratio which is defined as the volumetric ratio of water to air (0.79, 1.00, 1.72). The experiments were performed for 15 days, and the surface morphology and hardness of the materials were examined for every 5 days. Since the spraying velocity (v) of liquid droplets and their contact area ($A_c$) on specimens are changed according to the air-water ratio, we analyzed the behavior of LDIE for the materials. Finally, the prediction equations(i.e. erosion rate) for LDIE of the materials were determined in the range of the air-water ratio from 0 to 2%.