• Title/Summary/Keyword: fixture loading

Search Result 123, Processing Time 0.032 seconds

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

Abutment Sinking and Fitness of Conical Internal Connection Implant System according to Loading Condition (하중조건에 따른 원추형 내측연결 임플랜트 시스템에서 지대주 침하 및 적합에 관한 연구)

  • Lee, Hal-La;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.77-89
    • /
    • 2008
  • The purpose of this study was to evaluate internal conical abutment sinking and fitness according to the loading condition. In this study, Alloden implant fixture and two abutment(conventional, FDI) systems were used. Each abutment was applied 1 time of finger force, 3 times of malleting force, 5 times of 20kg and extra several times to the fixture until the amount of abutment singking showed no change. Then, the length of abutment to fixture which was binding lightly with no pressure state was measured by Vernier caliper. After loading application, the length was remeasured and the amount of sinking was calculated. The implant was buried in unsaturated polyester (Epovia, Cray Valley Inc. Korea) for making a comparison between the change of length and fitness of abutment-fixture connection part. Then All samples were cross-sectioned with high speed precision cut-off(accutom-5, Struers, Denmark). Finally, The result were observed and analyzed using FE-SEM (field emission scanning electron microscopy).

Finite Element Analysis of Stress Distribution on Supporting Bone of Cement Retained Implant by Oblique Loading (경사하중에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분포)

  • Lee, Myung-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.343-349
    • /
    • 2014
  • The dental osseointegration implant should be enough to endure occlusion load and it's required to have efficient design and use of implant to disperse the stress into bones properly. Solidworks as a finite element analysis program for modeling and analysis of stress distribution was used for the research. The simple crown model was designed on applying conjoined condition with tightening torque of 20 Ncm of a abutment screw between a cement retained implant abutment and a fixture. A $45^{\circ}$ oblique loading from lingual to buccal side on buccal cusps of crown and performed finite element analysis by 100 N of external load. The results by a analysis for stress distribution of supporting bones of fixture were as below. The von Mises stress was concentrated on the upper side of supporting compact bone regardless of the diameters and lengths of fixture, and the efficiency result of stress reduction was increase of fixture's diameter than it's length. Therefore, it's effective to use wider fixture as possible to the conditions of supporting jaw bone.

Stress analysis on the implant fixture with the angulated placement (경사진 임플란트 고정체의 응력 분석)

  • Kim, Chang-Hyeon;Kang, Jae-Suek;Boo, Soo-Bung;Oh, Snag-Ho;An, OK-Ju;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.71-81
    • /
    • 2004
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models of two units implant prosthesis with one angulated placement of two implant fixtures. The two unit implant crowns simulated to mandibular first and second molars were made. The two kinds of finite element models were designed according to angulation of fixture ($4.0mm{\times}11.5mm$) : Model 1($15^{\circ}$ buccally angulated placement of one fixture on second molar area), Model 2($15^{\circ}$ lingually angulated placement of one fixture on second molar area). Axial loads of 200N were applied to the center of central fossa and to distance of 2mm and 4mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the fixtures, and buccolingual section of implants. The results were as follows: 1. Under axial loading at the central fossa, the stress was distributed along the straight fixture except apical portion, while on buccally or lingually angulated placement, the highest stresses were concentrated in the neck portion on the opposite side of the angulated fixture. 2. With offset distance increasing, the stresses were concentrated greater in buccal neck of lingually angulated fixture than in lingual neck of buccally angulated fixture. From the above results, in designing of the occlusal scheme for implant prosthesis with the angulated fixture, occlusal contacts should be placed to distribute stress axially in maximum intercuspation and to avoid offset force during eccentric movements.

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY (임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구)

  • Yang Jae-Sik;Vang Mong-Sook;Jo Gyu-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.

Loadability Analysis of Modular Fixtures based on a Configuration Space Approach (형상공간 접근 방식에 기반한 모듈식 고정쇠의 적재가능성 분석)

  • 유견아
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.5
    • /
    • pp.398-406
    • /
    • 2003
  • In modular fixturing systems, a given part or a subassembly is fixed by placing fixture elements such as locators and clamps adequately on a plate with a lattice of holes. It is known that the minimal number of point contacts to restrict translational and rotational motions on a plane is four and the type of three locators and a clamp(3L/1C) is the minimal future. Brost and Goldberg developed the complete algorithm to automatically synthesize 3L/1C types of fixtures which satisfy the condition of form closure. Due to the nature of the fixture, the clearance between the fixture and the part is extremely small. It is hard to load the part repeatedly and accurately for human as well as for robot. However the condition of loadability has not been taken into account in the B&G algorithm. In this paper, a new method to decide a given fixture to be loadable by using configuration space is proposed. A method to plan for a part to be loaded by using compliance safely even in the presence of control and sensing uncertainty is proposed is well.

Three dimensional finite element analysis of the fully bone anchored bridge and implant-supported overdenture in edentulous mandible (무치하악에서 임플랜트를 이용한 고정성 및 가철성 보철물의 삼차원 유한요소 분석)

  • Lim, Heon-Song;Cho, In-Ho;Lim, Ju-Hwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.251-276
    • /
    • 2002
  • The purpose of this study was to compare and analyze the stress distribution and displacement of the fully bone anchored bridge and implant-supported overdenture in edentulous mandible on certain conditions such as number of implants, different design of superstructure. Three dimensional analysis was used and nine kinds of models designed for this study. FEM models were created using commercial software[$Rhinoceros^{(R)}$ (Ver. 1.0 Robert McNeel & Associates, USA)], and analyze using commercial software [Cosmos/$Works^{TM}$(Ver. 4.0 Structural Research & Analysis Corp., US A)]. A vertical load and $45^{\circ}$ oblique load of 17kgf were applied at the left 1st. molar. The results were as follows : (1) In the group of OVD, the displacement was reduced as increasing the number of fixture under vertical loading but there was no specific difference in Von Mises stress. Under oblique loading, the displacement was same at the vertical loading but Von Mises stress was reduced in order of OVD-3, OVD-4, OVD-2. But, bending moment reduced according to increasing the number of fixture. (2) In the group of FBAB, under vertical and oblique loading, the magnitude of Von Mises stress and displacement reduced according to increasing the number of fixtures. FBAB-4 and FBAB-5 showed similar score and distribution, but FBAB-6 showed lower value relatively. (3) In cantilever design, the maximum displacement reduced under vertical loading but increased under oblique loading. However, von mises stresses on fixtures increased under vertical and oblique loading. (4) In comparing OVD-group with FBAB-group, FBAB showed low magnitude of displacement in respect of oblique loading. However OVD-group was more stable in respect of stress distribution.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS (내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구)

  • Kim Yu-Lee;Cho Hye-Won;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.

전기체 정적시험 치구설계 기술보고서

  • Kim, Sung-Chan;Shin, Jeong-Woo;Shim, Jae-Yeul;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.32-44
    • /
    • 2002
  • This paper contains the information that describes the test fixture design and technology for full-scale airframe static test. Obtained technologies consist of determination of design load for test fixture, design technique for loading system, counterbalance system, positioning system of test article, test equipment and overload protection method. Full-scale airframe static test of advanced jet trainer was implemented using test fixture which are applied these technique.

  • PDF

STUDY ON RADIOGRAPHIC EVALUATION OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANT AFTER FUNCTIONAL LOADING (기능적 부하 후 임플란트 주변의 골 흡수에 대한 방사선학적 연구)

  • Choi, Su-Jin;Chee, Young-Deok;Koh, Se-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.240-247
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS II, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.