• Title/Summary/Keyword: fixing wastewater

Search Result 13, Processing Time 0.025 seconds

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.

  • PDF

Treatment of Photographic Wastewater by Chemical Oxidation and Biological Treatment process (화학적산화 및 생물학적처리법에 의한 사진폐액의 처리)

  • 정경훈;최형일
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.34-42
    • /
    • 1997
  • A laboratory experiments were performed to investigate the treatment of photographic processing wastewater by chemical oxidation and biological treatment system. The effect of reaction conditions such as hydrogen peroxide dosage, ferrous sulfate dosage and pH on the COD removal in Fenton oxidation were investigated. The optimal dosage of hydrogen peroxide was 2.58 M and 3.87 M for the developing and fixing process wastewater, respectively. The Fenton oxidation was most efficient in the pH range of 3-5 and the optimal condition for initial reaction pH was 5 for a developing process wastewater. With iron powder catalyst, the COD for a developing process wastewater was removed in lower pH than with ferrous sulfate catalyst. The removal efficiency of COD for refractory compounds such as Diethyleneglycol, Benzylalcohol, Hydroxylamine Sulfate, Ammonium Thiosulfate, Ammonium Ferric EDTA and Disodium EDTA in the photogaphic wastewater was found than 90% except Potassium Carbonate. When the photographic processing wastewater after pretreatment by Fenton oxidation was treated with batch activated sludge process, the addition of $KH_2PO_4$ as a phosphorous compound improved the removal efficiency of COD. During the continuous biological treatment of developing and fixing process wastewater after pretreatment by Fenton oxidation, the effluent COD concentration less than 100 mg/l was obtained at 0.425 and 0.25 kgCOD/m$^3$.d, respectively.

  • PDF

A Study on Pre-Red Mud and Bio-Solids Applicability as Soil Stabilizer (Pre-Red Mud 및 Bio-Solids의 토양 안정화제 활용 가능성에 대한 연구)

  • Yang, Joo-Kyung;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.419-428
    • /
    • 2011
  • Recycling as a stabilizer of industrial by-product can be terms of the proper handling of industrial by-product and positive side in terms of recycling of waste. This study was performed to evaluate has the possibility as stabilizer by primary processing Pre-Red Mud and Bio-Solids which are generated as waste in soils contaminated with heavy metals and compared the efficiency with steel slug being applied in an existing site. In evaluation of the arsenic-fixing ability of stabilizer in batch test, Bio-Solids have the similar arsenic-fixing ability with Pre-Red Mud, which shows 17% h igher arsenic-fixing ability than PS Ball. Since the stabilization periods using Bio-Solids and Pre-Red Mud are faster than the PS Ball, they seems to be better stabilizer than PS Ball to decrease the leaching of arsenic in contaiminated soil.

Growth and Cyanide Degradation of Azotobacter vinelandii in Cyanide-Containing Wastewater System

  • Koksunan, Sarawut;Vichitphan, Sukanda;Laopaiboon, Lakkana;Vichitphan, Kanit;Han, Jaehong
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.4
    • /
    • pp.572-578
    • /
    • 2013
  • Azotobacter vinelandii, a strict aerobic nitrogen-fixing bacterium, has been extensively studied with regard to the ability of $N_2$-fixation due to its high expression of nitrogenase and fast growth. Because nitrogenase can also reduce cyanide to ammonia and methane, cyanide degradation by A. vinelandii has been studied for the application in the bioremediation of cyanide-contaminated wastewater. Cyanide degradation by A. vinelandii in NFS (nitrogen-free sucrose) medium was examined in terms of cell growth and cyanide reduction, and the results were applied for cyanide-contaminated cassava mill wastewater. From the NFS medium study in the 300 ml flask, it was found that A. vinelandii in the early stationary growth phase could reduce cyanide more rapidly than the cells in the exponential growth phase, and 84.4% of cyanide was degraded in 66 h incubation upon addition of 3.0 mM of NaCN. The resting cells of A. vinelandii could also reduce cyanide concentration by 90.4% with 3.0 mM of NaCN in the large-scale (3 L) fermentation with the same incubation time. Finally, the optimized conditions were applied to the cassava mill wastewater bioremediation, and A. vinelandii was able to reduce the cyanide concentration by 69.7% after 66 h in the cassava mill wastewater containing 4.0 mM of NaCN in the 3 L fermenter. Related to cyanide degradation in the cassava mill wastewater, nitrogenase was the responsible enzyme, which was confirmed by methane production. These findings would be helpful to design a practical bioremediation system for the treatment of cyanide-contaminated wastewater.

A study on Blood pigments removal of butchery wastewater by heat processed Eggshell (Heat processed Eggshell에 의한 도축폐수의 혈색소 제거에 관한 연구)

  • 박경식
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.37-43
    • /
    • 2000
  • The purpose of this experimental study examine characteristics of blood pigments removal of butchery wastewater by heat processed eggshell, compare activated carbon with its efficiency. Calcined eggshell were classified into four kinds of mesh as HPES-32(Heat Processed Eggshell 32 $mesh=500{\mu}m$), HPES-48($300{\mu}m$), HPES-150($180{\mu}m$) and HPES-150($106{\mu}m$). And two contacting process of CMFA(Complete Mixing Float Adsorption) and FLFA(Fixing layer Flow Adsorption) Were used for getting removal efficiency of blood pigments. In case of using CMFA process, the removal efficiency of blood pigments was occurred as HPES-80>HPES-150>HPES-32, but in case of using FLFA process was occurred as HPES-150>HPES-80>HPES-48>HPES-32. The two results between CMFA and FLFA were differ in strength of removal efficiency of blood pigments.

  • PDF

Treatability Prediction Method for Nanofiltration Systems in Drinking Water Treatments (정수처리에 이용되는 나노여과막시스템의 성능예측방법 확립)

  • Kang, Meea;Itoh, Masaki
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.572-581
    • /
    • 2005
  • This research is conducted to develop predictable method of real scale nanofiltration treatability with small scale nanofiltration experiments. As a result of comparing calculated values with measured values, they are in a good agreement for the concentrations in filtered water and concentrated water. The results of that are not affected by change of system recovery from 20% to 95%. The proposed method is produced using constant recovery of elements, that is, no considering the pressure change. we can predict filtrated flux and contaminant concentrations with the method. The method has the following steps. (1) Calculate recovery of each element with water quality level after fixing recovery elements, (2) Predict system recovery with recovery of elements in 1, 2, 3, and 4 banks, (3) Run small scale nanofiltration experiments in predicted water quality and (4) Simulate large scale nanofiltration system for forecasting actual water quality. As the cost for nanofiltration pretest will reduced if we use the proposed method, it will be a promising method for introducing nanofiltration to supply safe drinking water.

Optimal Design of Water Distribution Networks using the Genetic Algorithms:(II) -Sensitivity Analysis- (Genetic Algorithm을 이용한 상수관망의 최적설계: (II) -민감도 분석을 중심으로-)

  • Shin, Hyun-Gon;Park, Heekyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.50-58
    • /
    • 1998
  • Genetic Algorithm (GA) consists of selection, reproduction, crossover and mutation processes and many parameters including population size, generation number, the probability of crossover (Pc) and the probability of mutation (Pm). Determining values of the parameters is found critical in the whole optimization process and a sensitivity analysis with them seems mandatory. This paper tries to demonstrate such importance of sensitivity analysis of GA using an example water supply tunnel network of the New York City. For optimization of the network with GA, Pc and Pm vary from 0.5 to 0.9 by an increment of 0.1 and from 0.01 to 0.05 by an increment of 0.01, respectively, while fixing both the population size and the generation number to 100. This sensitivity analysis results in an optimum design of 22.3879 million dollars at the values of 0.8 and 0.01 for Pc and Pm, respectively. In addition, the probability of recombination (Pr) is introduced to check its applicability in the GA optimization of water distribution network. When Pr is 0.05 with the same values of Pc and Pm as above, the optimum design costs 20.9077 million dollars. This is lower than the cost of 22.3879 million dollars for the case of not using Pr by 6.6%. These results indicate that conducting a sensitivity analysis with parameter values and using Pr are useful in the optimization of WDN.

  • PDF

Isolation and identification of a phenol-degrading bacterium from the sewage sludge (하수슬러지로부터 페놀분해세균의 분리 및 동정에 관한 연구)

  • Kim, Young-Jun;Lee, Suk-Won;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2004
  • A bacterium which grow on phenol as an only carbon and energy source was isolated from the sewage sludge at Nangi municipal wastewater treatment plant in Seoul. This bacterium was found to be a Gram negative rod with high motility, and well grew on 0.05%, 0.1%, and 0.15% of phenol. No matching strain was found from the result of the BBL test. Phylogenetic analysis of the strain by comparison of the 16s-rDNA has revealed that this bacterium has 99% of similarity with Stenotrophomonas maltophilia strain of Xanthomonas group, which belongs t the Gamma (${\gamma}$) subdivision of Proteobacteria. This strain has also shown 98% of similarity with nitrogen fixing bacterium MAGDE3 and Pseudomonas cissicola strain, and 97% of similarity with Stenotrophomonas sp. LMG198 and Xanthomonas cucurbitae.

  • PDF

Wastewater Treatment by using a Rotating Photocatalitic Oxidation Disk System (회전광촉매 시스템에 의한 폐수처리)

  • Chung, Ho Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5B
    • /
    • pp.497-502
    • /
    • 2009
  • The wastewater treatment by photocatalyst decomposes pollutants directly in water, and it is easy to decompose indecomposable organics and inorganic. and Especially, it has an advantage that there is no secondary production of pollutants. However, there will be many problems which are generated depending on the type of photocatalyst. The type of rotating photocatalyst minimizes previous problems, and advanced oxidation processes is possible by the application of rotating disc method. The consideration of the characteristics about various designs and operation factors is needed for the application of rotating photocatalyst system. In this study, rotating photocatalyst was manufactured for rotating disc method by fixing of $TiO_2$. The operation factors were derived for the wastewater treatment by the reaction of rotating photocatalyst. The contained quantity of $TiO_2$ was limited about 70%. The more the contained quantity of $TiO_2$ was increased, the more the treatment rate was continually increased. The optimum rotating photocatalyst was R4, and the contained quantity of $TiO_2$ was 36.8%. The more the exposed amount of UV is increased, the more the decomposition effect of TCODcr was continually increased. However, the adequate strength of light source must be determined by the consideration of economical efficiency. The more the speed of rotating photocatalyst is increased, the more treatment efficiency was increased. When UV lamp was not submerged in reactor, the wastewater treatment was efficient in the order of the depth of water 50%, 30%, 10%, 70%, 100%. This study is a basic research for the development of a system which treats organics in solar light.

An Experimental Study for Practical Application of RBC (RBC의 실제적용(實際適用)을 위한 실험연구(實驗硏究))

  • Kim, Hee-Jeong;Ahn, Yong-Tae
    • Korean Journal of Environmental Agriculture
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 1985
  • Recently the method using fixing biological contactor in treatment of sewage and wastewater has been propelling on the ground that it has advantages of reducing both motive and man power and applied treatment plants of this method are increasing gradually in Korea. After analysing the results from which real structure pilot plant had operated in the field with RBC sewage wastewater system-one of the fixing biological contact methods-for five months, this study was performed to investigate how to apply the standard of establishment that provided in article of sewage disposal facilities notified (act 8 of art 84) by the office of environment on May 16, 1984, to real treatment plant. The rotating velocity and the staying time of rotating disc have interrelation on removal efficiency of BOD. When circumferential velocity of rotating disc was ranged from 18 to 20 m per minute, economical price was the best. When the staying time was even about 120 minutes for that of home RBC facilities showed 90% or above of BOD removal efficiency of high concentration sewage also showed excellent efficiency ranged from about 85% to 90%.

  • PDF