• Title/Summary/Keyword: fixing

Search Result 1,192, Processing Time 0.025 seconds

유닛모듈 운반용 고정장치의 하중거동 비교 분석 (A comparative analysis of load behavior of the fixing equipments for transporting unit modules)

  • 김균태;김석;전영훈;김태영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.146-147
    • /
    • 2015
  • This paper compares load behavior of two fixing equipments for transporting unit modules. The suggested fixing equipment shows higher limit load than an existing fixing equipment, which proves that the suggested fixing equipment have higher safety.

  • PDF

광굴절 결정에서의 홀로그램 Fixing에 관한 연구 (Hologram Fixing in Photorefractive Crystal)

  • 황성모;이혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.379-381
    • /
    • 1994
  • Volume holograms recorded in photorefractive materials can find important applications in optical memories and optical computing systems. One problem with a photorefractive hologram is that it gets erased by the readout light. Nondestructive readout can be achieved by hologram fixing, and several fixing methods have been reported. Fixing is accomplished by thermally activated motion of an unknown ionic defect, which neutralizes the electronic space-charge patterns. At room temperature the ionic patterns are stabilized. When the electrons are partially redistributed by light, a net space-charge pattern appears, and tile fixed hologram can be read out. In this paper, theoretical modeling and some experimental results are presented for thermal fixing of volume phase holograms in photorefractive $LiNbO_3$:Fe. Thermal fixing can be done during or after recording and depends on fixing temperature ($100{\sim}200^{\circ}C$ range) and grating length. Fixed Slating can be erased completely at the temperature over $300^{\circ}C$. Theoretical modeling shows weil the compensation of electronic Slating by ionic grating and is in good agreement with experimental results. In experiments the dependence of thermal fixing on temperatures and grating lengths is investigated.

  • PDF

천연물질을 활용한 웰빙기법 천연염색에 관한 연구 (2) -소엽염색 면직물의 모나자이트 처리효과- (A Study on the Well-being Technique Natural Dyeing with Natural Resources (2) -Effect of Monazite Treatment on the Cotton Fabric with Natural Dyeing using Perilla frutescens var. acuta -)

  • 김상률
    • 한국의류산업학회지
    • /
    • 제12권2호
    • /
    • pp.240-245
    • /
    • 2010
  • The effects of monazite and fixing agents on cotton fabric dyed with Perilla frutescens var. acuta extract were investigated. The proper monazite treatment concentration, temperature and time were 10%(o.w.b.), $50^{\circ}C$ and 60minutes. By various fixing agent treatment, $FeSO_4$ showed a relatively high K/S value and the order of K/S value decreased as follows, cation surface active agents, soybean and NaCl. And the monazite and $FeSO_4$ fixing agent showed higher anion emissity than those of untreated cotton and other fixing agents. The cotton fabrics showed improved color fastness by monazite and fixing agents treatments with the exception of light fastness. And the cotton fabrics fixed with fixing agents were showed effective bacterial reduction with the exception of NaCl.

손가락 재활로봇의 5축 힘/모멘트센서를 이용한 손 누름제어 (Hand Pressing Control Using the Five-Axis Force/Moment Sensor of Finger Rehabilitation)

  • 김현민;김갑순
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.192-197
    • /
    • 2012
  • This paper describes the control of the hand fixing system attached to the finger rehabilitation robot for the rehabilitation exercise of patient's fingers. The finger rehabilitation robot is used to exercise the finger rehabilitation, and a patient's hand is safely fixed using the hand fixing system. In this paper, the hand fixing system was controlled with PD gains to fix a palm of the hand, and the characteristic test for the hand fixing system was carried out to sense the fixed hand movement of the front and the rear, that of the left and the right, and that of the upper. It is thought that the hand fixing system could safely fix the hand, and the movement of the fixed hand could be perceived using the five-axis force/moment sensor attached to the hand fixing system.

유한요소기법을 이용한 고소작업대의 파손된 고정볼트의 피로 파손 분석 (A Fatigue Failure Analysis of Fractured Fixing Bolts of a Mobile Elevating Work Platform using Finite Element Methods)

  • 최동훈;김재훈
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.1-8
    • /
    • 2020
  • Mobile elevating work platforms (MEWPs) consist of a work platform, extending structure, and chassis, and are used to move persons to working positions. MEWPs are useful but are composed of pieces of equipment, and accidents do occur owing to equipment defects. Among these defects, accidents caused by the fracture of bolts fixed to the extension structure and swing system are increasing. This paper presents a failure analysis of the fixing bolts of MEWP. Standard procedure for failure analysis was employed in this investigation. Visual inspection, chemical analysis, tensile strength measurement, microstructural characterization, fractography analysis by Optical Microscope(OM) and Scanning Electron Microscopy(SEM), and finite element analysis (FEA) were used to analyze the failure of the fixing bolts. Using this failure analysis approach, we found the root cause of failure and proposed a means for solving this type of failure in the future. First, the chemical composition of the fixing bolt is obtained by a spectroscopy chemical analysis method, which determined that the chemical composition matched the required standard. The tensile test showed that the tensile and yield strengths were within the required capacity. The stress analysis was carried out at five different boom angles, and it was determined that the fixing bolt of MEWP can withstand the loads at all the boom angles. The outcomes of the fatigue analysis revealed that the fixing bolt fails before reaching the design requirements. The results of the fatigue analysis showed primarily that the failure of the fixing bolt was due to fatigue. A visual inspection of the fractured section of the fixing bolt also confirmed the fatigue failure. We propose a method to prevent failure of the fixing bolt of the MEWP from four different standpoints: the manufacturer, safety certification authority, safety inspection agency, and owner.

ON THE FIXING NUMBER OF FUNCTIGRAPHS

  • Fazil, Muhammad;Javaid, Imran;Murtaza, Muhammad
    • 대한수학회보
    • /
    • 제58권1호
    • /
    • pp.171-181
    • /
    • 2021
  • The fixing number of a graph G is the smallest order of a subset S of its vertex set V (G) such that the stabilizer of S in G, ��S(G) is trivial. Let G1 and G2 be the disjoint copies of a graph G, and let g : V (G1) → V (G2) be a function. A functigraph FG consists of the vertex set V (G1) ∪ V (G2) and the edge set E(G1) ∪ E(G2) ∪ {uv : v = g(u)}. In this paper, we study the behavior of fixing number in passing from G to FG and find its sharp lower and upper bounds. We also study the fixing number of functigraphs of some well known families of graphs like complete graphs, trees and join graphs.

A COMPARATIVE STUDY ON THE DISLODGING FORCE OF MAGNETIC ATTACHMENT TO THE DENTURE RESIN BY MAGNETIC DESIGN AND FIXING MATERIALS

  • Lee, Jung-Hwa;Lee, Jong-Hyuk;Cho, In-Ho
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.261-268
    • /
    • 2008
  • STATEMENT OF PROBLEM: Detachment of the magnetic assembly from the denture base has been a problem in magnetic overdenture patients. PURPOSE: The objectives of this study were to compare the dislodging force by the fixing materials and the designs of the magnetic assembly, and to compare the effect between the fixing materials and the designs of the magnetic assembly. MATERIAL AND METHODS: Two fixing materials, Jet denture repair $acrylic^{(R)}$ and Super-$Bond^{(R)}$ C&$B^{(R)}$ and two types of magnetic assembly designed with or without wing were used. Each magnetic assembly was fixed in the chamber of the denture base resin block ($Lucitone^{(R)}$199) with each fixing material respectively. These specimens were thermocycled 2,000 cycles in the water held at $4^{\circ}C$ and $60^{\circ}C$ with a dwell time of 1 min each time. Each specimen was seated in a testing jig and then a push-out test was performed with a universal testing machine at a cross head speed of 0.5 mm/min to measure the maximum dislodging forces. RESULTS: Comparing the fixing materials, Super-Bond C&$B^{(R)}$ showed superior dislodging force than Jet denture repair $acrylic^{(R)}$. Comparing the design of the magnetic assemblies, the wing design magnetic assembly showed better dislodging force. Combination of the Super-Bond C&$B^{(R)}$ as a fixing material and wing design magnetic assembly revealed a greatest dislodging force. The kind of fixing material was more influential than the type of magnetic assembly. CONCLUSION: The dislodging force of Super-Bond C&$B^{(R)}$ was significantly higher than Jet denture repair $acrylic^{(R)}$. And the dislodging force of magnetic assembly which have wing design was significantly higher than magnetic assembly which have no wing design.

습지에서 분리한 질소고정 세균인 Mycobacterium hominis sp. AKC-10의 특성 (Characterization of a Nitrogen Fixing Bacteria Mycobacterium hominis sp. AKC-10 Isolated from the Wetland)

  • 홍선화;신기철;이은영
    • 한국미생물·생명공학회지
    • /
    • 제38권3호
    • /
    • pp.302-307
    • /
    • 2010
  • Nitrogen is an element need to grow plants growth. Plants take up nitrogen in the form of nitrate or ammonium. Most of plants absorb nitrogen source as fertilizers. But from 50 to 70% of fertilizers applied were washed away. This study was conducted to isolate free-living nitrogen fixing bacteria from reed and to examine its beneficial traits for developing sustainable biofertilizers. Enriched consortium obtained from a reed in Ansan was developed for the fixing of nitrogen. Nitrogen fixing bacteria isolated from an enriched culture in Congo Red Medium was analyzed by 16s rDNA sequencing. AKC-10 was isolated and shown to have excellent nitrogen fixing ability. The optimum conditions of nitrogen fixing ability were $25^{\circ}C$ ($237.50{\pm}39.65\;nmole{\cdot}mg-protein^{-1}{\cdot}h^{-1}$ and pH 7 ($168.335{\pm}12.84$ nmole/hr mg-protein). It was identified as Microbacterium hominis [(AKC-10 (similarity : 99%)]. This strain was had to IAA (indole-3-acetic acid) productivity and ACC(1-aminocyclopropane-1-carboxylic acid) deaminase activity. Therefore, Microbacterium hominis AKC-10 stimulated plant development in the soil, enhancing the efficiency of remediation.

고소작업대의 파손된 고정볼트의 피로분석에 관한 연구 (A Fatigue Analysis Study on the Fractured Fixing Bolts of Mobile Elevated Work Platforms)

  • 최동훈;김재훈
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.1-6
    • /
    • 2019
  • The mobile elevated work platforms(MEWPs) consist of work platform, extending structure, and car, and it is a facility to move persons to working positions. MEWPs are useful but composed complex pieces of equipments, and accidents are caused by equipment defects. Among them, accidents caused by fracture of the bolts fixing the extension structure and the turntable are increasing. In this study, fatigue failure and fatigue life of a turntable fixing bolt subjected to irregular fatigue load were analyzed by FEA. For this purpose, finite element modeling is proposed and structural analysis and fatigue analysis are performed simultaneously for fixing bolts. As a result of the structural analysis, it was confirmed that there is no risk of permanent deformation because the maximum stress acting on the fixing bolt is lower than the yield strength, and fatigue analysis was confirmed that the fatigue life is less than the design standard. The fatigue analysis results of this study can be effectively used for the design and the documentary assessment of the safety certification of the MEWPs by examining the fatigue life of the turntable fixing bolt.

PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구 (A Study on Reduction Effect of Processing Wastewater by Introduction of PACS)

  • 고신관;한동균;김욱동;강병삼;양한준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권2호
    • /
    • pp.167-175
    • /
    • 2007
  • 2001년부터 본격적으로 보급되기 시작한 PACS 도입은 영상의학과에서는 필름비용 절감, 인건비 절감, 현상액 사용량 절감, 관리업무 축소, 재 촬영 건수의 감소 등의 효과를 볼 수 있었고, 임상 의사들에게는 의료영상동시 활용, 임상정보의 증대, 진료 환자수의 증가, 의료영상 및 판독결과 활용성 증대 효과를 기대할 수 있는 것으로 알려져 있다. 환자들에게는 방사선 피폭선량 감소, 진료비 절감, 임상정보를 신속하게 알 수 있는 효과가 있다. 이에 본 저자들은 Full PACS를 도입한 서울 및 경기도의 10개 종합병원을 대상으로 하여 PACS로 인한 긍정적인 여러가지 효과 중 현상, 정착 폐수의 감소 추이를 알아보기 위하여 도입 1년 전과 도입 3년 후를 비교 분석하여 다음과 같은 결론을 얻었다. 1. 1개월 당 검사 건수는 7357.7건이 증가하였으나 필름 사용량은 90%가 감소하였다. 2. 현상액 월 평균 소모량은 3년 후 92%가 감소하였고, 정착액은 86%가 감소하였다. 3. 필름 1장 당월 평균 현상액 소모량은 3년 후 149%가 증가하였고, 정착액은 300%가 증가하였다. 4. 현상 폐수 발생량은 3년 후 월 평균 88%가 감소하였고, 정착 폐수는 87%가 감소하였다. 5. 3년 후 필름 1장 당월 평균 현상폐수 발생량은 377%, 정착폐수 발생량은 385%가 증가하였다.

  • PDF