• 제목/요약/키워드: fixed plate

검색결과 487건 처리시간 0.023초

평균년 표준기상데이터를 이용한 평판형 태양열 집열기 설치각 산정에 관한 연구 (A Study on the Setting Angle for the Flat-Plate Solar Collector' using Typical Meteorological Year Weather Data)

  • 최정민
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1084-1091
    • /
    • 2002
  • In general, flat-plate solar collectors are generally fixed in place at some angles. The most common method is to orient solar collectors toward the true south, where variations up to 15 degrees east or west are acceptable and the tiIt angle of the collectors is calculated from latitude and different heating applications. However, the best angle of flat-plate collectors depends upon whether the dominant load occurs in the winter, summer, or evenly all year. Moreover, this setting angle must consider the average insolation characteristics of the region exactly. In this study, the setting angle of flat-plate solar collectors is presented for Busan area by using domestic typical meteorological year weather data, so that the fixed flat-plate solar collectors must be set as quantitatively as possible.

임프란트를 이용한 고정성 계속가공의치의 FRAMEWORK 형태에 관한 연구 (A SUTDY ABOUT THE SHAPE OF THE FRAMEWORK OF THE FIXED BONE ANCHORED BRIDGE USING DENIAL IMPLANTS)

  • 김태균;이영수;유광희
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.104-119
    • /
    • 1998
  • The purpose of this study was pertinent design of the framework of the fixed bone anchored bridge using implants in the edentulous mandible through analysis of stress distribution by the three dimensional finite element analysis method. The results were as follows: 1. The L-shaped framework was favorable in restoring the edentulous mandible by implants and fixed bone anchored bridge. 2. The structure of the framework should be designed to endure the occlusal load because of stress concentration at the most distal abutment of the framework. 3. The stress at the distal implant where cantilever starts was twice as much as that of other portions. 4. Compressive stress was generated on the framework of the mesial side of the distal implant and extrusive force was induced to the mesially positioned implants. 5. The height of vertical plate was high as possible as can be to distribute stresses concentrating bucco-lingually and labio-lingually in the framework between abutments, 6. Reinforcement of the horizontal plate thickness was needed because stress was loaded more on the horizontal plate than on the vertical plate of the framework. 7. Lengthening of the vertical plate can compensate for any limitations in horizontal plate width.

  • PDF

제진 강판의 블랭킹 가공 특성에 관한 연구 (A Study on the Blanking Characteristic of Anti- Vibration Sheet Metal)

  • 이광복;이용길;김종호
    • 소성∙가공
    • /
    • 제12권8호
    • /
    • pp.724-729
    • /
    • 2003
  • In order to study the shearing characteristic of anti-vibration sheet metal which is used to reduce vibration noise, a blanking die was manufactured to blank a workpiece. The variables employed in this study were clearance, type of stripper plate, position of the rubber layer and type of the die design. These variables were used to study the effects on burr height, blank diameter and camber height. In the case of burr height from experimental investigation, the push-back die, combined with a movable stripper plate, showed greater burr height. The rubber-top position of a workpiece resulted in better qualities regardless of working variables. In the comparison of diameter measurement, the use of the push-back die with a fixed stripper plate, with a 4.5% clearance, showed better accuracy. For comparing camber height, the push-back die resulted in less cambering than the drop-through die. Also, the larger the clearance, the greater was the camber height. Considering experimental results, the shearing of anti-vibrational sheet metal is best achieved when the rubber layer is laying on the top, blanked with a fixed stripper plate in a push-back die, with a 4.5% clearance.

프레스에 의한 블랭킹 판재의 응력 해석 (Stress Analysis of Blanking Plate Applied by Press)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제7권2호
    • /
    • pp.66-71
    • /
    • 2008
  • The data of the deformation and the stress according to time are studied at upper model of press and lower model of the blanking plate applied by press with the width, length and height of 0.4 m and 0.6 m respectively. The press is pushing downward on the plate fixed at the lower floor. These data are compared and investigated through this study. By using these results, there is the maximum deformation at 4 corners in the lower plate model of aluminium alloy fixed at lower floor. This deformation incase of elapsed time of 0.6 second becomes 4 times as much as in case of elapsed time of 0.2 second. The quantity of deformation at the lower plate model becomes more than at the upper press model to the extent of 10%. At the lower plate model of aluminium alloy, there is the maximum Von-Mises equivalent stress at 4 corners and both sides of middle area on the lower plate model of aluminium alloy. This stress in case of elapsed time of 0.6 second becomes 6 times as much as in case of elapsed time of 0.2 second. The Von-Mises equivalent stress of lower plate model becomes 2 times as much as that of upper press mode.

  • PDF

Early Stage of Algal Succession on Artificial Reefs at Muronohana, Ikata, Japan

  • Choi Chang Geun;Takayama Hiroshi;Segawa Shigeru;Ohno Masao;Sohn Chul Hyun
    • Fisheries and Aquatic Sciences
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 2000
  • Different substrata fixed as the roof (for shadow) on artificial iron reef had been developed as a tool for valuable fishery resources. The experiment was set up on a sandy bottom substratum at 8m depth in Muronohana, Ikata, Japan. Within one month of placement of the plates, diatoms dominated the experimental plates with a coverage of $100\%$ approximately. Enteromorpha intestinalis and Colpomenia sinuosa dominated within three months after the placement. E. intestinalis coverage on substrata was estimated $7\%$ on the plate shaped iron bar, $12-14\%$ on concrete plates, $18\%$ on the plate fixed pebble, $61\%$ on the plate to accumulated wood, and 80-100% on the steel materials plate. Whereas after four months of placement, C. sinuosa coverage on plates became $1-36\%$ on different plates, and $100\%$ on the plate to accumulated wood. The differences in E. intestinalis and C. sinuosa colonization on the different substrata were probably due to variations in their surface roughness influencing the settlement of zoospores, and thus gametophyte. development. After five months of placement, the above two species slowly disappeared.

  • PDF

외륜 고정형 에피 사이클로이드 감속기의 작용력 해석법에 관한 연구 (A Study on Contact Force Analysis of Fixed Outer-Ring Type Epicycloid Plate Gear for Cycloidal Speed Reducer with Friction Effect)

  • 장세원;홍진표;신중호;권순만
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1652-1655
    • /
    • 2005
  • All teeth on the cycloidal plate gear exist in the contact motion with rollers and the forces are interacted between roller gears with cycloidal plate gears. So, the contact forces and friction forces must be required to improve the accuracy in design procedures of cycloidal speed reducers. This paper presents a force analysis considered the friction effect approach derived by static force equilibrium condition, geometrical adaptation, instant velocity center method and relative velocity method. Finally, the paper develops CAD-program for the construction of the design automation using the proposed method.

  • PDF

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.

모우드 해석법에 의한 CFRP PLATE의 동특성에 관한 연구 (A study on the dynamic characteristics of CFRP PLATE by modal analysis method)

  • 한응교;오재응;방태규
    • 오토저널
    • /
    • 제11권1호
    • /
    • pp.44-50
    • /
    • 1989
  • 본 논문에서는 모우드 해석법(Modal Analysis Method)을 이용하여 종래 재료에 비해 우 수한 기계적 성질을 갖는 복합재료에 대하여 동특성을 규명하고자 하였다. 재료로는 알루미늄 판(AL PLATE)과 탄소섬유강화 복합적층판(CFRP)을 비교하였으며, 그 결과 전체적인 진동레 벨이 AL PLATE 보다 CFRP PLATE가 낮았고 섬유방향이 고정단고 직각인 경우보다 평행인 경우가 낮음을 알았다. 또한 AL PLATE와 유사한 진동형을 나타내는 CFRP PLATE의 고유 진동모우드가 저주파수쪽으로 이동함을 알 수 있었다.

  • PDF