배전선로에 유도발전기 연결시 역률 변동에 관한 연구 (A Study on the Variation of Power Factor by Connection of the Induction Generator to the Distribution Line)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제64권3호
    • /
    • pp.159-163
    • /
    • 2015
  • Recently squirrel cage induction generator has been steadily applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed that how the increase or decrease of D/L load impacts at the change of power factor and power flow.

Single-Stage High-Power-Factor Electronic Ballast with a Symmetrical Class-DE Resonant Rectifier

  • Ekkaravarodome, Chainarin;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.429-438
    • /
    • 2012
  • This paper presents the use of a novel, single-stage high-power-factor electronic ballast with a symmetrical class-DE low-$d{\upsilon}$/$dt$ resonant rectifier as a power-factor corrector for fluorescent lamps. The power-factor correction is achieved by using a bridge rectifier to utilize the function of a symmetrical class-DE resonant rectifier. By employing this topology, the peak and ripple values of the input current are reduced, allowing for a reduced filter inductor volume of the EMI filter. Since the conduction angle of the bridge rectifier diode current was increased, a low-line current harmonic and a power factor near unity can be obtained. A prototype ballast, operating at an 84-kHz fixed frequency and a 220-$V_{rms}$, 50-Hz line input voltage, was utilized to drive a T8-36W fluorescent lamp. Experimental results are presented which verify the theoretical analysis.

고정된 핀 바닥 높이에 기준한 기하학적 비대칭 사다리꼴 핀의 최적 설계 (Optimum Design of a Geometrically Asymmetric Trapezoidal Fin Based on the Fixed Fin Base Height)

  • 강형석
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.81-87
    • /
    • 2008
  • A geometrically asymmetric trapezoidal fin with variable fin base thickness and height is optimized based on the fixed fin base height using a one-dimensional analytic method. The temperature profile along the normalized X position in the fin is presented. For the fixed fin base height, the optimum heat loss, fin length and efficiency as a function of inside fluid convection characteristic number, fin base thickness and height, fin shape factor, convection characteristic numbers ratio and ambient convection characteristic number are represented. One of the results shows that the effect of fin base height and ambient convection characteristic number on the optimum values is remarkable.

LED 정전류 구동회로의 입력전압 리플 크기에 의한 특성 비교 (Characteristic comparisons of the constant current LED driver by the ripple of the input voltage)

  • 박종연;전인웅;유진완;최영민
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.115-118
    • /
    • 2012
  • Recently, there are a lot of papers in order to replace the electrolytic capacitor into the film capacitor in output of PFC(Power Factor Correction). However, the film capacitor, which has capacitance of low values, causes a large ripple voltage in output of PFC. The LED drivers are connected series in the output of PFC and affected by the magnitude of voltage ripple. In this paper, we have compared the fixed frequency method with the variable frequency for the constant-current control and propose the control method to avoid the sub-harmonic oscillation in the variable input voltage. An 80W PFC, using film capacitors instead of electrolytic capacitors, and LED driver has been built and compared the fixed frequency control method with the variable frequency control method.

  • PDF

레진시멘트와 보철재료와의 접착 (Luting between Resin Cement and Dental Prosthetic Materials)

  • 김광만
    • 대한치과의사협회지
    • /
    • 제53권3호
    • /
    • pp.195-200
    • /
    • 2015
  • Cementation is the last procedure and an important factor to access successful fixed prosthodontic treatment. Even though there are many kinds of luting materials in dental field, the resin cements are popularly used in now. Metals, polymers and ceramics are used as a material of fixed dental prosthesis. The bonding mechanisms between teeth and fixed restorations are composed of mechanical and chemical mechanism. In dentistry, we are relying on mechanical bonding, but we tried to get chemical bonding and many ways are introduced. So, we have to approach luting procedure differently by the materials of prosthesis for clinical success. In this article, let us think the proper cementation ways according to each prosthesis material.

Soil structure interaction effects on strength reduction factors

  • Eser, Muberra;Aydemir, Cem;Ekiz, Lbrahim
    • Structural Engineering and Mechanics
    • /
    • 제41권3호
    • /
    • pp.365-378
    • /
    • 2012
  • In this study, strength reduction factors are investigated for SDOF systems with period range of 0.1-3.0 s with elastoplastic behavior considering soil structure interaction for 64 different earthquake motions recorded on different site conditions such as rock, stiff soil, soft soil and very soft soil. Soil structure interacting systems are modeled and analyzed with effective period, effective damping and effective ductility values differing from fixed-base case. For inelastic time history analyses, Newmark method for step by step time integration was adapted in an in-house computer program. Results are compared with those calculated for fixed-base case. A new equation is proposed for strength reduction factor of interacting system as a function of structural period of system (T), ductility ratio (${\mu}$) and period lengthening ratio (T/T). It is concluded that soil structure interaction reduces the strength reduction factors for soft soils, therefore, using the fixed-base strength reduction factors for interacting systems lead to non-conservative design forces.

감진계통 지지부가 설치된 기기의 지진해석 (Seismic Response Analysis of Support-Isolated Equipment in Primary Structure)

  • 김영상;이동근
    • 대한토목학회논문집
    • /
    • 제12권2호
    • /
    • pp.35-42
    • /
    • 1992
  • 본 논문에서는 주 구조물 내에 설치된 기기의 지지점에 감진계통을 도입함으로써 지진하중에 대한 기기의 응답감소효과를 연구하였으며, 효율적인 해석을 수행하기 위해 구조물-기기 상호작용 고려 및 축소 행렬방법을 이용한 전산프로그램(KBISAP)을 개발하였다. 지지점에 감전장치가 설치된 기기의 지진하중에 대한 응답감소 효율성을 평가하기 위해 세가지 해석모델, 즉 고정기초구조물 상의 지지점이 고정된 기기, 감진기초구조물 상의 지지점이 고정된 기기 및 고정기초구조물 상의 지지점에 감진계통이 설치된 기기를 채택한 예제해석 결과, 본 논문에서 채택한 방법이 일반적인 고정기초구조물은 물론 감진기초구조물 상에 설치된 기기의 지진하중에 대한 응답감소 보다 더 효율적임을 알 수 있었다. 따라서 본 방법은 기기의 응답감소는 물론 중요한 기기의 안전성 향상에 효과적이다.

  • PDF

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

배전선로에 유도발전기 연결시 역률 변동에 관한 연구 (A study on the variation of power factor by connection of the induction generator to the distribution line)

  • 김종겸;박영진;이경배;김영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1469-1470
    • /
    • 2015
  • Recently induction generator has been applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed how the power factor is changed according to the load increase or decrease in the distribution lines.

  • PDF

패턴드 그라운드 쉴드를 적용한 나선형 인덕터 특성 연구 (A Study on Characteristic of Spiral Inductor with Patterned Ground Shield)

  • 고재형;김형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.272-273
    • /
    • 2007
  • This paper presents the characteristic of rectangular and octagonal spiral inductor using PGS(Patterned Ground Shield). We investigated variation of inductance and Q-factor with changing of turn number at fixed width, spacing and inner diameter. We confirmed that characteristic of inductance and Q-factor be appled PGS in rectangular and octagonal types spiral inductor by EM simulation tool. Inductance decreased irrespective of structure but Q-factor increased. When PGS not exist, Q-factor of Inductor is analogous at classification frequency but, rectangular is a few larger then octagonal in small turn number. The other side, When PGS is inserted, we confirmed that octagonal lager then rectangular in many turn number. Q-factor is improved in case of octagonal structure and small turn number by PGS effect.

  • PDF