• Title/Summary/Keyword: fixed bias

Search Result 199, Processing Time 0.027 seconds

Outcomes of comprehensive fixed appliance orthodontic treatment: A systematic review with meta-analysis and methodological overview

  • Papageorgiou, Spyridon N.;Hochli, Damian;Eliades, Theodore
    • The korean journal of orthodontics
    • /
    • v.47 no.6
    • /
    • pp.401-413
    • /
    • 2017
  • Objective: The aim of this systematic review was to assess the occlusal outcome and duration of fixed orthodontic therapy from clinical trials in humans with the Objective Grading System (OGS) proposed by the American Board of Orthodontics. Methods: Nine databases were searched up to October 2016 for prospective/retrospective clinical trials assessing the outcomes of orthodontic therapy with fixed appliances. After duplicate study selection, data extraction, and risk of bias assessment according to the Cochrane guidelines, random-effects meta-analyses of the mean OGS score and treatment duration were performed and 95% confidence intervals (CIs) were calculated. Results: A total of 34 relevant clinical trials including 6,207 patients (40% male, 60% female; average age, 18.4 years) were identified. The average OGS score after treatment was 27.9 points (95% CI, 25.3-30.6 points), while the average treatment duration was 24.9 months (95% CI, 24.6-25.1 months). There was no significant association between occlusal outcome and treatment duration, while considerable heterogeneity was identified. In addition, orthodontic treatment involving extraction of four premolars appeared to have an important effect on both outcomes and duration of treatment. Finally, only 10 (39%) of the identified studies matched compared groups by initial malocclusion severity, although meta-epidemiological evidence suggested that matching may have significantly influenced their results. Conclusions: The findings from this systematic review suggest that the occlusal outcomes of fixed appliance treatment vary considerably, with no significant association between treatment outcomes and duration. Prospective matched clinical studies that use the OGS tool are needed to compare the effectiveness of orthodontic appliances.

Frequency Adjustable Dual Composite Right/Left Handed Transmission Lines (주파수 가변성을 갖는 D-CRLH 전송 선로)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1375-1382
    • /
    • 2008
  • Frequency adjustable D-CRLH(dual-composite right/left handed) transmission lines, which solve the problem of design complexity and uncontrolled frequency of the existing structures, are proposed in this paper. The first design(type I), consisting of defected ground structure(DGS), island pattern in DGS, fixed stub and varactor diodes, controls $C_L$ in the parallel resonant circuit, while the second structure(type 2) composed of fixed DGS, shunt stub and diode adjusts $C_R$ in the series resonant circuit. The dual band frequency points which correspond to the meaningful electrical length of +/-90 degree in the RH/LH region are adjustable according to the bias voltage. The measurement shows that the LH frequency point which has -90 degree of electrical length are adjusted over $4.22{\sim}5.39\;GHz$ and $4.21{\sim}5.05\;GHz$ for type 1 and type 2, respectively, under $1{\sim}12\;V$ of bias voltage. In addition, the frequency Woo where RH turns over LH is controled over $3.26{\sim}4.22\;GHz$ for type 2 with the same bias condition.

Nearest-neighbor Rule based Prototype Selection Method and Performance Evaluation using Bias-Variance Analysis (최근접 이웃 규칙 기반 프로토타입 선택과 편의-분산을 이용한 성능 평가)

  • Shim, Se-Yong;Hwang, Doo-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.10
    • /
    • pp.73-81
    • /
    • 2015
  • The paper proposes a prototype selection method and evaluates the generalization performance of standard algorithms and prototype based classification learning. The proposed prototype classifier defines multidimensional spheres with variable radii within class areas and generates a small set of training data. The nearest-neighbor classifier uses the new training set for predicting the class of test data. By decomposing bias and variance of the mean expected error value, we compare the generalization errors of k-nearest neighbor, Bayesian classifier, prototype selection using fixed radius and the proposed prototype selection method. In experiments, the bias-variance changing trends of the proposed prototype classifier are similar to those of nearest neighbor classifiers with all training data and the prototype selection rates are under 27.0% on average.

Generalized Composite Estimators and Mean Squared Errors for l/G Rotation Design (l/G 교체표본디자인에서의 일반화복합추정량과 평균제곱오차에 관한 연구)

  • 김기환;박유성;남궁재은
    • The Korean Journal of Applied Statistics
    • /
    • v.17 no.1
    • /
    • pp.61-73
    • /
    • 2004
  • Rotation sampling designs may be classified into two categories. The first type uses the same sample unit for the entire life of the survey. The second type uses the sample unit only for a fixed number of times. In both type of designs, the entire sample is partitioned into a finite number(=G) of rotation groups. This paper is generalization of the first type designs. Since the generalized design can be identified by only G rotation groups and recall level 1, we denote this rotation system as l/G rotation design. Under l/G rotation design, variance and mean squared error (MSE) of generalized composite estimator are derived, incorporating two type of biases and exponentially decaying correlation pattern. Compromising MSE's of some selected l/G designs, we investigate design efficiency, design gap effect, ans the effects of correlation and bias.

Research on the Actual Condition of Shape and Make-up of Peanut-Shaped Cloth Diaper for Baby on Market (시판중인 유아용 땅콩기저귀의 형태와 구성에 관한 실태조사)

  • Lee, Jung-Soon;Han, Gyung-Hee;Koo, Mi-Ran
    • Journal of Fashion Business
    • /
    • v.15 no.4
    • /
    • pp.122-134
    • /
    • 2011
  • The peanut-shaped cloth diaper has cut uncomfortable crotch region off the square-shaped cloth diaper into a peanut-shape, and finished the edge by bias with multi-layers of fabric. This study has the purpose on providing the basic data for designing the peanut-shaped cloth diaper. For this purpose, the peanut-shaped cloth diapers on market were collected and analyzed by their shape and size, and also the patterns and differences in making were compared. 26 products from 17 brands were collected as samples. The analysis factors are the shape and size of the peanut-shaped cloth diaper, and characteristics and patterns in making. Among the samples, only 3 diapers were straight-shaped; the rest of them were peanut-shaped. The size difference between the big and small peanut-shaped cloth diapers was very large; the total length of the small one was 36.5cm-39cm which was very common, and the total length of the big one was more than 44cm. All diapers had longer width in the back than the front. The width of the front and back was different for each sample, therefore, it seemed to have some difficulties to set the standard. The peanut-shaped cloth diaper had different make-up depending on its characteristics including. absorbance, washing and drying. It was usually made by cotton woven of diamond jacquard or knit, and finished the edge by woven bias or knit bias. The peanut-shaped cloth diapers were various including a sheet of diaper, two sheets of diapers fixed with velcro, three sheets of diapers, and etc. For the patterns of the diapers, only two samples out of all had three dimensional shape, and the rest were produced using flat shape. There were no distinction between the diapers of girls and boys. Therefore, it is necessary to make the product based on scientific data about the peanut-shaped cloth diaper.

Bias-enhanced Nucleation of Diamond in Hot Filament CVD (열필라멘트 CVD에서 전압 인가에 의한 다이아몬드의 핵생성 촉진)

  • Choi, Kyoon;Kang, Suk-Joong L.;Hwang, Nong-M.
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.6
    • /
    • pp.636-644
    • /
    • 1997
  • The effect of various processing parameters, in particular the substrate and filament temperature, on the nucleation of diamond has been studied for the hot filament CVD process with a negative bias on the substrate. As far as the substrate temperature was maintained around the critical temperature of 73$0^{\circ}C$, the nucleation of diamond increased with increasing filament temperature. The maximum nucleation density of ~ 2$\times$109/$\textrm{cm}^2$ was obtained under the condition of filament temperature of 230$0^{\circ}C$, substrate temperature of 75$0^{\circ}C$, bias voltage of 300V, methane concentration of 20%, and deposition time of 2 hours. This nucleation density is about the same as those obtained in previous investigations. For fixed substrate temperatures, the nucleation density varies up to about 103 times depending on experimental conditions. This result is different from that of Reinke, et al. When the substrate temperature was above 80$0^{\circ}C$, a silkworm~shaped carbon phase was co-deposited with hemispherical microcrystalline diamond, and its amount increased with increasing substrate temperature. The Raman spectrum of the silkworm-shaped carbon was the same as that of graphitic soot. The silkworm-shaped carbon was etched and disappeared under the same as that of graphitic soot. The silkworm-shaped carbon was etched and disappeared under the deposition condition of diamond, implying that it did not affect the nucleation of diamond.

  • PDF

Angular Dependence of Exchange Bias in NiFe/MnIr Bilayers (NiFe/MnIr 박막에서 교환 바이어스의 각도 의존성 연구)

  • Yoon, Seok Soo;Kim, Dong Young
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.1
    • /
    • pp.30-34
    • /
    • 2017
  • In this report, we calculated the angular dependence of exchange bias ($H_{ex}$) by using single domain model in exchange coupled ferromagnetic (F)/antiferromagnetic (AF) bilayers, which results with AF thickness ($t_{AF}$) were used for the analysis of measured ones in NiFe/MnIr bilayers. Angular dependence of $H_{ex}$ calculated at $t_{AF}$ > $t_c$ showed typical unidirectional behaviors, however, calculated one at $0.5t_c$ < $t_{AF}$ < $t_c$ showed peculiar angular behaviors by fixed AF spins at specified angle near ${\theta}_H=90^{\circ}$. Angular dependence of $H_{ex}$ measured in NiFe/MnIr (20 nm) bilayers showed typical unidirectional behaviors. However, measured one in NiFe/MnIr (4 nm) bilayers showed mixed behaviors including both of unidirectional and peculiar angular behaviors, which was explained by the grain size distribution of polycrystalline MnIr.

Weighting Effect on the Weighted Mean in Finite Population (유한모집단에서 가중평균에 포함된 가중치의 효과)

  • Kim, Kyu-Seong
    • Survey Research
    • /
    • v.7 no.2
    • /
    • pp.53-69
    • /
    • 2006
  • Weights can be made and imposed in both sample design stage and analysis stage in a sample survey. While in design stage weights are related with sample data acquisition quantities such as sample selection probability and response rate, in analysis stage weights are connected with external quantities, for instance population quantities and some auxiliary information. The final weight is the product of all weights in both stage. In the present paper, we focus on the weight in analysis stage and investigate the effect of such weights imposed on the weighted mean when estimating the population mean. We consider a finite population with a pair of fixed survey value and weight in each unit, and suppose equal selection probability designs. Under the condition we derive the formulas of the bias as well as mean square error of the weighted mean and show that the weighted mean is biased and the direction and amount of the bias can be explained by the correlation between survey variate and weight: if the correlation coefficient is positive, then the weighted mein over-estimates the population mean, on the other hand, if negative, then under-estimates. Also the magnitude of bias is getting larger when the correlation coefficient is getting greater. In addition to theoretical derivation about the weighted mean, we conduct a simulation study to show quantities of the bias and mean square errors numerically. In the simulation, nine weights having correlation coefficient with survey variate from -0.2 to 0.6 are generated and four sample sizes from 100 to 400 are considered and then biases and mean square errors are calculated in each case. As a result, in the case or 400 sample size and 0.55 correlation coefficient, the amount or squared bias of the weighted mean occupies up to 82% among mean square error, which says the weighted mean might be biased very seriously in some cases.

  • PDF

Etching Characteristics of Au Thin Films using Inductively Coupled CF4 / Cl2 / Ar Plasma

  • Kim Dong-Pyo;Kim Chang-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.3
    • /
    • pp.1-4
    • /
    • 2003
  • The etching of Au thin films has been performed in an inductively coupled $CF_4 / Cl_2 / Ar$ plasma. The etch properties including etch rate and selectivity were examined as $CF_4$ content adds from o to $30\%$ to $Cl_2/Ar$ plasma. The $Cl_2/(Cl_2 + Ar)$ gas mixing ratio was fixed at $20\%$. Other parameters were fixed at an rf power of 700 W, a dc bias voltage of -150 V, a chamber pressure of 15 mTorr, and a substrate temperature of $30^{\circ}C$. The highest etch rate of the Au thin film was 370 nm/min at a $10\%$ additive $CF_4$ into $Cl_2/Ar$ gas mixture. The surface reaction of the etched Au thin films was investigated using x-ray photoelectron spectroscopy (XPS) analysis. The XPS analysis shows that the intensities of Ail peaks are changed, indicating that there is a chemical reaction between Cl and Au. Au-Cl is hard to remove on the surface because of its high melting point. However, etching products can be sputtered by Ar ion bombardment.

Etching Characteristics of Gold Thin Films using Inductively Coupled CF4/CI2/Ar Plasma (CF4/CI2/Ar유도 결합 플라즈마에 의한 gold 박막의 식각특성)

  • 김창일;장윤성;김동표;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.564-568
    • /
    • 2003
  • The etching of Au thin films have been performed in an inductively coupled CF$_4$/Cl$_2$/Ar plasma. The etch rates were measured as CF$_4$ contents added from 0 to 30 % to Cl$_2$/Ar plasma, of which gas mixing ratio was fixed at 20%. Other parameters were fixed at an rf power of 700 W, a dc bias voltage of 150 V, a chamber pressure of 15 mTorr, and a substrate temperature of 3$0^{\circ}C$. The highest etch rate of the Au thin film was 3700 $\AA$m/min at a 10% additive CF$_4$ into Cl$_2$/Ar plasma. The surface reaction of the etched Au thin films was investigated using x-ray photoelectron spectroscopy (XPS) analysis. XPS analysis indicated that Au reacted with Cl and formed Au-Cl, which is hard to remove on the surface because of its high melting point. The etching products could be sputtered by Ar ion bombardment.