• Title/Summary/Keyword: fixation order

Search Result 217, Processing Time 0.031 seconds

Chemical Fixation and Sorption of Bentonite for the Removal of Heavy Metals in Acid Mine Drainage (AMD) (광산산성폐수에 함유된 중금속 처리를 위한 Chemical Fixation과 Bentonite의 흡착)

  • Jang, Am;Kim, In-S.
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.2
    • /
    • pp.33-43
    • /
    • 2000
  • Mining wastes left without any proper treatment are affecting barren or arable lands where are located near and far from source through various pathway Metals are the only hazardous constituents that cannot be destroyed or altered by chemical or thermal methods and must be converted into the most insoluble and harmless form as possible, which have slower leaching rates than the original species, to prevent their reentry into the environment. Three types of chemical additives used in this study to immobilize heavy metals showed high immobilized capacity (q) and the efficiency (k) in the order of CaO, $Na_2$S.$5H_2$O, and $CaCO_3$. In addition, bentonite was considered as a good additive to remedy AM(Acid Mine Drainage) from the results of the physicochemical characteristics and immobilizing capacity. The Freundlich coefficients (n and k) from adsorption isotherm for the heavy metals adsorbed on 50g Benlonite were calculated.

  • PDF

2D Lower Body Flat Pattern of the Women in Their Twenties Using 3D Scan Data (3차원 인체 형상을 이용한 20대 여성의 하반신 전개패턴에 관한 연구)

  • Yoon, Mi-Kyung;Nam, Yun-Ja;Choi, Kyeng-Mi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.5 s.164
    • /
    • pp.692-704
    • /
    • 2007
  • Recently, Basic patterns with excellent body fitness and automation availability are required to be developed in order to automate the patterns of women's clothes. In this study, this reference points, reference lines and segments were fixed onto 3D scan data for the lower body the women in their twenties, they were directly spread out to be 2D flat pattern to facilitate development into the design of slacks adhered closely to the human body such as special and highly-functional clothes, and then slacks 2D pattern was developed for the purpose of seeking scientific approach to the development into basic form slacks and 3d emotional pattern. For conversion of 3D pattern into 2D flat pattern, reference points and segments were created by using Rapid Form of 3D shape analysis software, and triangle mesh of the body surface of the created shape was developed with Auto CAD 2005. The correspondence between slacks and human body was examined by the fixation of major reference lines. Specially, the wearing characteristics of slacks were considered by the fixation of side lines in consideration of posture. As a result of using the way of development to constantly maintain the length while 3D triangle mesh is converted into 2D flat mesh, the shape was shown to be excellently reproduced, and the area of flat pattern was increased compared to the shape of parting plane. Also, the sunk-in curve like the brief line of front crotch length needed a cutting line when it was closely adhered, when mesh was overlapped, and the pattern area was smaller compared to the actual shape.

Inframammary Fold Creation in Breast Reconstruction (유방재건시 유방하 주름의 생성)

  • Lee, Hae Min;Ahn, Hee Chang;Choi, Seung Suk;Jo, Dong In;Byun, Tae Ho
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.231-236
    • /
    • 2005
  • Nowadays breast reconstruction with autologous tissues after radical mastectomy is commonly performed, and a natural inframammary fold in the reconstructed breast is considered to be an essential aspect of symmetrical breast shape and location. Total of 104 patients underwent breast reconstruction with free TRAM flap and formation of inframammary fold with free TRAM breast reconstruction was done in 79 patients. No suture fixation for inframammary fold were done in 19 patients. 27 patients(24.0%) were made of inframammary fold with absorbable suture, 52 patients (50.0%) underwent inframammary fold creation with nonabsorbable suture. There were 4 cases(16.0%) of displacement of reconstructed breast and 2 cases(8.0%) of partial disruption of inframammary fold in the group of no suture. There were 2 cases(7.4%) of displacement of reconstructed breast and 3 cases(11.1%) of partial disruption of inframmamary fold in the fixed group with absorbable suture. There was only 1 case(1.9%) of partial disruption of inframammary fold fixed with nonabsorbable suture group. Therefore, we could speculate that the reinforcement of ligamentous structure for making the definite inframammary fold is necessary, and the area of the inframammary fold should not be undermined in immediate breast reconstruction as much as possible in order to preserve the zone of adherence. If the fold is disrupted during the mastectomy, it should be re-created with the non-absorbable sutures. Nonabsorbable suture fixation seemed to be more stable than absorbable suture. Preoperative marking and design are very important to make the symmetrical shape and location of inframammary fold in both of immediate and delayed reconstruction of breasts.

Management of Unilateral Facet Dislocation of the Cervical Spine

  • Baek, Geum-Seong;Lee, Woo-Jong;Koh, Eun-Jeong;Choi, Ha-Young;Eun, Jong-Pil
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.295-300
    • /
    • 2007
  • Objective : Unilateral facet dislocation of the cervical spine occurs by flexion and rotation injuries and cannot be easily reduced by axial traction. We analyzed 14 consecutive patients with unilateral facet dislocation of the cervical spine to increase knowledge about anatomical reduction of locked facet and factors for successful reduction. Methods : Fourteen patients [10 men and 4 women] with unilateral facet dislocation of the cervical spine were retrospectively analyzed. Plain X-ray, computerized tomography scan, and magnetic resonance imaging were performed. All patients underwent manual reduction and surgery with anterior interbody fusion and plate fixation. The manual reduction was performed by neck flexion and rotation to the opposite side of dislocation, followed by rotation and flexion of the head toward the side of dislocation and extension with relaxation of traction. Mean follow-up period was 17 months. The level of spine, amount of subluxation, combined facet fracture, and time from injury to initial reduction were analyzed using the data obtained from medical records. Results : Thirteen [93%] patients were reduced successfully. Immediate reduction was achieved in 7 patients but failed in 7 patients. Seven patients underwent delayed closed reduction under general anesthesia, and successful reduction was achieved in 6 patients. Only one patient with bone chips between articular facets failed to achieve anatomical reduction. Conclusion : In order to reduce the locked facet more easily and safely, we recommend manipulative traction with anterior interbody fusion and plate fixation under general anesthesia after being aware of spinal cord injury with magnetic resonance imaging.

Fixation Method of Prestressed Fiber Optic Sensor (광섬유센서의 프리스트레인 부가 고정방식)

  • Kim, Ki-Soo
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.211-216
    • /
    • 2012
  • FBG sensor peaks could be split due to polarization by shear strain, when the fiber optic sensors embedded or attached to the structure. For the fiber optic sensor packages, sensor grating has to be protected from shear strains. Also, pretension has to be applied to the sensor because compressive strain must be measured. Without pretension of sensor, the sensor does not show any change of signal until it is stretched. In order to mesure compressive and tensile strains, two fixing point and prestressed sensor need. In the fixing point, just holding the optical fiber cause slip between core and cladding in the fiber. A Fixation method of prestressed FBG sensors fixed with partially stripped fibers was developed. The sensor package has the prestress controllable fixtures at the fixing points. Prestress to the sensor imposed by controlling the two fixed points with bolts and nuts make it easy to measure compressive strain as well as tensile strain. The fiber optic sensor packages applied to the actual structure and the structural monitoring system using the package can be applied to safety through surveillance.

A CLINICAL STUDY OF MOUTH OPENING RANGE IN MANDIBULAR CONDYLE FRACTURES (하악골 과두돌기 골절시 개구범위에 관한 임상적 연구)

  • Woo, Seung-Cheol;Um, In-Woong;Lee, Dong-Keun;Kim, Soo-Nam
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.4
    • /
    • pp.283-294
    • /
    • 1992
  • Functional recovery associated with mouth opening after mandibular condyle fracture was a contradictory result of many authors. The treatment goal of condyle fracture has been not only the good reduction and fixation but also the rapid functional recovery with mouth opening capacity. The purpose of this study is to evaluate the mouth opening capacity after surgical or non-surgical treatment of condyle fracture according to the site, level, maxillomandibular fixation(MMF) and operation method based on 39 patents with condyle fracture who were admitted to the department of oral and maxillofacial surgery, Wonkwang University Hospital from May.1, 1990 to Aug.31, 1992. The results were as follows. 1. The most common fracture site was level IV (17 cases : 42.2%) and level I (14 cases : 36.8%), level II (5 cases: 13.2%) and level III(3 cases : 7.9%) were in decreasing order of frequency. Compound fracture with symphysis was more frequent (69.2%) than simple fracture(30.8%). 2. The mouth opening capacity was increased in the level I compared with level IV. 3. The mouth opening capacity was increased in the group of segment removal. 4. The mouth opening capacity was increased in the MMF period was decreased. 5. Better mouth opening capacity was recorded in the physical therapy group of more than 3-4 weeks of treatment period.

  • PDF

The Effects of Eye Lateralization on Transient Evoked Otoacoustic Emissions of Auditory Function (측방 눈 주시가 유발이음향방사 청각기능에 미치는 영향)

  • Joo, Seokhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.131-140
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the interrelationship between eye movement and auditory function through the effects of eye lateralization on transient evoked otoacoustic emissions of auditory function. Methods : 25 subjects with complete set of ears were used in this study, which composed of 12 males and 13 females with pure tone threshold of below 25 dB without otolaryngology were evaluated. Each of the patient has a visual acuity of greater than 1.0 after correction, and has no problems with eye disease, eye movement, and human parallel system. In a dark silent room, the subjects sat on a chair with their heads fixed on a headrest. The tests were performed by asking the patients to look at a fixed red light dot on a light bar in front of them. This light was directed to the front, right and left sides of the subject at an angle of 40 ° In the presence of the stimulus sound in the ipsilateral ear, the transient evoked otoacoustic emissions of the ipsilateral ear was measured at the straight, right and left fixation. In order to evaluate the transient evoked otoacoustic emissions through the efferent auditory pathway, the transient evoked otoacoustic emission values of the contralateral ear were measured at the straight, right and left fixation. These measurements were taken at frequencies of 1 kHz, 1.4 kHz, 2.0 kHz, 2.8 kHz and 4 kHz, respectively. Results : Transient evoked otoacoustic emissions caused by lateral movement of the eye showed significant changes at 1.4 KHz and 2 KHz of the afferent pathway of the ipsilateral ear. Also, significant changes were observed at 1.4 KHz and 4 KHz of the efferent pathway of the contralateral ear. Conclusion : These results indicated that there is a close relationship between eye movement and auditory cochlea. In the future, further studies considering more diverse subjects and age groups will be needed.

Studies on the Sorption and Fixation of Cesium by Vermiculite (II)

  • Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.97-111
    • /
    • 1974
  • The adsorption mechanism of Cs-137 in low level radioactive solution by vermiculite treated with Na ion is studied in order to investigate its effective utilization for the radioactive effluent treatment. The beneficial role of Na-vermiculite is that Na ion can induce the wider c-axis spacing in which Cs ion can be sorbed in vermiculite. Cation exchange capacity and distribution coefficient of cesium seems to be influenced by the variation of c-axis spacing of vermiculite. Comparative identification and detection with the characteristic analyses of X-ray diffraction and electron diffraction patterns, diffrential thermal analysis and electron microscopy of Na-, K- and Cs-vermiculite are studied for the phemomena of Cs adsorption by vermiculite. This importance of the utilization in terms of adsorption and fixation of cesium involving vermiculite is discussed. It is found that the Na-vermiculite is valuable outside charging material for high level radioactive liquid waste storage tank of underground to protect the pollution of the underground water.

  • PDF

A Review on the Carbon Exchange Estimation in Fruit Orchard (과수 재배지의 탄소 수지 평가 연구 동향)

  • Choi, Eun Jung;Suh, Sang Uk;Jeong, Hyun Cheol;Lee, Jong Sik;Kim, Gun Yeob;So, Kyu Ho
    • Journal of Climate Change Research
    • /
    • v.5 no.4
    • /
    • pp.339-348
    • /
    • 2014
  • Agro-ecosystem plays an important role in the mitigation of atmospheric $CO_2$ concentration through photosynthesis and soil carbon fixation. The perennial crops have capacity of carbon accumulation because they have lived for years in the same position. Carbon dioxide fixation occurs in the fruit orchard by photosynthesis and soil carbon sequestration. The objectives of this review are to introduce the fruit orchard as a carbon dioxide sink and to summarize the methods that measure $CO_2$ flux in the orchard. There are three difference methods (chamber, biomass, and eddy covariance method) to measure $CO_2$ exchanges on sites. However, there is no standard method suitable for fruit cultivation condition in Korea. Thus the standard method have to be developed in order to exactly estimate the carbon accumulation. In foreign studies, the carbon assessments were conducted in apple, peach, olive, grape orchard and so on. On the other hand the estimation of $CO_2$ exchange was carried out for apple and mandarine orchard in Korea. According to these results, fruit orchard is a $CO_2$ sink even though amount of carbon accumulation is smaller than the forest. To introduce certainly fruit orchard as greenhouse gas sink, long-term monitoring and further study have to be conducted under each planting condition.

OCCLUSAL FORCE AND EMG CHANGE OF MANDIBULAR FRACTURE (악골 골절에서 술 후 교합압 및 근전도 변화)

  • Choi, Yong-Kwan;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.293-299
    • /
    • 2008
  • Bite force is created by the force of adjacent teeth accompanied with tension of masticatory muscle. The bite force value is greater in male than in female and ha maximum value at first molar. Masseter muscle is associated with bite force and during muscle contraction the electric signal is expressed in EMG form. The aim of the study is to assess recovery time for masseter muscle activity and according to each part of bite force after open reduction with internal fixation when mandibular angle fracture and subcondyle fracture occurred. And to determine the appropriate period for mandibular fracture patients to have normal masticatory activity. 30 patients with normal bite condition was selected for control group and from April, 2007 to September, 2007, 20 patients who visited our department of oral and maxillofacial surgery of Dankook University, were selected for the study and were diagnosed as mandibular angle fracture and subcondyle fracture. For control group, the bite force for incisors, canine, premolars and molars and activity of the masseter muscle was measured and compared for 1, 2, 3, 4, 6 and 8 weeks. That was divided as fracture side and normal side. Mann-Whitney U test was performed for significant difference and the following result was obtained. 1. The maximum voluntary bite force for incisors, canine, premolars and molars portion were 0.113 kN, 0.182kN, 0.295kN and 0.486kN and the masseter muscle activity was 0.192 volts in the control group. 2. The maximum bite force at fracture side was recovered by 4th weeks for incisors, 6th weeks for canine and premolars and 8th weeks for molars and the masseter muscle activity was recovered by 6th weeks in the experimental group. 2. The maximum bite force at normal side was recovered by 4th weeks for incisors, 6th weeks for canine, premolars and molars and the masseter muscle activity was recovered by 3rd weeks in the experimental group. 3. The method for internal fixation by 2.0mm miniplates at both superior and inferior border had no complications according for twenty patients and had a satisfactory recovery. According to the result, patient with mandibular angle fracture and subcondyle fracture, 8 weeks was required for bite force recovery. Therefore, patients with open reduction and internal fixation under general anesthesis, it can be assumed that 8 weeks was needed after operation in order to have normal bite force and masseter muscle recovery.