• 제목/요약/키워드: fitting

Search Result 3,811, Processing Time 0.036 seconds

Determinants of Dual-earner Wives' Needs for Family-supportive Services: A Comparison of Professional and Blue-collar Models (맞벌이 부인의 가족지원서비스 필요도 결정요인 : 전문직과 생산직 모델 비교)

  • Lee, Myung-Shin
    • Korean Journal of Social Welfare
    • /
    • v.36
    • /
    • pp.199-228
    • /
    • 1998
  • This study is designed to find out the determinants of dual-earner wives' needs for family-supportive services. For this purpose, a hypothetical model which explains the relationships among 6 stressors, role overload, stress and needs for 4 family-supportive services is developed. Using the data collected by purposive sampling from 234 professional women and 208 blue-collar women living in Chinju and Sacheon, the hypothetical model developed in this study was tested. In order to examine occupational class differences, a model for professionals and another model for blue-collars were developed separately and compared. For data analysis, a covariance structure analysis was used. The best-fitting model for professional women (df=141, GFI=0.928, CFI=0.965) and the model for blue collar women (df=141, GFI=0.902, CFI=0.912) were found. As a result of comparing two models, 9 common relationships were found:l)Greater dissatisfaction with child care service increases role overload; 2)Longer work hours increases role overload; 3) Higher level of role overload increases stress; 4)Higher level of stress increase needs for leaves; 5)Older child increases needs for flexible work pattern; 6)Younger child increases needs for finalcial assistance for child care fee; 7)needs for financial assistance for child care increases needs for on-site child care services; 8)needs for on-site child care services increases needs for leaves; 9)needs for leaves increases needs for flexible work pattern. With the exception of these 9 common relationships, the analyses revealed substantial differences between professional and blue-collar dual-earner wives. Based on the common and differential needs between 2 groups of wives, the effective ways to provide family-supportive services according to the needs of individual dual-earner wives who are in different familial, financial, and work conditions were suggested.

  • PDF

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function (게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • Objectives: A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and election fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. Materials and Methods: Gated myocardial SPECT was peformed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and election fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. Results: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. Conclusion: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.

Association of Bone Mineral Density with the Metabolic Syndrome (건강검진 수진자들에서 골밀도와 대사증후군의 연관성)

  • Kang, Yeong-Han;Kam, Shin
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.259-266
    • /
    • 2008
  • Objective : The purpose of this study was to examine the relationship between bone mineral density (BMD) and the metabolic syndrome. Method : We conducted a cross-sectional study of 1204 adults(males: 364 females: 840) in a general hospital health promotion center. They were grouped into the normal and lower BMD group according to bone loss(osteopenia, osteoporosis), as determined by duel energy X-ray absorptiometery(DEXA). We analyzed the association between BMD and metabolic syndrome by multiple logistic regression analysis. After adjustment for age, weight, alcohol intake, smoking, regular exercise, regular intake of meals, and menopausal status, odds ratios for the prevalence of the metabolic syndrome by gender were calculated for lower BMD. Results : After adjustment for the effect of potential covariates, the prevalence of metabolic syndrome was associated with bone loss in men(p<0.001). If the odds ratio of normal group is 1.00, then that of the lower BMD group is 3.07(95% CI=1.83-5.16). The prevalence of metabolic alterations fitting the criteria of metabolic syndrome was significantly decreased in High BMI, Low HDL in men and in High BMI in women(p<0.05). Conclusions : This study shows that BMD was associated with metabolic syndrome. Further studies needed to obtain evidence concerning the association between BMD and metabolic syndrome.

  • PDF

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

Analysis of Heterogeneous Tree-Ring Growths of Pinus densiflora with Various Topographical Characteristics in Mt. Worak Using GIS (GIS 기법을 이용한 지형적 특성에 따른 월악산 소나무 연륜생장의 이질성 규명)

  • 서정욱;김재수;박원규
    • The Korean Journal of Ecology
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • To analyze the relationship between climatic factors (monthly temperatures and precipitations) and the radial growths or Pinus densiflora with different topographical settings in Worak National Park, Korea, 20 stands were chosen and 10 trees were selected from each stand. After crossdating, each ring-width series was double detrended (standardized) by fitting first a negative exponential or straight regression line and secondly a 60-year cubic spline. The growth patterns coud be categorized by four groups using cluster analysis. Cluster Ⅰ stand has north aspect, but others have south or southwest aspects. Cluster Ⅰ (one), cluster Ⅱ (ten), and cluster Ⅲ (two) stands are located in lower. elevation (305∼580 m), however, cluster Ⅳ (seven) stands are located in higher elevation, mostly in 560~870 m. Cluster Ⅱ and Ⅲ stands are located at similar elevation with the same aspect, however, cluster Ⅱ stands are located on more rocky and stiff slope with shallow soil depth. The response functions were used to examine the difference in the relationships between climatic factors and tree growths among the 4 cluster chronologies. The climatic factors are not limiting the growth in the cluster Ⅰ stand as highly as in other cluster plots because of rather mesic conditions in the north slope. The precipitation in the spring appears to be the main limiting factor in the cluster Ⅱ stands. The topographical characteristics of the sites of cluster Ⅱ, shallow soil depths on the rocky slope in the south aspect at lower elevation, may enhance the sensitivity of growth to moisture stress. In cluster Ⅲ and cluster Ⅳ, winter and spring temperature prior to the growth become more important than for cluster Ⅱ. This pattern is com-mon for Pinus densiflora trees growing in higher. elevation (equation omitted 800 m) in South Korea. It nay be re-lated with preconditioning effects of temperature as the temperature decreases with increasing elevation (cluster Ⅳ) or in the valley (cluster Ⅲ). The results obtained by tree-ring analysis were digitalized by GIS and spatio-temporal information on tree-ring data and topographic setting were analyzed and displayed simultaneously. The results of this study can be used to predict the future change of Pinus densiflora ecosystem to climate change expected in central Korea.

  • PDF

Corporate Bond Rating Using Various Multiclass Support Vector Machines (다양한 다분류 SVM을 적용한 기업채권평가)

  • Ahn, Hyun-Chul;Kim, Kyoung-Jae
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.157-178
    • /
    • 2009
  • Corporate credit rating is a very important factor in the market for corporate debt. Information concerning corporate operations is often disseminated to market participants through the changes in credit ratings that are published by professional rating agencies, such as Standard and Poor's (S&P) and Moody's Investor Service. Since these agencies generally require a large fee for the service, and the periodically provided ratings sometimes do not reflect the default risk of the company at the time, it may be advantageous for bond-market participants to be able to classify credit ratings before the agencies actually publish them. As a result, it is very important for companies (especially, financial companies) to develop a proper model of credit rating. From a technical perspective, the credit rating constitutes a typical, multiclass, classification problem because rating agencies generally have ten or more categories of ratings. For example, S&P's ratings range from AAA for the highest-quality bonds to D for the lowest-quality bonds. The professional rating agencies emphasize the importance of analysts' subjective judgments in the determination of credit ratings. However, in practice, a mathematical model that uses the financial variables of companies plays an important role in determining credit ratings, since it is convenient to apply and cost efficient. These financial variables include the ratios that represent a company's leverage status, liquidity status, and profitability status. Several statistical and artificial intelligence (AI) techniques have been applied as tools for predicting credit ratings. Among them, artificial neural networks are most prevalent in the area of finance because of their broad applicability to many business problems and their preeminent ability to adapt. However, artificial neural networks also have many defects, including the difficulty in determining the values of the control parameters and the number of processing elements in the layer as well as the risk of over-fitting. Of late, because of their robustness and high accuracy, support vector machines (SVMs) have become popular as a solution for problems with generating accurate prediction. An SVM's solution may be globally optimal because SVMs seek to minimize structural risk. On the other hand, artificial neural network models may tend to find locally optimal solutions because they seek to minimize empirical risk. In addition, no parameters need to be tuned in SVMs, barring the upper bound for non-separable cases in linear SVMs. Since SVMs were originally devised for binary classification, however they are not intrinsically geared for multiclass classifications as in credit ratings. Thus, researchers have tried to extend the original SVM to multiclass classification. Hitherto, a variety of techniques to extend standard SVMs to multiclass SVMs (MSVMs) has been proposed in the literature Only a few types of MSVM are, however, tested using prior studies that apply MSVMs to credit ratings studies. In this study, we examined six different techniques of MSVMs: (1) One-Against-One, (2) One-Against-AIL (3) DAGSVM, (4) ECOC, (5) Method of Weston and Watkins, and (6) Method of Crammer and Singer. In addition, we examined the prediction accuracy of some modified version of conventional MSVM techniques. To find the most appropriate technique of MSVMs for corporate bond rating, we applied all the techniques of MSVMs to a real-world case of credit rating in Korea. The best application is in corporate bond rating, which is the most frequently studied area of credit rating for specific debt issues or other financial obligations. For our study the research data were collected from National Information and Credit Evaluation, Inc., a major bond-rating company in Korea. The data set is comprised of the bond-ratings for the year 2002 and various financial variables for 1,295 companies from the manufacturing industry in Korea. We compared the results of these techniques with one another, and with those of traditional methods for credit ratings, such as multiple discriminant analysis (MDA), multinomial logistic regression (MLOGIT), and artificial neural networks (ANNs). As a result, we found that DAGSVM with an ordered list was the best approach for the prediction of bond rating. In addition, we found that the modified version of ECOC approach can yield higher prediction accuracy for the cases showing clear patterns.

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

Analysis of Cancer Incidence in Zhejiang Cancer Registry in China during 2000 to 2009

  • Du, Ling-Bin;Li, Hui-Zhang;Wang, Xiang-Hui;Zhu, Chen;Liu, Qing-Min;Li, Qi-Long;Li, Xue-Qin;Shen, Yong-Zhou;Zhang, Xin-Pei;Ying, Jiang-Wei;Yu, Chuan-Ding;Mao, Wei-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5839-5843
    • /
    • 2014
  • Objective: The Zhejiang Provincial Cancer Prevention and Control Office collected cancer registration data during 2000 to 2009 from 6 cancer registries in Zhejiang province of China in order to analyze the cancer incidence. Methods: Descriptive analysis included cancer incidence stratified by sex, age and cancer site group. The proportions and cumulative rates of 10 common cancers in different groups were also calculated. Chinese population census in 1982 and Segi's population were used for calculating age-standardized incidence rates. The log-linear model was used for fitting to calculate the incidence trends. Results: The 6 cancer registries in Zhejiang province in China covered a total of 60,087,888 person-years during 2000 to 2009 (males 30,445,904, females 29,641,984). The total number of new cancer cases were 163,104 (males 92,982, females 70,122). The morphology verified cases accounted for 69.7%, and the new cases verified only by information from death certification accounted for 1.23%. The crude incidence rate in Zhejiang cancer registration areas was $271.5/10^5$ during 2000 to 2009 (male $305.41/10^5$, female $236.58/10^5$), age-standardized incidence rates by Chinese standard population (ASIRC) and by world standard population (ASIRW) were $147.1/10^5$ and $188.2/10^5$, the cumulative incidence rate (aged from 0 to 74) being 21.7%. The crude incidence rate was $209.6/10^5$ in 2000, and it increased to $320.20/10^5$ in 2009 (52.8%), with an annual percent change (APC) of 4.51% (95% confidence interval, 3.25%-5.79%). Age-specific incidence rate of 80-84 age group was achieved at the highest point of the incidence curve. Overall with different age groups, the cancer incidences differed, the incidence of liver cancer being highest in 15-44 age group in males; the incidence of breast cancer was the highest in 15-64 age group in females; the incidences of lung cancer were the highest in both males and females over the age of 65 years. Conclusions: Lung cancer, digestive system malignancies and breast cancer are the most common cancers in Zhejiang province in China requiring an especial focus. The incidences of thyroid cancer, prostate cancer, cervical cancer and lymphoma have increased rapidly. Prevention and control measures should be implemented for these cancers.

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.