• Title/Summary/Keyword: first crack

Search Result 630, Processing Time 0.023 seconds

A Study on Source Mechanisms of Micro-Cracks Induced by Rock Fracture (암석파괴시 발생되는 미세균열의 발생원에 대한 연구)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.59-64
    • /
    • 1996
  • Acoustic Emission(AE) signals are emitted by a sudden release of strain energy associated with material damage. A multi-channels of LeCroy system and piezoelectric pressure transducers are employed for AE measurement to investigate the roles of AE in the propagation of macro cracks as well as the characteris-tics of AE wave in occurrence, amplitude and dominant frequency with changes in macro loading modes. Deduced crack opening volume of micro cracks varied widely and implies that AE events could be caused by crystal dislocations on a small scale and grain boundary movements on a large scale. Amplitude of first arrival AE wave emitted during mode I test was approximately 3 times higher than those from mixed mode test, while the number of AE count in mode I test was only 25% of mixed mode. It may imply that the total energy required for generation of a given fracture surface is similar regardless in change of macroloading modes.

  • PDF

An Experiment on Redundancy in Simple Span Two-Girder Bridge - Effects of Lateral Bracing (단경간 2-거더교의 여유도 평가 실험-수평브레이싱의 효과)

  • Park, Yong Myung;Joe, Woon Do Ji;Hwang, Min Oh;Lee, Dae Yong;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.271-280
    • /
    • 2007
  • This paper presents the results of an experimental study to evaluate the redundancy in two plate-girder bridges, which are generally classified as non-redundant load path structures. The study was performed at a time when one of the two girders was damaged. The bottom lateral bracing was considered the experimental variable, and two 1/5-scale bridge specimens of simple span with and without a lateral bracing system were fabricated. Loading tests were first performed on the intact specimens without a cracked girder, within an elastic range. Thereafter, the ultimate loading tests were conducted on the damaged specimens with an induced crack at the center of a girder. The test results showed that the cross beams and the concrete deck redistributed some of the load to the uncracked girder, but the lateral bracing system played an important role in improving the redundancy during the damage and was also effective for load redistribution even when the bridge was intact.

Saw-tooth softening/stiffening - a stable computational procedure for RC structures

  • Rots, Jan G.;Invernizzi, Stefano;Belletti, Beatrice
    • Computers and Concrete
    • /
    • v.3 no.4
    • /
    • pp.213-233
    • /
    • 2006
  • Over the past years techniques for non-linear analysis have been enhanced significantly via improved solution procedures, extended finite element techniques and increased robustness of constitutive models. Nevertheless, problems remain, especially for real world structures of softening materials like concrete. The softening gives negative stiffness and risk of bifurcations due to multiple cracks that compete to survive. Incremental-iterative techniques have difficulties in selecting and handling the local peaks and snap-backs. In this contribution, an alternative method is proposed. The softening diagram of negative slope is replaced by a saw-tooth diagram of positive slopes. The incremental-iterative Newton method is replaced by a series of linear analyses using a special scaling technique with subsequent stiffness/strength reduction per critical element. It is shown that this event-by-event strategy is robust and reliable. First, the model is shown to be objective with respect to mesh refinement. Next, the example of a large-scale dog-bone specimen in direct tension is analyzed using an isotropic version of the saw-tooth model. The model is capable of automatically providing the snap-back response. Subsequently, the saw-tooth model is extended to include anisotropy for fixed crack directions to accommodate both tensile cracking and compression strut action for reinforced concrete. Three different reinforced concrete structures are analyzed, a tension-pull specimen, a slender beam and a slab. In all cases, the model naturally provides the local peaks and snap-backs associated with the subsequent development of primary cracks starting from the rebar. The secant saw-tooth stiffness is always positive and the analysis always 'converges'. Bifurcations are prevented due to the scaling technique.

Structural Safety Assessment of Independent Spherical LNG Tank(1st Report) - Fatigue Strength Analysis Based on the S-N Approach - (독립구형 LNG 탱크의 구조안전성 평가(제1보) - 피로균열 발생수명 예측 -)

  • In-Sik Nho;Yong-Yun Nam;Ho-Sup Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.132-140
    • /
    • 1993
  • The design of LNG ship needs very high level structural design/analysis technology compared with conventional ship types because it requires perfect security against the extremly dangerous and cryogenic cargo. Hence, present paper describes the general procedure of the structural safety assessment for independent tank type LNG ship, which contains following items. 1) Long term prediction of the wave induced stresses including ship motion analysis, structural analysis of hull and tank and stochastic analysis process of ocean waves. 2) Fatigue strength analysis of a tank structure based on the S-N approach. 3) Structural safety assessment against the fatigue crack propagation based on the LBF(Leak Before Failure) concept. The first report focuced on the item (1) (2) and example calculation was performed on a prototype LNG ship. The remained part will be covered by the second report.

  • PDF

Deleuze and Guattari's Death, the Minor Literature and the Minor Philosophy of Education (소수자 문학과 문학교육의 과제)

  • Yoon, Seung Ri
    • Korean Educational Research Journal
    • /
    • v.40 no.3
    • /
    • pp.39-65
    • /
    • 2019
  • This essay examines the relationship between death and the minor literature and the minor philosophy of education. Deleuze and Guattari conceive death as the source of question and the problem. Death overcomes Freud's death-drive and is conceived as the universal event. Then, death is understood as the essential problem, the condition of thought about life, and the paradox of actuality. On the other hand, their minor literature is able to figure in Kafka's works, Metamorphosis and so on, excellently. Deleuze and Guattari argue that Kafka's works push ahead to the edge of the deterritorization. Their argument on the minor literature has the following three characteristics: first, the territorization of the language; second, the directional connection between the individual and the social; third, the collective arrangement of the statement. Death and the minor literature share the "intensity" as the theoretical tool and thus presuppose each other. From this, we are able to draw the possibility of the minor philosophy of education. It makes a crack on the major philosophy of education, exposing the limitation of the doctrines. In other words, the major philosophy of education enforces the reading of grand philosophers by the defined ways only. Instead, Deleuze and Guattari show the creative way through their research of the history of philosophy and extend the field of thought. In following this way, we can repeat the novel in the philosophy of education also. In this essay, we examine their "affect" for the possibility.

  • PDF

Repair of Pre-cracked Reinforced Concrete (RC) Beams with Openings Strengthened Using FRP Sheets Under Sustained Load

  • Osman, Bashir H.;Wu, Erjun;Ji, Bohai;Abdulhameed, Suhaib S.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.171-183
    • /
    • 2017
  • Strengthening reinforced concrete (RC) beams with openings by using aramid fiber reinforcement polymers (AFRP) on the beams' surfaces offers a useful solution for upgrading concrete structures to carry heavy loads. This paper presents a repairing technique of the AFRP sheets that effectively strengthens RC beams, controls both the failure modes and the stress distribution around the beam chords and enhances the serviceability (deflection produced under working loads be sufficiently small and cracking be controlled) of pre-cracked RC beams with openings. To investigate the possible damage that was caused by the service load and to simulate the structure behavior in the site, a comprehensive experimental study was performed. Two unstrengthened control beams, four beams that were pre-cracked before the application of the AFRP sheets and one beam that was strengthened without pre-cracking were tested. Cracking was first induced, followed by repair using various orientations of AFRP sheets, and then the beams were tested to failure. This load was kept constant during the strengthening process. The results show that both the preexisting damage level and the FRP orientation have a significant effect on strengthening effectiveness and failure mode. All of the strengthened specimens exhibited higher capacities with capacity enhancements ranging from 21.8 to 66.4%, and the crack width reduced by 25.6-82.7% at failure load compared to the control beam. Finally, the authors present a comparison between the experimental results and the predictions using the ACI 440.2R-08 guidelines.

A Study on the Performance Assessment of PHWR Containment Building (가압중수형 원전 격납건물의 성능평가에 관한 연구)

  • Lee, Hong-Pyo;Jang, Jung-Bum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.449-455
    • /
    • 2011
  • Recently, international collaborative research which was organized at Bhabha Atomic Research Centre in India, was conducted to develop for pressure capacity and nonlinear behavior of PHWR 1/4 scale nuclear containment building between experimental test and numerical code. In this paper, a nonlinear finite element analysis was carried out in order to predict ultimate pressure capacity and nonlinear behavior of the 1/4 scale containment building. The 1/4 scale containment building is consisted of basemat, cylinder wall, dome and 4-buttress. For the finite element analysis, commercial program ABAQUS was used. Finite element models including concrete, rebar and tendon have been developed for assessment of ultimate pressure capacity and failure mode for nuclear containment building. From the analysis results, first crack of the concrete, the yielding of the rebar and ultimate capacity pressure occurred at $1.6P_d$(design pressure), $3.36P_d$ and $4.0P_d$, respectively.

The 3D-numerical simulation on failure process of concrete-filled tubular (CFT) stub columns under uniaxial compression

  • Zhu, W.C.;Ling, L.;Tang, C.A.;Kang, Y.M.;Xie, L.M.
    • Computers and Concrete
    • /
    • v.9 no.4
    • /
    • pp.257-273
    • /
    • 2012
  • Based on the heterogeneous characterization of concrete at mesoscopic level, Realistic Failure Process Analysis ($RFPA^{3D}$) code is used to simulate the failure process of concrete-filled tubular (CFT) stub columns. The results obtained from the numerical simulations are firstly verified against the existing experimental results. An extensive parametric study is conducted to investigate the effects of different concrete strength on the behaviour and load-bearing capacity of the CFT stub columns. The strength of concrete considered in this study ranges from 30 to 110 MPa. Both the load-bearing capacity and load-displacement curves of CFT columns are evaluated. In particular, the crack propagation during the deformation and failure processes of the columns is predicted and the associated mechanisms related to the increased load-bearing capacity of the columns are clarified. The numerical results indicate that there are two mechanisms controlling the failure of the CFT columns. For the CFT columns with the lower concrete strength, they damage when the steel tube yields at first. By contrast, for the columns with high concrete strength it is the damage of concrete that controls the overall loading capacity of the CFT columns. The simulation results also demonstrate that $RFPA^{3D}$ is not only a useful and effective tool to simulate the concrete-filled steel tubular columns, but also a valuable reference for the practice of engineering design.

Rehabilitation of normal and self-compacted steel fiber reinforced concrete corbels via basalt fiber

  • Gulsan, Mehmet Eren;Al Jawahery, Mohammed S.;Alshawaf, Adnan H.;Hussein, Twana A.;Abdulhaleem, Khamees N.;Cevik, Abdulkadir
    • Advances in concrete construction
    • /
    • v.6 no.5
    • /
    • pp.423-463
    • /
    • 2018
  • This paper investigates the behavior of normal and self-compacted steel fiber reinforced concrete (SCC-SFRC) corbels rehabilitated by Basalt Fiber Mesh (BFM) and Basalt Fiber Fabric (BFF) for the first time in literature. The research objective is to study the effectiveness of BFM and BFF in the rehabilitation of damaged reinforced concrete corbels with and without epoxy injection. The experimental program includes two types of concrete: normal concrete, and self-compacted concrete. For normal concrete, 12 corbels were rehabilitated by BFM without injection epoxy in cracks, with two values of compressive strength, three ratios of steel fiber (SF), and two values of shear span. For self-compacted concrete, 48 corbels were rehabilitated with different parameters where 12 corbels were rehabilitated by BFM with and without epoxy injection, 18 heated corbels with three different high-temperature level were rehabilitated by repairing cracks only by epoxy injection, and 18 heated corbels with three different high-temperature level were rehabilitated by repairing cracks by epoxy and wrapping by BFF. All 48 corbels have two values of compressive strength, three values volumetric ratios of SF, and two values of the shear span. Test results indicate that RC corbels rehabilitated by BFM only without injection did not show any increase in the ultimate load capacity. Moreover, For RC corbels that were repaired by epoxy without basalt wrapping, the ultimate load capacities showed an increase depending on the mode of failure of corbels before the rehabilitation. However, the rehabilitation with only crack repairing by epoxy injection is more effective on medium strength corbels as compared to high strength ones. Finally, it can be concluded that use of BFF is an effective and powerful technique for the strengthening of damaged RC corbels.

Piping Failure Frequency Analysis for the Main Feedwater System in Domestic Nuclear Power Plants

  • Choi Sun Yeong;Choi Young Hwan
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.112-120
    • /
    • 2004
  • The purpose of this paper is to analyze the piping failure frequency for the main feedwater system in domestic nuclear power plants(NPPs) for the application to an in-service inspection(ISI), leak before break(LBB) concept, aging management program(AMP), and probabilistic safety analysis(PSA). First, a database was developed for piping failure events in domestic NPPs, and 23 domestic piping failure events were collected. Among the 23 events, 12 locations of wall thinning due to flow accelerated corrosion(FAC) were identified in the main feedwater system in 4 domestic WH 3-loop NPPs. Two types of the piping failure frequency such as the damage frequency and rupture frequency were considered in this study. The damage frequency was calculated from both the plant population data and damage(s) including crack, wall thinning, leak, and/or rupture, while the rupture frequency was estimated by using both the well-known Jeffreys method and a new method considering the degradation due to FAC. The results showed that the damage frequencies based on the number of the base metal piping susceptible to FAC ranged from $1.26{\times}10^{-3}/cr.yr\;to\;3.91{\times}10^{-3}/cr.yr$ for the main feedwater system of domestic WH 3-loop NPPs. The rupture frequencies obtained from the Jeffreys method for the main feedwater system were $1.01{\times}10^{-2}/cr.yr\;and\;4.54{\times}10^{-3}/cr.yr$ for the domestic WH 3-loop NPPs and all the other domestic PWR NPPs respectively, while those from the new method considering the degradation were higher than those from the Jeffreys method by about an order of one.