• 제목/요약/키워드: fire scenario

검색결과 241건 처리시간 0.027초

시뮬레이션을 이용한 철도터널 화재 사고의 승객 안전도 분석 (A Study on Analysis of Passenger Safety in Railroad Tunnel Fire - Using Simulation -)

  • 김동진;문성암;김동건;김경섭;장용준;정우성
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.131-136
    • /
    • 2007
  • In this paper, the methodology to predict the number of deaths and possible fire propagation scenarios will be described in case of fire on a train in a tunnel. We use a probabilistic analysis method for the evaluation of possibility for each scenario and the deaths tolls are calculated with the help of the passenger evacuation simulation program. The resulting safety of passengers is displayed on a F/N graph, which could be used in part as a guideline to predict the safety level of the tunnel in fire.

변전소 주변압기실 미분무수 소화시스템 성능평가를 위한 화재시나리오 (A Fire Scenario for Application of Water Mist System to an Indoor Power Transformer Room)

  • 최병일;한용식;김명배
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.52-57
    • /
    • 2005
  • 미분무수 소화시스템의 소화구조는 분무되는 물의 조건뿐만 아니라 방호대상 공간의 상태에도 의존하기 때문에 일반적인 설계기준을 마련 할 수 없는 실정이다. 따라서 보편적인 성능평가 방법도 있을 수 없기 때문에 방호 대상물과 공간이 결정되면 그에 적절한 성능평가 기준이 마련되어야 한다. 본 연구에서는 변전소 주변압기실에 미분무수 소화시스템을 적용하기 위하여 성능평가 기준을 제안하고자 한다. 이를 위하여 유사 화재사례 조사, 사고 분석, 유사 성능평가기준 분석 등을 수행하였다.

Evaluating fire resistance of prestressed concrete bridge girders

  • Zhang, Gang;Kodur, Venkatesh;Hou, Wei;He, Shuanhai
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.663-674
    • /
    • 2017
  • This paper presents an approach for evaluating performance of prestressed concrete (PC) bridge girders exposed to fire. A finite element based numerical model for tracing the response of fire exposed T girders is developed in ANSYS. The analysis is carried out in three stages, namely, fire temperature calculation, cross sectional temperature evaluation, and then strength, deformation and effective prestress analysis on girders exposed to elevated temperatures. The applicability of the computer program in tracing the response of PC bridge girders from the initial preloading stage to failure stage, due to combined effects of fire and structure loading, is demonstrated through a case study, and validated by test data of a scaled PC box girder under ISO834 fire condition. Results from the case study show that fire severity has a significant influence on the fire resistance of PC T girders and hydrocarbon fire is most dangerous for the girder. The prestress loss caused by elevated temperature is about 10% under hydrocarbon fire till the girder failure, which can lead to the increase in deflection of the PC girder. The rate of deflection failure criterion is suggested to determine the failure of PC T girder under fire.

USN 기반 개방형 방재관리 통합시스템 개발 (Development of an USN Based Integrated Open Server System for Disaster Prevention Management)

  • 이정균;이기영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.929-932
    • /
    • 2007
  • 본 논문에서는 USN 내부의 센서를 통해 신속 정확한 화재 정보를 수신하여 방재관련 기타 시스템과 연계를 통해 각종 방재 자료를 정보화하고, 효과적인 소방시설의 유지관리에 중점을 두기 위하여 기존에 운용되고 있는 각종 설비의 관리시스템의 유기적인 통합 지원체계를 구축한 개방형 프로토콜을 지원하는 통합 방재 관리시스템을 구현하였다. 이를 검증하기 위해 CCTV설비, 고감도 환경 감지기, 자동화재탐지설비, 출입문 보안설비, 공조설비와 같은 Local 시스템을 개방형 네트워크를 이용하여 통합하고, 운영을 하기위한 운영 시나리오 검증과 통합방재 관리시스템의 서버 구조의 유효성을 검증하였다.

  • PDF

미분무 소화시스템을 이용한 철도차량 실물화재 진압실험 (Fire Suppression Tests for a Train Using Water Mist Systems)

  • 최병일;한용식;도규형;김명배;이동찬
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.57-65
    • /
    • 2009
  • 미분무 소화시스템을 이용하여 철도차량 내부 화재진압 실험을 수행하였다. 실험차량은 실물 철도차량이며, 화재시나리오는 표면화재 1종, 유류화재 1종, 그리고 미분무 소화시스템에 의한 화재 공간 내의 공간 냉각 능력을 조사하기 위한 차폐화재 1종 등 총 3종이었다. 실험에 사용된 소화시스템은 6종으로, 일정압력을 가지는 소화시스템 5종, 질소가압 압력용기로부터 분사되는 소화시스템 1종이다. 실험 결과 미분무 소화시스템이 철도 차량 내부의 화재를 효과적으로 소화시키거나, 소화가 되지 않더라도 우수한 공간 냉각 능력으로 화재 피해를 최소화할 수 있음을 알았다.

오감인지를 통한 지하철 화재 비상대응시스템에 관한 연구 (A Study on the Emergency Response System by Five Sense in the Subway Fire)

  • 노삼규;함은구
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.76-83
    • /
    • 2008
  • 지하철 화재사고 경우 정확한 화재 유형 파악과 그에 따른 적절한 초기대응은 사고피해를 최소화하기 위한 중요한 사항이다. 그러나 지하철 화재사고 발생 시 기관사 또는 비상대응직원이 직접 목격하지 않으면 화재 유형을 즉시 파악하기란 불가능하다. 본 연구에서는 화재사고로 나타날 수 있는 오감(五感) 유형을 분석하여 오감 정보를 통해 신속한 화재사고 정보를 전달할 수 있도록 오감 유형을 제안하였다. 또한, 화재 시나리오에 따른 비상대응을 Activity-Action Diagram(AAD)로 정의하여 비상대응을 시스템화 하기 위한 기반을 제시하였다.

Modifications to fire resistance ratings of steel frames based on structural configuration: A probabilistic-based approach

  • Behnam, Behrouz
    • Structural Engineering and Mechanics
    • /
    • 제77권5호
    • /
    • pp.661-672
    • /
    • 2021
  • In this article, the role of spans number and length in fire-resistance ratings (FRRs) of fireproofed steel frames are investigated. First, over a span-lengthening scenario, two one- and three-bay frames under the ISO834 fire are examined. It is shown that the FRRs of the frames rely highly on the changes made on their span length. Second, a building designed for three spans number of three, four, and five under natural fire is investigated. The beams are designed for two load-capacity-ratios (LCRs) of optimum and ultimate. The fire curves are determined through a probabilistic-based approach. It is shown that the structural vulnerability vastly increases while the number of spans decreases. The results show that for an optimum LCR, while the five-span frame can meet the required FRR in 87% of the fire scenarios, the four- and three-span frames can meet the required FRR in only 56%, and 50% of the fire scenarios, respectively. For an ultimate LCR, the five-, four- and three-span frames can meet the required FRR in 81%, 50%, and 37.5% of the fire scenarios, respectively. Functional solutions are then proposed to resolve the insufficiencies in the results and to rectify the application of the standard-based FRRs in the cases studied. The study here highlights how employing current standard-based FRRs can endanger structural safety if they are not connected to structural characteristics; a crucial hint specifically for the structural engineering community who may be not well familiar with the fundamentals of performance-based approaches.

B도시지역 고층 주상복합건축물 성능위주설계도서 분석을 통한 화재 시뮬레이션 분야 개선방안에 관한 연구 (A Study on Improvement Way of Fire Simulation Modelling Field through Analysis of Performance-Based Design Reports of High-rise Residential Complex Building in B Metropolitan City)

  • 서민지;이양주;안성호;황철홍;최준호
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.80-85
    • /
    • 2017
  • 최근 우리나라에서는 초고층 건축물의 신축이 급증하고 있어 화재 발생 시 인명 및 재산피해를 최소화하기 위해 현행 법규와 동등 이상의 성능을 요구하는 '성능위주설계'를 의무적으로 시행하고 있다. 그러나 성능위주설계에서 큰 비중을 차지하고 있는 화재 및 피난 시뮬레이션 분야는 아직 세부적인 기술적 가이드라인이 제정되지 않아 설계자들이 앞서 수행했던 여러 설계도서들을 참고하여 그와 유사하게 진행하고 있는 실정이다. 그 중에서도 화재시뮬레이션의 경우에는 설계자의 판단에 따라 시나리오 유형을 선정하고 임의로 입력값을 설정하고 있어 같은 용도의 건축물이라 하더라도 누가 어떻게 설계했느냐에 따라 다른 결과가 도출되고 있는 것도 사실이다. 이에 본 논문에서는 실제 B도시지역에 접수된 성능위주설계(건축심의 전 단계) 도서 7건을 무작위로 조사하여 화재시나리오 유형과 시나리오별 입력조건 현황을 파악하고 합리적인 화재시뮬레이션의 수행을 위한 개선방안을 제시하여 기술적 가이드라인 제정에 대한 초석을 다지고자 한다.

실내공간정보를 활용한 비콘기반 화재위험감지와 재실자 피난지원 서비스에 관한 연구 (A Study on Fire Evacuation Guidance System using Indoor Spatial Information from Beacon)

  • 이선민;김태경;홍성문;김주형;김재준
    • 한국BIM학회 논문집
    • /
    • 제6권3호
    • /
    • pp.15-23
    • /
    • 2016
  • The purpose of this study is to present the possibility of adopting beacons to implement the fire evacuation guidance system in order to reduce the evacuation time for a fire in complex buildings. A beacon-based evacuation system can quickly detect a fire's origin, optimal path of evacuation involved with the exits and the location of evacuees using information collected by the proposed system. The assessment is conducted by integrating different scenario models including fire simulation. Based on the research result, beacon is an effective tool to warn potential hazards or to provide early detection and a safe escape.

Effect of Vertically Travelling Fires on the Collapse of Tall Buildings

  • Kotsovinos, Panagiotis;Jiang, Yaqiang;Usmani, Asif
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.49-62
    • /
    • 2013
  • Many previous tall building fires demonstrate that despite code compliant construction fires often spread vertically and burn over multiple floors at the same time. The collapses of the WTC complex buildings in 9/11 as well as other partial collapses like the ones of the Windsor Tower in Madrid and of the Technical University of Delft building posed new questions on the stability of tall buildings in fire. These accidents have shown that local or global collapse is possible in multi-floor fires. In most of the previous work involving multi-floor fires all floors were assumed to be heated simultaneously although in reality fires travel from one floor to another. This paper extends previous research by focusing on the collapse mechanisms of tall buildings in fire and performs a parametric study using various travelling rates. The results of the study demonstrate that vertically travelling fires have beneficial impact in terms of the global structural response of tall buildings in comparison to simultaneous fires. Contrary to the beneficial effect of the travelling fires in terms of the global structural response, it was noticed that higher tensile forces were also present in the floors compared to simultaneous multi-floor case. Designers are therefore advised to consider simultaneous multi-floor fire as an upper bound scenario. However, a scenario where a travelling fire is used is also suggested to be examined, as the tensile capacity of connections may be underestimated.