• Title/Summary/Keyword: fire risk assessment system

Search Result 100, Processing Time 0.028 seconds

A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate (방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구)

  • Oh, Chan-Wook;Oh, Ryun-Seok;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.56-62
    • /
    • 2019
  • A sprinkler is a fire extinguishing equipment installed in a protected area where a detector or head detects a fire and automatically puts out the fire. However, the Ministry of Land, Infrastructure and Transport's "Regulations on Building Evacuation and Fire Protection Standards, etc." stipulate that fire compartment area should be reduced to three times by installing sprinkler facilities in the case of factories and warehouses. In this study, fire hazard was analyzed for a real PCB factory which mitigated the fire protection zone by sprinkler installation, and the head opening characteristics of sprinkler facilities through computer simulation, installation standards of sprinkler facilities, thermal performance, operating range, and the amount of water sprayed to identify the problems of operation of sprinkler facilities in case of fire, and to suggest the grounds such as required sprinkling flow rate for system improvement.

A Study on the Optimum Disaster Mitigation Activity to Establish the Early Counter System on the Industrial Accidents (산업체재난 조기 대응체계 구축을 위한 최적 재해경감활동 방안 연구)

  • Lee, Keun-Jae;Yoon, Myong-O;Lee, Won-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.9-20
    • /
    • 2010
  • This study indicates direction on establishment of the operational plan for disaster mitigation and its implementation for maintaining business continuity of the local company of the first step, and seeks plans for maintaining their continuity through the establishment of early counter system constructed for achieving lasting safe at the any disaster. For achieving it, we investigated the standard of disaster management selected by the government called "Incident Preparedness and Operational Continuity Plan" Guideline, and investigated a guideline to be easily applied to domestic companies. And, we also studied on how to build the operational plan of disaster mitigation and apply IT techniques to A corporation. Especially, this study indicates the models of establishment of risk assessment, impact analysis, prevention and mitigation plan, response management plan for the establishment of plan among 5 main steps on "Incident Preparedness and Operational Continuity Management" Guideline. We devised the plan to activate the disaster mitigation activity throughout the country. It shows the skills to be prepared to upgrade the level of disaster response in this study.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

A Study on the Consequences of Underground High Pressure Natural Gas Pipelines (고압 매몰 천연가스 배관 누출사고 피해해석에 관한 연구)

  • Lee, Seungkuk;Shin, Hun Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.44-49
    • /
    • 2013
  • Due to rapid rise of consuming rate for natural gas, installation and operation of high pressure natural gas pipeline is inevitable for high rate of gas transportation. Accordingly incidents on the underground high pressure natural gas pipeline come from various reasons will lead to massive release of natural gas and gas dispersion in the air. Further, fire and explosion from ignition of released gas may cause large damage. This study is for release rate, dispersion and flash fire of natural gas to establish a safety management system, setting emergency plan and safety distance.

Assessing the risk of work-related musculoskeletal disorders in 119 EMT: a focus on patient-carrying tasks (119구급대원의 업무 관련성 근골격계 질환 위험성 평가 : 환자 운반 작업을 중심으로)

  • Jeong-Won Son
    • The Korean Journal of Emergency Medical Services
    • /
    • v.27 no.3
    • /
    • pp.33-46
    • /
    • 2023
  • Purpose: This study aims to evaluate the risk of work-related musculoskeletal disorders (WMSDs) in 119 EMT during patient-carrying tasks using a long backboard (LBB) and a variable stretcher. Methods: Manikins were used as patients, and 45 new 119 EMT from K Fire Academy were filmed performing patient-carrying tasks on stairs. The tasks were analyzed using Ovako working posture analysis system (OWAS) and Rapid entire body assessment (REBA). Results: In using LBB, the OWAS score was Mode 3(Mean 2.37, Maximum 3), requiring as soon as possible corrective action, the REBA score was Mode 11(Mean 9.16, Maximum 11), requiring immediate improvement. In using variable stretcher, the OWAS score was Mode 1(Mean 2.33, Maximum 3), non-necessity for corrective action, the REBA score was Mode 9(Mean 8.0, Maximum 11), requiring as soon as possible. Conclusion: In conclusion, improvement was needed in one task (carrying a patient using a LBB) in the OWAS and in two tasks (carrying a patient using a LBB, carrying a patient using a variable stretcher) in the REBA. Thereby, required attention and management of WMSDs during training. In addition, it is essential to carry out objective and quantitative assessments through ergonomic analysis by occupational health professionals when designing future training programs to prevent WMSDs.

A Study for Deducing the Problems and Improvements of Health Safety and Welfare Policy for Korean Firefighters by Delphi (델파이 기법을 통한 소방공무원 보건안전정책의 문제점 및 개선방안 도출)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • Purpose: In this study, we will try to find out problems and improvements of the policies in order to verify whether the plans contribute to the health and welfare of the firefighters properly. Method: By the Delphi analysis by experts. Result: There are problems such as absence of Firefighters' hospital, insufficient mental health education program in fire department, lack of on-site risk assessment system, problem on ineffectiveness of mental and physical health care business, lack of substantiality on mental and physical stability program, absence of mental health education, ensuring the confidentiality for users of mental health programs, lack of support for parent firefighters, lack of firefighters' retirement design and insufficient treatment for female firefighters. Conclusion: There are Improvements such as establishing Firefighters' hospital, improving mental health education and training CISD leaders in the fire department, preparing disaster risk assessment system, effectiveness measurement for visiting psychological counseling projects, improving the program through customer satisfaction surveys, establishment of mental health education system, ensuring confidentiality by improving personnel systems, encourage childcare leave and introduce childcare facilities at fire stations, revitalizing retirement Firefighters and policy development for female firefighters.

A Field Survey of Rack-Type Warehouse for Commodity Classification System in Korea (국내 랙크식 창고 수용물품 등급분류를 위한 현장조사)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.98-105
    • /
    • 2016
  • A fire risk assessment in rack-type warehouse is typically determined based on the following factors: 1. flammability and fire loads for storage of goods, packing materials, and pallet, 2. a ceiling height of warehouse indoor spaces, and 3. height, arrangement, and spacing for storage racks. For appropriately extinguishing and protecting the fire in warehouses, therefore, it is necessary to classify combustibles considering the previously mentioned factors and to develop design Standards for sprinkler system. As the first step to apply automatic sprinkler system to domestic warehouses, this study investigated characteristics for commodity distribution and warehouse configuration using 28 warehouses in five distribution complexes located in Gyeonggi-do, South Korea. In addition, this study analyzed Standards for commodity distribution adopted in USA, Europe, and Japan. Using the field survey analysis, this study was aimed to provide baseline data to prepare for Commodity Classification Standard for warehouses in South Korea.

A Study on the Development of the Response Resource Model of Hazardous and Noxious Substances Based on the Risks of Marine Accidents in Korea (위험도에 기반한 HNS 방제자원 모델 개발에 관한 연구)

  • Lee, Eun-Bang;Yun, Jong-Hwui;Chung, Sang-Tae
    • Journal of Navigation and Port Research
    • /
    • v.36 no.10
    • /
    • pp.857-864
    • /
    • 2012
  • Reviewing the statistics of harbor shipment of hazardous and noxious substance and the past spill accidents of HNS enabled us to assess the potential risks of transportation of HNS through the major harbors in Korea. Ulsan, Yeosu, Daesan port are relatively evaluated high risk in fire, health and environment disaster. Through the analysis of domestic preparedness to HNS accidents, the supplement of expertise resource to respond the vulnerability of the explosion, the fire and the physiological hazard, is required. Based on this risk assessment and review of the advanced case of Japan in building up HNS response system, a resource model at a national level was proposed which differentiates the sea areas for the proper allocation of resources to respond effectively to HNS accidents in the future.

Dynamic quantitative risk assessment of accidents induced by leakage on offshore platforms using DEMATEL-BN

  • Meng, Xiangkun;Chen, Guoming;Zhu, Gaogeng;Zhu, Yuan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.22-32
    • /
    • 2019
  • On offshore platforms, oil and gas leaks are apt to be the initial events of major accidents that may result in significant loss of life and property damage. To prevent accidents induced by leakage, it is vital to perform a case-specific and accurate risk assessment. This paper presents an integrated method of Ddynamic Qquantitative Rrisk Aassessment (DQRA)-using the Decision Making Trial and Evaluation Laboratory (DEMATEL)-Bayesian Network (BN)-for evaluation of the system vulnerabilities and prediction of the occurrence probabilities of accidents induced by leakage. In the method, three-level indicators are established to identify factors, events, and subsystems that may lead to leakage, fire, and explosion. The critical indicators that directly influence the evolution of risk are identified using DEMATEL. Then, a sequential model is developed to describe the escalation of initial events using an Event Tree (ET), which is converted into a BN to calculate the posterior probabilities of indicators. Using the newly introduced accident precursor data, the failure probabilities of safety barriers and basic factors, and the occurrence probabilities of different consequences can be updated using the BN. The proposed method overcomes the limitations of traditional methods that cannot effectively utilize the operational data of platforms. This work shows trends of accident risks over time and provides useful information for risk control of floating marine platforms.

The Development of Quantitative Audit System for Safety Management Systems based on Accident Database (사고 데이터베이스를 활용한 안전 관리 시스템의 정량적 Audit 시스템 개발)

  • Ahn, Sung Joon;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • In the chemical process industries, accidents have a high potential and large effects on catastrophic results. Therefore the safety management for accident prevention plays a crucial role to guarantee the process safety. For these reasons, many systematic methods for safety management system have been widely employed in the fields of chemical processes. PSM (Process safety management) is one of most representative methods. The audit system, which is one of PSM system components, evaluates the performance of PMS system. However, most existing safety audit systems are not systematic and these are performed based on knowledges and experiences of various specialist. Moreover, the safety audit is only performed based on each independent technical component. So, the results of safety audit are not a quantitative index but only a series of commentaries. Finally, it is very difficult to obtain the comparison with other plants or industries. In this study, the novel systematic method and index-based accident database of auditing safety management systems for quantitative assessment are proposed. First, the elements of safety audit replace technical methods to categories of accident database. The F-N curve of each category for accident database is employed to derive the index for quantitative assessment. The Accidental Factor Risk Index (AFRI) is suggested for evaluating the effect of each element in accident database and safety audit system. The safety audit can be modified according to the proposed index.