• Title/Summary/Keyword: fire risk

Search Result 1,159, Processing Time 0.036 seconds

Implementation of ELB Leakage Current Control System based on ZigBee Communication (ZigBee통신 기반 ELB 누전전류 제어시스템 구현)

  • Ju, Jae-Han
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.52-57
    • /
    • 2012
  • Social development as well as the development of consumer electronic devices due to leakage, electric shock or fire, and many are exposed to the risk of leakage currents. Premises in the control cabinet, but the circuit breaker is installed, the existing circuit breaker shuts off when a short circuit in the control cabinet, installed only have the capability. Also connected to the outlet is installed byeokmada family of devices is not easy thing to check individually. In this paper, circuit breakers and circuit analysis and circuit performance, ZigBee-based premises of consumer electronics devices using sensors to monitor the health of the leakage can be presented on how. Performance analysis, the proposed ELB leakage current control system is built into the appliance leakage circuit breaker for each household appliances because the application can check the status of a short circuit, short circuit, over the existing system can be monitored easily.

Arc Fault Circuit Interrupter Design using Microprocessor (마이크로프로세서를 이용한 아크결함 차단기 설계)

  • Yoon, Kwang-Ho;Ban, Gi-Jong;Lee, Hyo-Jik;Park, Byung-Suk;Nam, Moon-Hyon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.12-18
    • /
    • 2007
  • As an arc fault interrupter, the AFCI mentioned in this paper has been designed to detect and interrupt arc faults due to wire deterioration, insulation, wire damage, loose connection, and excessive mechanical damage. Since AFCI is digital and uses mechanical and electric stress, the length of interruption against overload and over-current is much shorter than the current bi-metal method. Therefore, the risk of electrical fires has been reduced.

Risk Factors of Electrical Fire at the Panelboard and Investigation of Field Conditions (분전반에서의 전기화재 위험요소 및 현장실태조사 분석)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Lee, Ki-Yeon;Choi, Yong-Sung;Choi, Chung-Seog;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2206-2207
    • /
    • 2008
  • 본 논문에서는 분전반에서의 화재 위험 요소와 화재위험 요소에 대한 현장 실태조사 결과를 분석하였다. 분전반에서의 화재 위험 요소는 크게 전기적 요인, 환경적 요인, 물리적 요인으로 나눌 수 있으며 전기적 요인으로는 단락, 과부하(과전류), 접촉불량, 전류 불평형 등이 있으며 환경적 요인으로는 수분(염분 등), 먼지(분진, 목분, 철분 등), 온도(고온) 등에 의한 절연파괴, 기기 손상, 오동작 등이 있다. 물리적 요인으로는 기계적인 진동이나 충격 등에 의한 전기적 접속부의 이완에 의한 발열 등을 들 수 있다. 이러한 화재 위험 요인에 대하여 현장실태조사를 실시한 결과, 일부 분전반에서 내부에 먼지 등 이물질이 차단기, 전선, 단자대 등의 표면에 부착되어 있음을 확인할 수 있었으며 수분이나 염분 등의 영향으로 전극간 절연물 표면의 열화로 화재가 발생할 가능성이 있다. 또한, 적외선 열화상 분석결과, 일부 차단기 단자에서 국부 발열이 관측되었으며, 부하 분담의 불평형에 의한 발열도 확인되었다. 이러한 위험요인에 의한 화재 예방을 위하여 규정된 전선 굵기의 사용과 적정 체결압력의 확보, 상간 전류 불평형을 줄이기 위한 부하 분담의 조정이 필요하다. 향후, 분전반에서의 전기화재, 감전사고 등 전기재해의 예방을 위하여 지속적이고 체계적인 유지관리는 물론 사고 발생 전에 이상 징후를 사전에 감지하여 조치를 취할 수 있도록 하는 기술의 개발과 현장 적용이 요구된다.

  • PDF

Effect of Post-traumatic Stress and Ways of Stress Coping on Problem Drinking in Firefighters (남자소방공무원의 외상 후 스트레스와 대처방식이 문제음주에 미치는 영향)

  • Jeon, Kyoung-Sun;Kang, Kyung-Ah
    • Korean Journal of Occupational Health Nursing
    • /
    • v.26 no.4
    • /
    • pp.218-226
    • /
    • 2017
  • Purpose: The study aimed to determine the impact of post-traumatic stress and ways of stress coping on problem drinking in firefighters. Methods: Data were collected from May 11 to June 11, 2015, in fire brigades across South Korea. Participants were 183 male firefighters who used self-report questionnaires containing questions from the Impact of Event Scale-Revised (IES-R), Ways of Coping Checklist (WCC), and Alcohol Use Disorders Identification Test (AUDIT). Data were analyzed using $x^2$ test, t-test, and logistic regression with the SPSS/WIN 21.0 program. Results: The prevalence of PTSD among firefighters was 36.7% and that of problem drinking was 39.3%. Firefighters with single (OR=0.23, 95% CI=0.038~1.321) and married status (OR=0.46, 95% CI=0.069~3.040) were less likely to have problem drinking than those who were divorced or bereavement. Those with invasion symptoms (OR=1.17, 95% CI=1.031~1.327) and hyperarousal symptoms (OR=0.85, 95% CI=0.722~0.989) were more likely to have problem drinking than those with avoidance symptoms. Conclusion: Post-traumatic stress symptom was a major risk factor that increased problem drinking, and married status reduced problem drinking. There is a need to develop post-traumatic stress symptom management program and early education content for symptom management.

A Study on the Correlation among the Patterns of the Zone 1, 2, 3 of Factor AA in 7-Zone-Diagnostic System and the Clinical Parameters (7구역진단기의 Factor AA 제1, 2, 3구역 유형과 임상지표와의 상관성 연구)

  • Cho, Yi-Hyun;Yu, Jung-Suk;Lee, Hwi-Yong;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.25 no.6
    • /
    • pp.67-76
    • /
    • 2008
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 1, 2, 3 of Factor AA in CP-6000A(VEGA, Germany), 7-zone-diagnostic system and clinical parameters. The purpose of this study was relation Korean traditional medicine and western medicine with the data from 7-zone-diagnostic system and the clinical parameters. Methods : This study was carried out with the data from some clinical parameters. We made three groups according to the Factor AA patterns of CP-6000A. The Factor AA pattern of Group A is that the red bar graph of zone 1, 2, 3 were higher than the normal range and the others were the normal range. The Factor AA pattern of Group B was that the red bar graph of zone 1, 2, 3 was the normal range and the others were the normal range. The Factor AA pattern of Group C was that the red bar graph of zone 1, 2, 3 was lower than the normal range and the others were the normal range. After the data from clinical parameters to correspond with conditions of each group were selected, the data from clinical parameters among each groups analyzed statistically. Results : The values of GOT, GPT, r-GPT, Triglyceride, BUN, Uric acid of group A was higher than group C. Gastroscope of group A and B was higher than group C. Conclusions : It is thought that the red bar graph of zone 1, 2, 3 is higher, the group has the higher energy and the energy has a character of fire(熱). Those patterns have a high risk of hyperlipermia and liver, stomach disease.

  • PDF

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

Biorisk Assessment of Medical Diagnostic Laboratories in Nigeria

  • Oladeinde, Bankole Henry;Omoregie, Richard;Odia, Ikponmwonsa;Osakue, Eguagie Osareniro;Imade, Odaro Stanley
    • Safety and Health at Work
    • /
    • v.4 no.2
    • /
    • pp.100-104
    • /
    • 2013
  • Background: The aim of this study was to assess public and private medical diagnostic laboratories in Nigeria for the presence of biosafety equipment, devices, and measures. Methods: A total of 80 diagnostic laboratories in biosafety level 3 were assessed for the presence of biosafety equipment, devices, and compliance rate with biosafety practices. A detailed questionnaire and checklist was used to obtain the relevant information from enlisted laboratories. Results: The results showed the presence of an isolated unit for microbiological work, leak-proof working benches, self-closing doors, emergency exits, fire extinguisher(s), autoclaves, and hand washing sinks in 21.3%, 71.3%, 15.0%, 1.3%, 11.3%, 82.5%, and 67.5%, respectively, of all laboratories surveyed. It was observed that public diagnostic laboratories were significantly more likely to have an isolated unit for microbiological work (p = 0.001), hand washing sink (p = 0.003), and an autoclave ($p{\leq}0.001$) than private ones. Routine use of hand gloves, biosafety cabinet, and a first aid box was observed in 35.0%, 20.0%, and 2.5%, respectively, of all laboratories examined. Written standard operating procedures, biosafety manuals, and biohazard signs on door entrances were observed in 6.3%, 1.3%, and 3.8%, respectively, of all audited laboratories. No biosafety officer(s) or records of previous spills, or injuries and accidents, were observed in all diagnostic laboratories studied. Conclusion: In all laboratories (public and private) surveyed, marked deficiencies were observed in the area of administrative control responsible for implementing biosafety. Increased emphasis on provision of biosafety devices and compliance with standard codes of practices issued by relevant authorities is strongly advocated.

Using Workers' Compensation Claims Data to Describe Nonfatal Injuries among Workers in Alaska

  • Lucas, Devin L.;Lee, Jennifer R.;Moller, Kyle M.;O'Connor, Mary B.;Syron, Laura N.;Watson, Joanna R.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.165-172
    • /
    • 2020
  • Background: To gain a better understanding of nonfatal injuries in Alaska, underutilized data sources such as workers' compensation claims must be analyzed. The purpose of the current study was to utilize workers' compensation claims data to estimate the risk of nonfatal, work-related injuries among occupations in Alaska, characterize injury patterns, and prioritize future research. Methods: A dataset with information on all submitted claims during 2014-2015 was provided for analysis. Claims were manually reviewed and coded. For inclusion in this study, claims had to represent incidents that resulted in a nonfatal acute traumatic injury, occurred in Alaska during 2014-2015, and were approved for compensation. Results: Construction workers had the highest number of injuries (2,220), but a rate lower than the overall rate (34 per 1,000 construction workers, compared to 40 per 1,000 workers overall). Fire fighters had the highest rate of injuries on the job, with 162 injuries per 1,000 workers, followed by law enforcement officers with 121 injuries per 1,000 workers. The most common types of injuries across all occupations were sprains/strains/tears, contusions, and lacerations. Conclusion: The successful use of Alaska workers' compensation data demonstrates that the information provided in the claims dataset is meaningful for epidemiologic research. The predominance of sprains, strains, and tears among all occupations in Alaska indicates that ergonomic interventions to prevent overexertion are needed. These findings will be used to promote and guide future injury prevention research and interventions.

Study on Recycling Technology of Waste Artificial Marble using Starch (전분을 이용한 폐인조대리석의 재활용 기술에 관한 연구)

  • Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.6
    • /
    • pp.433-440
    • /
    • 2018
  • The pyrolysis has been universally applied to recycle the waste artificial marble. However, the existing heat treatment equipment has relatively low heat transfer efficiency into the inner part of the waste artificial marble. Besides, it leads to unnecessary excessive gas during the partial carbonization of the polymethyl methacrylate (PMMA) and raises the risk of fire due to heat at an extremely high temperature. This study suggests the process of pyrolysis at the formation state after adding the starch to waste artificial marble to overcome above-mentioned problems. As the result of experiments, this method showed that the pyrolysis of waste artificial marble was greatly improved at comparatively low temperature condition of $350^{\circ}C$. Moreover, it also manifested the effect on securing the stability and energy savings necessary for the recovery of methyl methacrylate (MMA) and ${\alpha}$-alumina (${\alpha}-Al_2O_3$).

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.