Smart CCTV Security Service in IoT(Internet of Things) Environment (사물인터넷 환경에서 스마트 CCTV 방범 서비스)

  • Cho, Jeong-Rae;Kim, Hye-Suk;Chae, Doo-Keol;Lim, Suk-Ja
    • Journal of Digital Contents Society
    • /
    • v.18 no.6
    • /
    • pp.1135-1142
    • /
    • 2017
  • In this paper, we propose IoT based smart CCTV security service to prevent crime in blind spot and prevent unexpected fire or danger. In the proposed method, a RC (Radio Control) car is made using Raspberry pie, and a camera and various modules are installed in an RC car. It was then implemented using Raspbian O / S, Apache Web Server, Shell script, Python, PHP, HTML, CSS, Javascript. The RC car provides a security service that informs the manager of the situation by judging the risk of the scene with modules such as video, voice and temperature. Experimental results show that the transmission time of video and audio information is less than 0.1 second. In addition, real-time status transmission was possible in AVG, emergency, and manual mode. It is expected that the proposed method will be applied to the development of smart city by applying it to unmanned vehicles, drones and the like.

A Study on application of F-N curve to OCA (장외영향평가 F-N curve 적용에 관한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.31-37
    • /
    • 2018
  • The distrust about chemical plant safety have been increased by occurring the major industrial accidents. Chemical plants have become more and more enlarged and sophisticated to increase production amount and decrease cost. So hazard of industrial accidents also have been increased. In this situation, quantitative risk assessment is activated by introducing OCA(Off-site Consequence Analysis). So it is possible to analyze the objective hazard of chemical plant. Currently OCA focus on the end point of hazardous area by fire/explosion/dispersion. But in this case, it is possible to analyze the industrial accident effect to near the chemical plant but hard to consider the actual hazard by frequency and population density. This study analyzes the validity about application of F-N curve to OCA by compare end point with F-N curve about accident.

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

The Research on the Development of Passenger Helmet to Prevent Head Trauma (두부 손상 보호를 위한 승객용 헬멧 개발 연구)

  • Lim, Jeong-Ku;Kweon, Ghi-Sun;Dodge, Robin E.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.18 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • Introduction : Head trauma is the main cause of death in aircraft crash. In a Michigan study of structurally survivable, fatal accidents, 80% of the fatally injured had received head trauma. We tried to develop a new helmet for passengers, and perform its efficiency test. Methods : An aircraft helmet requires an excellent protection against head trauma, lightness, and small volumes. In addition, it must be wearable, fire resistant, and non toxic when it is burning. We developed two new helmets made from silicone foam which met all theses requirements. One was thin (2.5cm), and the other was thick (6.3cm). These looked like a motorcycle helmet and had only a soft silicone as liner material without an outer hard shell. Therefore we can carry them easily inside aircrafts. The standard test for helmet is Snell's drop test. It measures the impact acceleration of head shaped metal wearing helmet during we drop it at certain heights. Impact sites were total 5 sites (front, back, right, left and top) for each helmet. All these sites were impacted twice. Results : The thickness of impact sites varied from 2.5cm to 6.3cm. The impact acceleration of 2.5cm thickness site when it was dropped from 1.0 meter was 379g. But, that of 6.3cm thickness site when it was dropped from 1.5 meter was only 163g. Unfortunately, both helmets didn't meet the Snell Standard for motorcycle helmets. Discussion : If we add suitable outer hard shell, and change its thickness and design, the efficiency will be increased. A study indicated that helmet could reduce the risk of head trauma up to 85%. We made helmet for passengers in aircraft crash for the first time. If we improve its weak points, it will decrease the frequency of head trauma in aircraft craft.

Problem Solving for LPG Storage Tank using RPS-TRIZ (RPS-TRIZ를 활용한 LPG 저장탱크 문제해결)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Lim, Ju-Yeon;Kim, In-Gyu;Jeong, Shin-Young
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.5
    • /
    • pp.7-12
    • /
    • 2011
  • LPG(Liquefied Petroluem Gas) Vehicles in metropolitan area being applied to improve air quality and have been proven effective for the reduction of air pollution. These gas stations are required to safe the storage tank because of possibility of causing huge loss of life and property. While storage tanks above ground have potential risk of explosion if fire breaks out and those under-ground are difficult to inspect due to poor accessibility neither above nor under-ground tank can serve us well. This study used the RPS-TRIZ (Rapidly Problem Solving-Teoriya Resheniya Izobretatelskikh Zadatch) technique and suggested the use of under-ground containment storage tank as a solution for safety issues and safety inspection.

A Study of Risk Reduction by SIL(Safety Integrity Level) Determination (SIL(Safety Integrity Level) 선택에 의한 리스크 감소에 관한 연구)

  • Kim, Jung-Hwan;Kim, Bum-Su;Yang, Jae-Mo;Jang, Chang-Bong;Kim, Min-Seop;Jung, Sang-Yong;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.5
    • /
    • pp.57-62
    • /
    • 2011
  • Modern chemical plants including petroleum refinery and gas industries have evolved into more complex and specialized. In these industrial complexes, it is important to maintain acceptable safety level protecting from various potential disasters caused by fire, explosion and the leakage of toxic materials. Recently possibility and consequence of accidents are increasing in the industrial process. So there is a trade-off between the plant operation efficiency and safety level. In this study SIF(Safety instrument Functions) was incorporated into SIL(Safety Integrity Levels). As a result, the safety level was upgraded by designing resonable allocation of safety instruments.

A simplified method for estimating the fundamental period of masonry infilled reinforced concrete frames

  • Jiang, Rui;Jiang, Liqiang;Hu, Yi;Ye, Jihong;Zhou, Lingyu
    • Structural Engineering and Mechanics
    • /
    • v.74 no.6
    • /
    • pp.821-832
    • /
    • 2020
  • The fundamental period is an important parameter for seismic design and seismic risk assessment of building structures. In this paper, a simplified theoretical method to predict the fundamental period of masonry infilled reinforced concrete (RC) frame is developed based on the basic theory of engineering mechanics. The different configurations of the RC frame as well as masonry walls were taken into account in the developed method. The fundamental period of the infilled structure is calculated according to the integration of the lateral stiffness of the RC frame and masonry walls along the height. A correction coefficient is considered to control the error for the period estimation, and it is determined according to the multiple linear regression analysis. The corrected formula is verified by shaking table tests on two masonry infilled RC frame models, and the errors between the estimated and test period are 2.3% and 23.2%. Finally, a probability-based method is proposed for the corrected formula, and it allows the structural engineers to select an appropriate fundamental period with a certain safety redundancy. The proposed method can be quickly and flexibly used for prediction, and it can be hand-calculated and easily understood. Thus it would be a good choice in determining the fundamental period of RC frames infilled with masonry wall structures in engineering practice instead of the existing methods.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

The Effects of Job Stress with Depression and Fatigue of Firemen (소방관의 직무스트레스가 우울 및 피로에 미치는 영향)

  • Kim, Kwang-Seok;Park, Jong;Park, Bu-Yeon;Kim, Sung-Gil;Hwang, Eun-Yeong
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.223-231
    • /
    • 2014
  • This study aims to identify job stress of firemen and the relations between their job stress, depression and fatigue, targeting firemen who are working for local fire stations. We interviewed the subjects using a short-answer type questionnaire or a online questionnaire. The data collected were analysed with a use of SPSS WIN 15.0 for confidence analysis, correlation analysis, step-by-step multi-regression analysis, and covariance structure analysis(CSA). This study result tasks and emotional stress had a direct effect on depression and fatigue. Therefore, this study suggests that governmental management should be provided for firemen that are classified as a high-risk group in occupational characteristics. Above all, the causes of stress should be diagnosed, its management goals should be set, and effective intervention programs should be provided.

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.