• Title/Summary/Keyword: fire retardant treated wood

Search Result 56, Processing Time 0.021 seconds

The Cause of Whitening by Flame Retardants Treatment on Korean Wooden Cultural Heritage

  • Kim, Jin Qyu;Chung, Yong Jae;Lee, Hwa Soo;Seo, Hyun Jeong;Son, Dong Won;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.589-599
    • /
    • 2016
  • Korean wooden cultural heritages are treated by flame retardants to protect fire hazards. Two types of flame retardants are used to treat wooden cultural heritage. These flame retardants cause some problems such as surface whitening, discoloration, and cracks due to the chemical reaction caused by Korean traditional wood painting (Dancheong), flame retardant and wood humidity. The Korean government is trying to cut down on the amount of flame retardants for the wooden cultural heritage because of these problems. This study was carried out to find the cause of whitening by flame retardants treatment. The reaction between pigment and flame retardant chemicals was analyzed by infrared spectroscopy.

Effects of Fire Retardant Treatment on Mechanical Properties and Fire Retardancy of Particleboard and Complyboard (내화처리(耐火處理)가 파아티클보오드와 콤플라이보오드의 기계적성질(機械的性質) 및 내화도(耐火度)에 미치는 영향(影響))

  • Kwon, Jin-Heon;Lee, Phll-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.3-57
    • /
    • 1985
  • This research was conducted to examine the feasibility of developing fire retardant particleboard and complyboard. Particleboard were manufactured using meranti particle(Shorea spp.)made with Pallmann chipper, and complyboard meranti particle and apitong veneer (Dipterocarpus spp.). Particles were passed through 4mm (6 mesh) and retained on 1mm (25 mesh). Urea formaldehyde resin was added 10 percent on ovendry weight of particle. Face veneer for complyboard was 0.9, 1.6 and 2.3mm in thickness and spread with 36 g/(30.48 cm)$^2$ glue on one side. Veneers were soaked with 10 percent solution of five fire retardant chemicals (diammonium phosphate, ammonium sulfate, monoammonium phosphate, Pyresote and Minalith), and particles with 5, 10, 15 and 20 percent solution of five chemicals. Particleboard and complyboard were evaluated on physical and mechanical properties, and fire retardancy. The results obtained were summarized as follows. 1. Among five fire retardant chemicals treated to particleboard and complyboard, the retention of ammonium sulfate in 5 percent solution showed the lowest as 1.39 kg/(30.48 cm)$^3$ exceeding the minimum retention of 1.125 kg/(30.48 cm)$^3$ recommended by Forest Products Laboratory and Koch. 2. Particleboard and complyboard treated with diammonium phosphate showed higher modulus of rupture (MOR), modulus of elasticity (MOE), internal bond strength and screw holding power than those with the other chemicals. 3. MOR and MOE of complyboard treated with fire retardant chemicals were greater than those of fire retardant particleboard. 4. Thickness swelling of fire retardant complyboard was lower than that of fire retardant particleboard. 5. The moisture content of the boards treated with Pyresote and Minalith increased and with monoammonium phosphate reduced. 6. Fire retardant particleboard showed no ignition, and fire retardant complyboard started ignition, but time required to ignite was prolonged comparing the controlboard. Complyboard with only shell veneer treated showed ignition and lingering flame, but lingering flame time was shorter than controlboard. Complyboard with treated both core and veneer showed ignition but not lingering flame. 7. Flame length, carbonized area and weight loss were smaller than controlboard but had no significant difference among chemicals treated. 8. Temperature of unexposed surface of fire retardant particleboard was lowered with the increasing concentration of five chemicals. 9. Temperature of unexposed surface of fire retardant particleboard was lowered with the highest in Pyresote and the lowest in Minalith. 10. Temperature of unexposed surface of fire retardant complyboard was lower than that of controlboard.

  • PDF

A Study on Combustion Characteristics of Flame Retardant Treated Pinus Densiflora (방염처리 육송의 연소특성 연구)

  • Choi, Jung-Min;Ro, Ho-Seung;Jin, Young-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.57-62
    • /
    • 2011
  • The combustion characteristic was evaluated for Pinus densiflora, used as a building material in Hanok, which were treated with two different flame retardant method. The specimen was brushed with flame retardant liquid two or three times and then let the specimen dehydrated during 24 h for spreaded treating. And the other specimen was soaked in the liquid for 72 h. The test methods were inflammability test using meker burner and heat release rate test using cone calorimeter. As a result for the tests, flame retardant treated specimens met the requirements of the inflammability and the spreaded treated method was more efficient than immersed method. The spreaded treated specimen had lower combustive properties than immersed specimen in TTI (time to ignition), PHRR (peak heat release rate), MLR (mass loss rate) and THR (total heat release).

Studies on the Residual Bending Strength of Burned Wood treated with Fire-retardant Chemicals (내화처리연소목(耐火處理燃燒木)의 잔류(殘留) 휨강도에 관(關)한 연구(硏究))

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.10-19
    • /
    • 1984
  • The $3{\times}3{\times}30$ ($cm^3$) sized lumbers of Populus alba-grandulosa L. were treated with four fire-retardant solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate and aluminium chloride for 1, 15, 30, and 60 minutes and 1, 3, and 7 days. Thereafter they were air-dried and burned at high temperature about $1,800^{\circ}C$ and for short time of five minutes. This study estimated the relationship between absorbed chemical amounts and rate of weight loss or residual bending strength of these burned lumbers. The results were as follows: 1) In absorption amount of fire-retardant chemicals, diammonium phosphate showed the largest, aluminium chloride the smallest, but monoammonium phosphate and ammonium sulfate showed similar level. 2) The absorption amount of chemicals was decreased with the increase of specific gravity in the same species except aluminium chloride. 3) The rate of weight loss was decreased as the absorption amount of chemicals increased, especially monoammonium phosphate was most effective. 4) The MOR value of the residual bending strength was increased as the absorption amount of chemicals increased and especially monoammonium phosphate showed the most efficient effect. 5) Aluminium chloride showed more striking increase of MOR value of residual bending strength with the increase of absorption amount than any other chemical, therefore its MOR value was similar to the maximum MOR value of the most effective monoammonium phosphate. 6) The correlation between weight loss and MOR value of the residual bending strength was negative and aluminium chloride showed the most striking negative relation, but the others showed similar trends. 7) The correlation between work to proportional limit and absorption amount of chemicals was positive and the degree of increase in work to proportional limit was most in aluminium chloride, and the next, in monoammonium phosphate and diammonium phosphate in turn. 8) The correlation between work to maximum load and absorption amount of chemicals showed positive and diammonium phosphate revealed the best result and aluminium chloride showed better results than other two chemicals.

  • PDF

A Comparative Study on the Mechanical Properties of Plywood treated with Several Fire-Retardant Chemicals(II) - Effect of Platen Temperature in Press Drying on the Static Bending Strength of Treated Plywood - (수종(樹種) 내화약제(耐火藥劑)로 처리(處理)된 합판(處理)의 기술적(技術的) 성질(性質)에 관(關)한 비교연구(比較硏究)(II) - 열판건조시(熱板乾燥時) 열판온도(熱板溫度)가 처리합판(處理合板)의 휨강도(强度)에 미치는 영향(影響) -)

  • Chung, Woo-Yang;Kim, Jong-Man;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.12-18
    • /
    • 1984
  • Soaking treated in 20% aqueous solutions of $(NH_4)_2SO_4$, $NH_4H_2PO_4$, $(NH_4)_2HPO_4$, $Na_2B_4O_7-H_3BO_3$(60:40) and Minalith, the mixed salts for 9 hrs. the wet 3.5mm meranti (Parashorea spp.) plywoods were press-dried at 90, 120 and $150^{\circ}C$ and put to static bending test to examine the influence of redrying temperature on the strength of fire-retardant treated plywoods ill flexure. While water-soaking treatment (control) showed serious reduction in Stress at proportional limit, MOE, MOR, Work per unit volume at $150^{\circ}C$, all the fire-retardant treatments maintained bending strength even at $150^{\circ}C$ and showed rather increased values in case of some chemicals. In view of drying rate and maintenance of strength, the most pertinent platen temperature was $150^{\circ}C$ and Borax-Boric acid was the predominant fire-retardant in this study.

  • PDF

Investigation about Flame-Retardant Performance Valuation Method of Wood treated by Flame-Retardant (방염처리된 목재의 방염성능평가방법에 대한 고찰)

  • Cha, Jeong-Min;Kim, In-Beom;Hyun, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.271-274
    • /
    • 2010
  • 방염대상물품의 방염성능을 평가함에 있어서 건축물의 내장재로 활용되어지는 목재의 경우 방염액 또는 방염필름 등을 활용한 직접적인 방염처리방법을 많이 활용하고 있는데 방염성능을 평가하는 기준으로는 잔염시간, 잔신시간, 탄화길이, 탄화면적 등의 수치가 기준을 만족하여야 하는데 목재를 활용한 합판에 적용되어지는 방염처리방법에 따라 성능기준의 모호성이 나타날 수 있기 때문에 방염성능의 적합여부를 판단하기 어려운 점이 있어 이에 대해 실험적으로 고찰한 결과를 살펴보았다.

  • PDF

Vacuum Pressure Treatment of Water-Soluble Melamine Resin Impregnation for Improvement of Mechanical Property, Abrasion Resistance and Incombustibility on Softwood (목재의 기계적 성질, 내마모성 및 난연성 개선을 위한 진공가압 멜라민 수지함침처리)

  • Oh, Seung-Won;Park, Hee Jun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.792-797
    • /
    • 2015
  • In this study, three softwood species were treated with water-soluble melamine resin by different concentration and treatment time under vacuum pressure for improving mechanical property, abrasion resistance, and incombustibility. After the treatment, a compreg was manufactured and then evaluated on physical properties. Additionally, incombustibility of compreg was determined by comparing with a wood that was treated by spraying a water-soluble fire retardant on surface. As concentration of resin increased, bending strength and Brinell hardness increased as well as abrasion resistance, but there was no correlation on treatment and mechanical properties by treatment time. The wood impregnated by water-soluble melamine resin under vacuum pressure showed better incombustibility than that of a water-soluble fire retardant sprayed wood. Therefore, this treatment could be used for improving incombustibility of wood.

Redrying Fire - Retardant - Treated Structural Plywood (구조용(構造用) 내화처리(耐火處理) 합판(合板)의 재건조(再乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Schaffer, E.L.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.1-21
    • /
    • 1981
  • Exterior grades of Douglas-fir and aspen plywood were impregnated with interior fire-retardant chemicals and redried under low-, intermediate-, and high-temperature drying conditions. Fire-retardant treatments included borax-boric acid, chromated zinc chloride, minalith, pyresote, and a commercial formulation. Drying processes included kiln and press-drying. Evaluated were drying rates and defects generated. The borax-boric acid and the commercial treatments redried at rates similar to water-treated controls. Other salt treatments were significantly slower drying and more defect prone. Chromated zinc chloride treatment was consistently the slowest drying and most defect prone. Press drying was three times faster at an equivalent temperature level. However, thickness shrinkage doubled because of 50 1b/in. platen pressure.

  • PDF

A Study on Emission Properties of Green House Gas on Duration Combustion of Constructive Wood Materials (건축용 목재의 연소시 지구온난화 가스의 배출특성에 관한 연구)

  • An, Hyung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.123-128
    • /
    • 2018
  • MDF was treated on the surface of MDF with fire retardant lacquer, water-soluble flame retardant coat and water-soluble wood cover on the MDF wood, and the pyrolysis characteristics and the atmospheric noxious gas generation characteristics were investigated by using the large capacity thermal analyzer. As a result of investigating pyrolysis and combustion gas generation characteristics after treatment of 0.11 / 11.55 g in terms of mass ratio, it was found that combustion starting time was slightly longer than that of pure MDF in the case of treatment with fire retardant lacquer. The combustion temperature was increased from $340^{\circ}C$ to $450^{\circ}C$. The pyrolysis and combustion gas generation characteristics of the MDF wood treated with the aqueous flame retardant coat showed the changes in combustion starting time and temperature from $260^{\circ}C$ to $542^{\circ}C$ for about 26 minutes at the mass ratio of 0.13 / 11g. Also, when the commercially available waterproof wood cover was treated with 0.13 / 11.55 g of MDF, the sudden weight change tended to increase from $300^{\circ}C$ to $370^{\circ}C$ and showed a second change at approximately $500^{\circ}C$.

The Combustion Gas Hazard Assessment of Main Building Materials (주요 건축 재료별 연소가스 유해성 평가)

  • Kim, Jong-Buk;Lee, Si-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.639-654
    • /
    • 2016
  • This study building materials by relates to human hazard assessment in accordance with the combustion gas SEM, the flame-retardant foam FTIR and cone calorimeter to configure the Forest products of MDF and preservative treated Lauan two kinds of Retardant styrofoam, Styrofoam, Urethane foam and gypsum board four kinds of plastics material by the combustion gas were each analyzed. MDF was burned to the structure of the wood and the glue evenly mixed combustion area preservative treated Lauan, kept constant even in the form of high heat to penetrate deep into the wood flame retardant agents. Retardant styrofoam is due to feed my Dropped dissolved inorganic flame retardant without the fire-stick and confirmed that the weak form of gypsum board, but keep the column. In MDF ammonia ($NH_3$), lethal concentration (750 ppm) compared to 795 ppm, preservative treated Lauan is carbon dioxide ($CO_2$) that was greater than 2.5 times the lethal concentration (100,000 ppm) to 256,965 ppm, the lethal concentration (500 ppm) of hydrogen chloride (HCl). The Urethane greater than 697 ppm, 434 ppm also greatly exceeding the nitrogen dioxide ($NO_2$) lethal concentration (250 ppm) in Retardant styrofoam and 398 ppm was released. It is confirmed that the human body is extremely harmful gas emitted from most of the materials to be utilized as basic data for evaluating the hazard-specific human future building material.