A Study on the Current Status and the Improvement Plan of Human Resource Development in Domestic Fire Industry (국내 소방산업 인력양성현황 및 개선에 관한 연구)

  • Shin, Mi-Young;Lee, Hae-Pyeong;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.173-180
    • /
    • 2009
  • As cities become recently more crowded, various and enlarged, it is required a cutting-edge technology for fire industry. According to this, a transition is attempted from production intensive industry toward knowledge based industry. At this point, in order to develop fire industry into knowledge based high value industry, industry innovation capability is required and it heavily depends on human resource competitiveness. Accordingly, in this study is aimed to look the status of domestic fire industry personnel training by classifying the fire industry manpower by field skill personnel, high technology personnel, and professional research personnel and to suggest problems with personnel training followed by each classification and how to improve them.

A Study on the Current Status and the Improvement Plan of Human Resource Development in Domestic Fire Protection Industry (국내 소방산업인력양성 현황 및 개선에 관한 연구)

  • Shin, Mi-Young;Lee, Hae-Pyeong;Chung, Do-Young
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.461-464
    • /
    • 2008
  • Plan of Human Resource Development is essential to strategically promote poor domestic fire protection industry and as a consequent to grow it to a high value added service industry. To foster fire protection industry, any reform will be needed to for a smooth supplies of work force by training customized high class work force. Consequently, In this study, We will investigate and analyze the status and problems of current domestic fire protection industry so that We can suggest the direction for a way to improve these.

  • PDF

Investigation of Potential Fire Hazard Resources of Bridges on National Routes by Field and Web-based Satellite (현장 및 실내조사를 통한 일반국도교량의 화재위험요소 분석)

  • Kim, Yongjae;Kim, Seungwon;Ann, Hojune;Kong, Jungsik;Park, Cheolwoo
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.105-115
    • /
    • 2017
  • PURPOSES : The occurrence of unexpected disasters, including fire events, increases as the road network becomes complicated and traffic volume increases. When a fire event occurs on and under bridges, the damage extensively influences direct damage to structures, vehicles, and human life and secondary socioeconomic issues owing to traffic blockage. This study investigated potential fire-hazard risks on bridges of the Korean national route road. METHODS : The investigation was conducted using field investigation and analysis with satellite pictures and road views from commercial websites and the Bridge Management System (BMS). From the filed investigation, various potential fire resources were identified. The satellite pictures and road views were helpful in measuring and recognizing conditions underneath bridges, stowage areas, etc. RESULTS : There are various potential fire resources underneath bridges such as piled agricultural products, parked petroleum tanks, construction equipment, and attached high-voltage cables. A total of 94.6% of bridges have underneath clearances of less than 15 m. A bridge underneath volume that can stow a potential fire hazard resource was $7,332m^3$ on average, and most bridges have about $4,000m^3$ of space. Based on the BMS data, the amounts of PSC and steel girders were 29% and 25%, respectively. CONCLUSIONS : It was found that the amount of stowed potential fire hazard resources was proportional to the underneath space of bridges. Most bridges have less than 15 m of vertical clearance that can be considered as a critical value for a bridge fire. The fire risk investigation results should be helpful for developing bridge fire-protection tools.

Visualization of wildfire based on FIRMS API (FIRMS API를 이용한 GIS기반 산불 확산정보의 시각화)

  • Lee, Byung Hyun;Son, Min Woo;Kim, Byung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.454-454
    • /
    • 2022
  • Residents near the fire site are more anxious as they rely only on media information and the government's evacuation order due to the lack of information to understand the progress of the wildfire. Therefore, in the event of a wildfire, we try to understand the inconvenience of not being able to know the progress of the fire and solve it. This makes it possible to check the progress of wildfires and the spread of debris using the system interface (API) and weather data of the thermal infrared satellite image data (NASA FIRMS, Fire Information for Resource Management System), and finally, the purpose of this study. The results are provided through the Web including GIS-based visualization to provide decision-making reference information for evacuation in the event of a forest fire from the perspective of residents.

  • PDF

Analyzing Spread Rate of Samcheok Forest Fire Broken out in 2000 Using GIS (GIS 응용(應用)에 의한 2000년(年) 삼척(三陟) 산불의 확산속도(擴散速度) 분석(分析))

  • Lee, Byung-Doo;Chung, Joo-Sang;Kim, Hyung-Ho;Lee, Si-Young
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.6
    • /
    • pp.781-787
    • /
    • 2001
  • The spread rate of forest fire was analyzed on Samcheok forest fire that broke out on April 7, 2000 in Kunduck-Myun, Samcheok-City, Kangwon-Province and lasted for about 9 days. The spatial database including topography, overstory species distribution, micro-climate, daily fire front lines for the area was built using GIS and the daily spread pattern was investigated to determine a multiple regression equation to estimate forest fire spread rate. The results of the investigation showed that, on the first day, the forest fire spreaded out extremely fast up to 12.3m/min at about 10 a.m. until noon. After that, the forest fire spread rate fluctuated and slowed down as low as below 1m/min and quenched on April 15. The daily area-based spread rate along the fire spread line got to the peak of about 5,700ha on April 11, of which spread rates were recorded as 2.84m/min in the first half and 1.10m/min in the second half. Also, it was found that slope aspect, wind velocity and % area distribution of Pinus densiflora are the major factors affecting the spread rate of forest fire in this area.

  • PDF

Study on the Improvement Operation of the Incident Command System (긴급구조통제단 운영 개선방안)

  • Chae, Jin;Bae, Young-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.128-137
    • /
    • 2019
  • The aim of this study was to suggest ways to improve the operation of the Incident Command System for an effective disaster response in the event of a major disaster. As a result of the study, at the 5% significance level, which affects the perception of the operation, the significant variables that influence the operation of the Incidence Command System were found to be securing the operating budget, cooperation of the related agencies, disaster resource support, and expert training. The relative influence of the variables on the operation of the Incident Command System was found to be in the order of expert training, cooperation of related organizations, disaster resource support, and securing of the operating budget.

A Study on the Fire Fighting General Index for Fire Fighting of Crowded Wooden Building Cultural Asset (군집 목조 건축문화재의 화재대응을 위한 소방방재 종합지수 연구)

  • Kwon, Heung-Soon;Lee, Jeong-Soo
    • Journal of architectural history
    • /
    • v.21 no.2
    • /
    • pp.37-52
    • /
    • 2012
  • This research has set up the fire fighting general index for Fire fighting of Crowded Wooden Building Cultural Asset which is composed of traditional wooden building instinct or complex. The results of this study are as follows. First, Fire fighting general index for crowded wooden building cultural asset, it is necessary to set fire fighting priority by considering fire risk and cultural asset characteristic and establish the system to cope with fire disaster in the most effective way by arranging facilities with restricted resource. Second, Fire risk is the index to draw fire and spread risk of cultural asset by applying index calculation processes such as fire load, burning velocity and ignition material spread characteristic to various aspects such as individual building and complex and combining their results. Cultural asset importance index consists of individual building evaluation, publicity security degree, area importance evaluation and historical landscape degree evaluation. Third, for each index combination process, weight of each index is drawn on the basis of AHP analysis result that is performed to the specialists of related fields. The formula to apply and combine it is prepared to apply the model to include meaning of each index and comparative importance degree.

Gold Recovery from Geumsan Concentrate Using Microwave-nitric Acid Leaching and Lead-fire Assay (마이크로웨이브-질산용출과 납-시금법을 이용한 금산정광으로부터 금 회수)

  • Lee, Jong-Ju;On, Hyun-Sung;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.113-126
    • /
    • 2019
  • This study aimed to effectively dissolve sulfide minerals through microwave-nitric acid leaching of invisible gold concentrate and then recover gold from the solid-residue with fire assay. For the purposes, this study conducted microwave-nitric acid leaching experiments to examine nitric acid concentration, time of microwave leaching, and sample addition effect. As results of the experiments, this study discovered that the weight loss rate of solid-residue increased as nitric acid concentration and microwave leaching time increased while weight loss rate decreased as sample addition increased. In an XRD analysis with solid-residue, it was discovered that pyrite completely disappeared when the nitric acid concentrate was 6 M and the microwave leaching time was 18 minutes. When a fire assay was carried out with solid-residue, gold particles with more content were recovered as nitric acid concentration and microwave leaching time increased whereas gold particles with more gold content were recovered as the sample addition decreased.