• Title/Summary/Keyword: fire rating

Search Result 103, Processing Time 0.031 seconds

Developing Forest Fire Occurrence Probability Model Using Meteorological Characteristics (기상자료(氣象資料)를 이용(利用)한 산불발생확률모형(發生確率模型)의 개발(開發))

  • Choi, Kwan;Han, Sang Yoel
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.1
    • /
    • pp.15-23
    • /
    • 1996
  • Preparing the era of forest resources management requires studies on forest fire. This study attempted to develop forest fire occurrence model using meteorological characteristics for the practical purposes of forecasting forest fire danger rate. To accomplish this goal, the relationships between forest fire occurrence and meteorological characteristics are estimated. In the process, the forest fire occurrence pattern of the study region(Taegu-Kyungpook) is categorized by employing qualification IV method. The study region was divided into three areas such as, Taegu, Andong and Pohang area. The meteorological variables emerged as affective to forest fire occurrence are relative humidity, longitude of sunshine, and duration of precipitation. To estimate the probability of forest fire danger, forest fire occurrence of three areas are regressed on the time series data of affective meteorological variables using logistic and probit model. The effectiveness of the models estimated are tested and showed acceptable degree of goodness. Those models developed would be helpful to increase the efficiency of forest fire management such as detection of forest fire occurrence and effective disposition of forest fire fight equipments.

  • PDF

An Analysis of the importance in fire-stations' works and redesign by disaster management steps (재난관리 단계별 소방업무 중요도분석 및 업무재설계)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.572-582
    • /
    • 2014
  • Fire-stations' works limited to the existing fire protection rescue and emergency services in rapidly changing disaster environment are not difficult to deal with the fire service demand of the people any longer. In this study, after calculating the importance of the disaster management about fire-stations' works by disaster management steps thorough a survey of experts about Fire and Disaster, firefighting tasks are to be redesigned. Experts have the higher rating in preparation step of firefighting tasks. Because securing resources and building systems in preparation step and safety training in prevention step have a high importance, it is required to improve efficiency of firefighting tasks through redesign. The most important point in redesign is to realize fire-stations' works are to expand and to develop such a policy if fire-offices excavate the civil and government cooperation works and provide such legal and institutional basis of establishment and operation. And it should be sought to maintain international cooperation for international disaster response. Ultimately, fire-offices will have further expansion in quality and simultaneously quantitatively by excavating 'collaboration (business cooperation)' or enhancing existing works in addition to existing 'fire and rescue, first aid' business.

A Study on the Development of Forest Fire Occurrence Probability Model using Canadian Forest Fire Weather Index -Occurrence of Forest Fire in Kangwon Province- (캐나다 산불 기상지수를 이용한 산불발생확률모형 개발 -강원도 지역 산불발생을 중심으로-)

  • Park, Houng-Sek;Lee, Si-Young;Chae, Hee-Mun;Lee, Woo-Kyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.95-100
    • /
    • 2009
  • Fine fuel moisture code (FFMC), a main component of forest fire weather index(FWI) in the Canadian forest fire danger rating system(CFFDRS), indicated a probability of ignition through expecting a dryness of fine fuels. According to this code, a rising of temperature and wind velocity, a decreasing of precipitation and decline of humidity in a weather condition showed a rising of a danger rate for the forest fire. In this study, we analyzed a weather condition during 5 years in Kangwon province, calculated a FFMC and examined an application of FFMC. Very low humidity and little precipitation was a characteristic during spring and fall fire season in Kangwon province. 75% of forest fires during 5 years occurred in this season and especially 90% of forest fire during fire season occurred in spring. For developing of the prediction model for a forest fire occurrence probability, we used a logistic regression function with forest fire occurrence data and classified mean FFMC during 10 days. Accuracy of a developed model was 63.6%. To improve this model, we need to deal with more meteorological data during overall seasons and to associate a meteorological condition with a forest fire occurrence with more research results.

A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting (자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han;Han, Sang-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.199-206
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

Safety Index of Korean Society Analyzed by Time Series (시계열로 분석한 한국사회의 사회안전지표)

  • Shin, Chang-Sub;Kim, Sung-Min;Hwang, Suk-Keun;Lee, Kyoung-Duck;Yee, Jae-Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.55-63
    • /
    • 2006
  • Rapid economic growth in Korea, on the other side, has generated increase of multiple complex dangers. To take off dangers scattered in the Korean society and to conduct safe society for better life, it is needed to develop social safety index. Social safety index analyzed by time series could compare and estimate various social disasters, thus it act as the foundation to set up safety policy. The research has focused on 8 social safety indexes; natural disaster, fire, traffic accident, crime, industry accident, forest fire, collapse and explosion, and environmental pollution. To find out Korean society safety index analyzed by time series, the research analyzed changes of each safety indexes in 10 years since 1994. Looking at the changes of each indexes, traffic accident showed the most improvement overall the nation, with industrial accident and collapse and explosion rating second and third place. However, crime, fire and natural disaster get worse, and especially crime has turned worsened than any other divisions.

Comparative Analysis of Forest Fire Danger Rating on Forest Characteristics of Thinning Area and Non-thinning Area on Forest Fire Burnt Area (산불적지에서 숲 가꾸기 실행 유무와 산불위험성 비교 분석)

  • Lee, Si-Young;Lee, Myung-Woog;Yeom, Chan-Ho;Kwon, Chun-Geun;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.32-39
    • /
    • 2009
  • In this study, 18 plots were selected for particular investigation on Gangneung area and Samcheok area and Uljin area, where forest fire was occurred after thinning in 2007. After selection, a relationship between a damage of forest fire and thinning were compared and analyzed. Many factor such as a damaged species, a thinning or non-thinning, a direction of forest fire head, DBH, a height of tree, a mortality of tree, a leeward scorching ratio, a crown damage ratio, a forest tree standing crop density, a crown base height, a leaving of thinning slash, a location of plot (GPS), elevation, an aspect of slope, an angle of slope, and a topography were measured. Therefore, we analyzed a relationship with forest fire. In the result of this analysis, it was founded that the leeward scorching ratio was 24.7% on thinning area whereas 60.2% on non-thinning area. Subsequently, leeward scorching ratio on thinning area was increased by about 35.5% more than on non-thinning area. In the result of analysis about tree species, a forest of pine tree was more damaged than forest of oak tree. The mortality of tree was increased by about 41.4% on non-thinning area. When stands were close to thinning slashes, these were more damaged by 10${\sim}$20% than other stands for increasing of amount of a combustion material. Especially, as potential of re-ignition increased for more cumulated thinning slash, it will be more important to require a method for a periodical removing or practical utilization of slash.

Comparative Analysis of Forest Fire Danger Rating on Accumulation Types of the Leaving of Thinning Slash (숲가꾸기 산물의 적재형태에 따른 산불위험성 비교 분석)

  • Lee, Si-Young;Lee, Myung-Woog;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • The effect of thinned trees which are produced from forest thinning on forest fire was studied in this work. To investigate the effect of thinning slash, Yang-yang, In-je, and Ga-pyeong-gun were selected as thinning-areas and non-thinning areas. The research was carried out with the variations of tree's types, area's characteristics, thinning strength, thinning types, and pile types of thinned tree. The survey areas of 14 areas were selected at Yangyang-gun(5 areas), Gapyeong-gun(4 areas), and Inje-gun(5 areas), and on-the-spot investigations were carried out at the thinning areas of 9 and the non-thinning areas of 5, respectively. Non-thinning areas of 5, which are adjacent to thinning areas, were selected for the comparison with thinning areas and for the analysis of risk of forest fire. It is considered that forest fire have no chance to diffuse to a tree trunk because the height of thinned trees was lower than 1 m. However, it is considered that forest fire may affect directly to a tree trunk if it spread to piled thinned tree because there was no space between thinned trees and trees. Furthermore, it was found that re-ignition had a chance to occur due to lots of piled thinning trees.

Development of the Judgment Method of the Occupational Safety & Health Management System for Small & Medium Enterprises (중소규모 사업장용 안전보건경영시스템의 인증 심사방법 개발)

  • Jang, Seo-Il;Ha, Jeong-Ho;Lyu, Bo-Hyuk;Kwon, Hyuck-Myun;Kim, Tae-Ok
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.3
    • /
    • pp.1-9
    • /
    • 2009
  • The present management of the domestic and international advanced enterprises is transferring the systems and the regulations to the prevention system management. Expecially, KOSHA (Korea Occupational Safety & Health Agency) in Korea has supported to set up the OSHMS (Occupational Safety & Health Management System) by KOSHA 18001 since 1997. But small & medium enterprises (SMS) has many difficulties to set up the OSHMS system because of limited natural and human resources. In this study, the rating system as a judgment method of an OSHMS based on the certification standard of the OSHMS, which was suggested in previous study, was developed for SMS to adopt voluntarily the OSHMS, certify KOSHA 18001, and improve the safety and health level.

A Research on Thermal Properties & Fire Resistance of A Water Film Covered Glazing System for Large Atrium Space (대규모 아트리움에 적용되는 수박형성 유리벽의 열적 특성 및 내화성능에 관한 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.38-55
    • /
    • 1999
  • In order practically to use fire-defective glazing materials for the compartment wall where a fire-protection rating is mandated, there have been many trials internationally, This research focuses on a feasibility that, if certain water film covered all surface of glass, the glazing system can endure without breaking out under the compartment fire. First of all, a water film spray system was specially designed to wet the entire surface of the glass and also to have tiny small amount of water rebounded from the surface after emitted from nozzles. After this system has proven to have perfect performance, small-scale tests were done to find out if the water film covered glazing system react to the high temperature curve in a small furnace room. Finally, on basis of the obtained data, full-scale experiments were done so that water-film covered glazing system can pass the Korean Standard (KS) test for fire resistance, KS F2257.

  • PDF

Study on the Weight Reduction of Firefighter's Protective Clothing by Using Air Layer and Aerogels (공기층과 에어로젤을 이용한 특수방화복 경량화 연구)

  • Kim, Hae-Hyoung;Park, Pyoung-Kyu;Kim, Young-Soo;Hong, Seung-Tae
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.81-88
    • /
    • 2018
  • Air and ultra lightweight aerogels were used to lighten the weight of the firefighters' protective clothing. In order to lighten the firefighters' protective clothing composed of 3 layers (outer shell, mid-layer, lining), it was most effective to replace the lining which occupied the largest weight in the total weight with the new materials. Thermal protective performance tests were carried out on flame (ASTM D 4108), radiant heat (KS K ISO 6942) and mixing heat (KS K ISO 17492) of flame and radiation. When the lining felt was replaced with an air layer, the air layer must be at least 3 mm to meet the KFI and ISO standards for the thermal protective performance. However, even if the thickness of the air layer increased to 10 mm, the thermal protective performance was lower than that of the existing products. When the felt was replaced with aerogels, the TPP rating (ASTM D 4108) satisfied the KFI standard at the 2 mm thickness of the aerogels. When the thickness of the aerogels was 3 mm, the TPP rating was improved about 140% compared to the existing products. It was confirmed that not only weight reduction but also thermal protective performance was improved by use of aerogels. However, due to the fragile nature of aerogels, a method of fixing them to a constant thickness between layers constituting a firefighters' protective clothing should be considered in the future.