Abstract
The effect of thinned trees which are produced from forest thinning on forest fire was studied in this work. To investigate the effect of thinning slash, Yang-yang, In-je, and Ga-pyeong-gun were selected as thinning-areas and non-thinning areas. The research was carried out with the variations of tree's types, area's characteristics, thinning strength, thinning types, and pile types of thinned tree. The survey areas of 14 areas were selected at Yangyang-gun(5 areas), Gapyeong-gun(4 areas), and Inje-gun(5 areas), and on-the-spot investigations were carried out at the thinning areas of 9 and the non-thinning areas of 5, respectively. Non-thinning areas of 5, which are adjacent to thinning areas, were selected for the comparison with thinning areas and for the analysis of risk of forest fire. It is considered that forest fire have no chance to diffuse to a tree trunk because the height of thinned trees was lower than 1 m. However, it is considered that forest fire may affect directly to a tree trunk if it spread to piled thinned tree because there was no space between thinned trees and trees. Furthermore, it was found that re-ignition had a chance to occur due to lots of piled thinning trees.
Keywords
Forest fire; Thinning slash; Pile types of thinned tree; Risk of forest fire;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Wayne H. Koski, William C. Fischer, "Photo Series for Appraising Thinning Slash in North IDAHO", USDA International Forest and Range Experiment Station, pp.1-49(1979)
2 USDA, "An Agency Strategy for Fire Management", http://www.fs.fed.us/fire/planning/USDA_Report. pdf, pp.1-27(2000)
3 Josep D. Lowe, "Wildland Firefighting Practics", Delmar, pp.27-30(2001)
4 News Rural Fire Service, "Application instructions for a Bush Fire Hazards Reduction Certificate", pp.1-11(2006)
5 국립 산림과학원, "지속가능한 산림자원관리 표준매 뉴얼", pp.17-32(2005)
6 이시영, 이해평, "한국의 산불발생 실태분석", 한국소방학회지, Vol.20, No.2, pp.54-63(2006)   과학기술학회마을
7 USDA, "Policy Implication of Large Fire Management: A Strategic Assessment of Factors Influencing Costs", http://www.fs.fed.us/fire/planning/Large_Fire_ Mgt.pdf(2000)
8 산림청, "임업통계연보", 제35호, pp.204-223(2004)
9 News Rural Fire Service, "Standards for Pile Burning", pp.1-4(2006)
10 News Rural Fire Service, "Standards for Asset Protection Zones", pp.1-11(2006)
11 산림청, "숲가꾸기 5개년 추진계획", pp.1-3(2003)