• Title/Summary/Keyword: fire protection system

Search Result 566, Processing Time 0.029 seconds

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.

A Study on the Possibility of using Light-Wall Stainless Steel Pipe for Water-Based Fire Protection System (수계소화설비용 경량벽 스테인리스 강관의 사용가능성 평가에 관한 연구)

  • Nam, Jun-Seok;Won, Sung-Yeun;Kim, Yong-Ho;Min, Kyung-Tak;Park, Seung-Min
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.94-101
    • /
    • 2010
  • The pipes using in water-based fire protection systems are used steel pipes for ordinary piping, carbon steel pipes for pressure service, copper and copper alloy seamless pipes and tubes, etc. By last buildings of high-rising, complexity, in fire protection systems, the corrosion resistance, easy construction, lightweight and cost-effective use of the pipes is being considered. Among the pipes, the possibility of used for fire protection system being used in the existing copper pipe of material properties, strength, corrosion resistance, heat resistance through and compare the performance was evaluated. As a result of that assessment light gauge stainless steel pipes for ordinary piping (KS D 3595) at a water pressure of less than 1.2 MPa can be used in sufficient physical properties, strength, corrosion resistance, heat resistance and have been observed.

내화설계의 성능규정화 추세에 관한 연구

  • Kim, Yeon-Gu;Park, Seung-In
    • Fire Protection Technology
    • /
    • s.28
    • /
    • pp.30-36
    • /
    • 2000
  • This manuscript is based on the report "THE RESEARCH ON THE OBJECT TO BE FIRE RESISTIVE AND THOSE LIMITS" issued by FILK. With advancement of the life style recently. People seek for more comfort therefore the aspect of the residence is getting more complex. Meanwhile, the vital and property loss caused fire is getting higher. For the safe of the public welfare, these fire hazard should be controlled by governmental system. It will also be satisfactory if this small opinion could be helpful for the safe.

  • PDF

FIRE PROTECTION FOR PETROCHEMICAL PLANT

  • Suh, Jung-H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.244-251
    • /
    • 1997
  • Since 1970s, The Petrochemical Industry in Korea has grown rapidly by the successful economic growth. While the process became larger and more complex, hazardous chemicals have been used in large quantity, Therefore, the risk of a major accident such as fire, explosion and toxic material release has been increased. Korea has been ranked the fifth in petrochemical product capacity worldwide, also required to meet international standards on process safety management. Fire Protection System integral part of safely management in Petrochemical Plants, will be reviewed.

  • PDF

The Study on the Fire Safety Plans by a Field the Actual Condition Analysis of Traditional Temples - With Special Reference to Eunpyeonggu Seoul - (전통사찰의 현장실태분석을 통한 소방안전대책에 관한 연구 - 서울특별시 은평구를 중심으로 -)

  • Song, Yun-Suk;Hyun, Seong-Ho;Kim, Wan-Seop
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.137-147
    • /
    • 2008
  • This study has investigated fire safety rules related with traditional temples and main fire causes and cases to traditional temples among traditional wooden buildings so has analyzed fire vulnerability, and through a field probe of three traditional temples in Eunpyeonggu Seoul which have cultural properties, has analyzed geographical conditions, going out path spot reaching time required of a fire brigade, fire protection system, fire prevention administration and security system, factors of fire vulnerability, and has presented about fire safety plans of traditional temples.

Trends of Onboard Fire Extinguishing System (선박용 소화설비의 국제동향)

  • Kim, Mann-Eung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.126-127
    • /
    • 2005
  • This paper provides information on the current issues and the progress of on-going researches relating onboard fixed fire extinguishing system in the IMO Sub-committee on Fire Protection. And also prepares to introduce the recent amendment to regulations and technical trends of the water mist fire extinguishing system and high expansion foam system.

  • PDF

Performance-based Fire Protection Design of Domestic Super High-rise Buildings - Evaluation by ASET and RSET -

  • Roh, Hyeong-Ki
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.9-13
    • /
    • 2011
  • The Performance-based fire protection design required to construct super high-rise building is the active measure for the evaluation of fire risks and the establishment of fire protection systems on the basis of engineering analysis, which is more efficient and proper than existing prescriptive-based design. This study applied time-line analysis of RSET is required safe egress time and ASET is available safe egress time with the fire and evacuation simulation to analyze. The result of this study showed the sprinkler system increased ASET and fire detection and alarm system reduced RSET efficiently. Reduced evacuation time influences to secure the life safety. Also it is essential to maintain the fire suppression system and fire detection & alarm system properly. Database of fire movement and evacuation action program are useful for the performance-based design.

NEW TREND OF FIRE SCIENCE AND EIRE PROTECTION TECHNOLOGY

  • Sugahara, Shinichi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.19-26
    • /
    • 1997
  • Firesafety design engineerings have been mainly derived from complicated rearrangement of descriptive specifications in codes or regulations through a great number of lessons from fire disasters. In this paper, the author refers to some recent developments in the field of building fire protection. At first, the author expresses his viewpoints concerning performance-based design codes, which have been popular throughout the world as a symbol of freedom from restricted usage of building materials and components prescrived in regulation or bylaws, in spite of some conflicts between objects-oriented design method and industrial mass production. Secondly, the author introduces several innovative fire protection methods adopted for large or void spaces in building complex. Finally, the author forcasts a next development of firesafety science and technology, aimed at securing personal safety in hyperscale urban areas.

  • PDF

A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test (중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구)

  • Min, Se-Hong;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.