• Title/Summary/Keyword: fire protection industry

Search Result 102, Processing Time 0.026 seconds

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

Chemical Use and Associated Health Concerns in the Semiconductor Manufacturing Industry

  • Yoon, Chungsik;Kim, Sunju;Park, Donguk;Choi, Younsoon;Jo, Jihoon;Lee, Kwonseob
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.500-508
    • /
    • 2020
  • Background: Research on the status of many chemicals used in the semiconductor industry is needed. The purpose of this study was to describe the overall status of chemical use in the semiconductor industry in Korea and to examine it from a health perspective. Methods: Data on the status of chemical use and safety data sheets at 11 of 12 major semiconductor workplaces in Korea were collected. The number of chemical products and chemical constituents, quantities of chemicals, and trade secret ingredients used, as well as the health hazards were examined. Results: On average, 210 chemical products and 135 chemical constituents were used at the surveyed workplaces. Among all chemical products, 33% (range: 16-56%) contained at least one trade secret ingredient. Most of the trade secret ingredients were used in the photolithography process. Several carcinogens, including sulfuric acid, chromic acid, ethylene oxide, crystalline silica, potassium dichromate, and formaldehyde were also used. Only 29% (39 of 135) of the chemical constituents had occupational exposure limits, and more than 60% had no National Fire Protection Association health, safety, and reactivity ratings. Based on the aforementioned results, this study revealed the following. First, many chemical products and constituents are being used in the semiconductor industry and many products contained trade secret ingredients. Second, many products contained significant amounts of carcinogenic, mutagenic, and reproductive toxicant materials. Conclusion: We conclude that protecting workers in the semiconductor industry against harm from chemical substances will be difficult, due to widespread use of trade secret ingredients and a lack of hazard information. The findings of the status of chemical use and the health and safety risks in semiconductor industry will contribute to epidemiological studies, safe workplace, and worker health protection.

The Measurement of the Explosion Limit and the Minimum Oxygen Concentration of Gasoline According to Variation in Octane Number (옥탄가 변화에 따른 가솔린의 폭발한계 및 최소산소농도 측정)

  • Kim, Won-Kil;Kim, Jung-Hun;Ryu, Jong-Woo;Choi, Jae-Wook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.618-622
    • /
    • 2017
  • Gasoline is a widely used product as a source for energy in homes, the automotive industry, and for industrial power generation, and it is also a product with a high risk of fire and explosion. In this study, to examine the risk for explosion for gasoline, PG, MG and RG, which are categorized according to octane number, were used as test specimens to measure their explosion limit according changes in oxygen concentration. The explosion limit for 21% oxygen concentration in air were confirmed to be 1.5~10.9%, 1.4~8.1%, and 1.3~7.6%, respectively, and the MOC for each of the test sample were confirmed to be 10.9%. The explosion limit measured in the test performed in this study confirmed between a 1.2%~7.6% wider explosion limit for the currently accepted MSDS for gasoline, and therefore it is considered that the results of this study can provide significant reference for preventing fires and explosions for process used gasoline.

Evaluation of Firefighting Gloves and the Behavior Regarding their Usage, of Firefighting Officials in Seoul (서울시 소방공무원의 방화장갑에 대한 평가 및 사용실태)

  • Kim, Do-Hee;Nam, Kibum;Oh, Jung-Woo;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.23 no.4
    • /
    • pp.515-526
    • /
    • 2021
  • This study aimed to investigate the evaluation of firefighting gloves and the behavior regarding their usage, of firefighting officials in Seoul, using a questionnaire. Responses from a total of 270 firefighters who are responsible for putting out fires or undertaking rescue works in Seoul were analyzed. As per the findings, the firefighters considered ease of hand operation and fire/flame protection as the most important performance factors for firefighting gloves, and they were satisfied with the supply status of the gloves. The average number of firefighting gloves currently owned by the firefighters was 2.6 ± 0.8 pairs. Thirty-nine percent of the respondents said that their firefighting gloves lasted, with maintained performance, for more than six months and less than a year, and when asked how they handled the gloves with degraded performance, 46% of them said that they would discard them. Sixty-eight percent of the respondents said that they used the most recently developed and supplied gloves, which they considered as the most satisfying gloves and which they mainly used these days. Respondents were highly satisfied with the fire/flame protection performance of their firefighting gloves, but were less satisfied, however, with the glove fit. These results suggest that there has been a significant improvement in the overall performance level and supply status of the firefighting gloves. Given the current situation, careful considerations with flexible approaches are needed on the current firefighting gloves size system as well as on the personal protective equipment maintenance and management scheme.

RSET Analysis According to the Width of Escape Routes in Large Supermarkets (대형마트의 피난로 폭에 따른 RSET 분석)

  • Boohyun Baek;Hongsang Lee;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.29-38
    • /
    • 2024
  • The purpose of this study is to use an evacuation simulation program to measure the change in evacuation time according to the width of the evacuation route due to the installation of an intermediate sales counter and the placement of a shopping cart between the sales counters of a large supermarket and to analyze the results. Currently, the "Distribution Industry Development Act" does not regulate the size and installation method of intermediate sales counters installed between sales counters that serve as practical evacuation routes in the event of a fire at a large supermarket, the size of shopping carts, etc. Considering this, we set evacuation route widths of 40, 50, 60, 70, 80, and 100 cm and compared and analyzed evacuation times according to various variables in the facility space. As a result of the experiment, as the width of the evacuation route was expanded, there was a significant difference in the evacuation time, from a maximum of 468.3 seconds to a minimum of 320.8 seconds. Considering the safety of evacuees in large supermarkets used by many people, it is time to regulate the size of intermediate sales stands installed between sales counters in large supermarkets and shopping carts that can become obstacles in an emergency.

A Study on the Correlation Between Job Satisfaction and Organizational Commitment of Firefighters (소방공무원의 직무만족과 조직몰입의 상관관계에 관한 연구)

  • Hyun-Mi Kim;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.665-674
    • /
    • 2024
  • This study attempted to examine the relationship between organizational satisfaction and organizational commitment of firefighters. As for the overall level job-only and organizational commitment, the average was3.80points and 3.49points(out of 5points), respectively, and among the items of organizational satisfaction, 'I believe I should be held accountable for the results of my work.' was the highest, 'I think I chose a good job as a firefighter.' was the highest in the items of organizational commitment. The higher the class, the higher the job satisfaction and organizational commitment satisfaction, and there was a statistically significant difference(p<.01). Based on this study, it is considered that expanded research and repeated are necessary to generalize the results of the effect of .organizational satisfaction of firefighters I on organizational commitment.

Improvement Plan for Safety Management of the Transport of Railway Dangerous Goods (철도 위험물 수송 안전관리제도 개선 방안)

  • Sung-Bong Chung;Bong-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.885-895
    • /
    • 2024
  • As the lack of management for HAZMAT transportation leads to fatal accidents, the interest in the problem is rapidly increasing in the world. Thus UN-RTDG recommends to establish regulations for HAZMAT transportation, and related ministries in Korea make rules and policies according to the regulations. However, there are few researches carried out on railway HAZMAT transportation. In this paper, issues such as present condition of laws and policies related to railway HAZMAT transportation, HAZMAT transportation procedure and regulations, HAZMAT signs of railway etc. are analyzed. Through analyzing these issues the problems and improvements of railway HAZMAT transportation are drawn. These results are respected to help to establish regulations and policies for HAZMAT transportation management. In the future, more detailed plan is needed for putting these improvements to practices.

Employment Adjustment in the British Shipbuilding Industry(1860~1945) - Focusing on the Case of the Boilermakers' Society (영국 조선산업의 고용조정(1860~1945): 보일러제조공조합을 중심으로)

  • Shin, Wonchul
    • Korean Journal of Labor Studies
    • /
    • v.24 no.2
    • /
    • pp.321-365
    • /
    • 2018
  • Though the British shipbuilding industry dominated the world market in the 19th century, it could not avoid the repetitive rise and fall of the unemployment following after the cyclical fluctuations. Without challenging the employers' rights to fire at will, the boilermakers maintained their own unemployment insurance in order to escape from the new poverty law system. In the beginning the craft union could continue their own unemployment insurance under the National Insurance Act of 1911, but it went into bankruptcy under the massive unemployment of the 1920s and the attacks of shipyard employers. The Act of 1911 was a step towards social solidarity in that it spread the risks beyond the occupational boundaries, applying unemployment insurance to unskilled and non-union workers, and the employer and the government also paid the premium. In the Great Depression, the shipyard trade unions demanded that the government should intervene in the shipbuilding market to provide jobs, but it was not accepted by the government. The government responded only to the another demand of the union for the maintenance, which could be achieved partially through the abnormal operation of the insurance system, abandoning the insurance principle. After all, unemployment in the shipbuilding industry was resolved only by the expansion of rearmaments and the outbreak of World War II. From the 19th century to the World War II, the craft unions did not challenge the employers' right to fire at will and did not attempt to regulate dismissal procedures or make any demands on dismissal compensations. During interwar periods rules and practices related with weak employment protection - one of the main features of the liberal employment adjustment institution - were prevalent in Britain. The principle of 'employment at will' could survive through the historical events such as the World War I, II as the operation of the unemployment insurance became the focus of the social conflicts.

A Comparison Analysis of Life Cycle Cost (LCC) of Pumps - In the Focus on Comparison of Excellent and General Products in Water Industry - (Pump의 생애주기 비용(LCC) 비교 분석 - 물산업 우수제품과 일반제품의 비교를 중심으로 -)

  • Park, Woopyung;Choi, Yong;Jeon, Si Young;Kim, Jinho;Kang, Seongmi
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.3
    • /
    • pp.66-73
    • /
    • 2022
  • In order to induce users to purchase excellent products in the water industry that satisfy the technical standards of excellent products, in this study, it is to present the advantages of the cost aspect of the pumps as the objective basis. It will be to promote technology development of domestic water companies and to create a virtuous cycle structure in the water industry. In order to present an objective basis for the merits in terms of cost, an economic evaluation was conducted through life cycle cost analysis. For the LCC analysis, initial cost (pump cost and installation cost), operation cost (energy cost and maintenance cost) and demolition cost (disposal cost and residual value) are searched and calculated. As the results of comparison on two capacity of pumps, the energy cost of the excellent pump is 212 million KRW lower than the that of general pump in the large pump. The cost of excellent pump was 17 million KRW lower than that of general pump in small capacity pump. As the results of sensibility test, if the product is developed in the direction of improving pump efficiency and increasing the replacement cycle of consumables, it is predicted that the effect on LCC will be large.

A Study for Safety Management on Road Transportation of Dangerous Goods (도로운송 위험물의 안전관리에 관한 개선 연구)

  • Lee, Bong-Woo;Chung, Sung-Bong;Kim, So-Young;Choi, Dong-Hwang
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.73-82
    • /
    • 2013
  • With remarkable development of industry and technology, various chemical articles are developed to improve the quality of human life, yet some of chemicals are hazardous to human and the environment. However, safety control of chemical articles such as transportation, storage, and handling is emerging as a major issue lately. The road transportation needs well-organized safety management system, especially it has high probability of accidents. In this research, we point out problems in current state and related regulation of transportation of dangerous goods to compare the regulation in UN-RTDG. In addition, we suggest the enhancement law, the plan for standardization of classification in road transportation of dangerous goods and harmonization of labeling in transportation of dangerous goods to contribute to human health and environment protection.