• Title/Summary/Keyword: fire period

Search Result 432, Processing Time 0.026 seconds

The model development and verification for surface branch wood fuels moisture prediction after precipitation during spring period at the east coast region (영동지역 봄철 소나무림에서 강우후 지표연료 직경별 연료습도변화 예측모델 개발 및 검증)

  • Lee, Si-Young;Lee, Myung-Woog;Kwon, Chun-Geun;Yeom, Chan-Ho;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.434-437
    • /
    • 2008
  • In this study, we developed a fuel moisture variation prediction model on each day after precipitation during a spring forest fire exhibition period. For this research, we selected plots in pine forest on Sam-Chuck si and Dong-hae si in Kangwon do according to a forest density(low, mediate, high) and classified a surface woody fuel by a diameter.(below 0.6cm, $0.6{\sim}3cm$, $3{\sim}6cm$, and above 6cm). A validity of this model was verified by applying a fuel moisture variation after precipitation in this spring. In the result, $R^2$ was $0.76{\sim}0.92$. This model will be a useful for improvement of a forest fire danger rate forcast through a prediction a fule moisture in forest.

  • PDF

A Study on the Response Characteristics Depending on Service Life of Ionization Smoke Detector (이온화식연기감지기의 사용기간에 따른 응답특성 연구)

  • Baek, Won-Don;Kim, Shi-Kuk;Ok, Kyung-Jea;Lee, Chun-Ha;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.61-64
    • /
    • 2008
  • This paper studied on the response characteristics depending on service life of ionization smoke detector. The experimental samples used ionization smoke detectors (360 EA) for over 5 years which were influenced by environment set up with fire objects. The experimental method performed operate and non-operate test according to 'Type Approval and Technical Regulation of Detector (KOFEIS 0301)', for estimate the response characteristics of ionization smoke detector depending on service life. The results showed that their response characteristics were rapidly decreasing when the longer their using period. Accordingly, it is desirable that ionization smoke detector has to be changed for early fire detection when passed their service life.

Spatio-Temporal Analysis of Forest Fire Occurrences during the Dry Season between 1990s and 2000s in South Korea (1990년대와 2000년대 건조계절의 산불발생 시공간 변화 분석)

  • Won, Myoung-Soo;Yoon, Suk-Hee;Koo, Kyo-Sang;Kim, Kyong-Ha
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.150-162
    • /
    • 2011
  • For the period between 1991 and 2009, the annual average of 448 forest fires occurred in Korea. Above all, approximately 94% of the total fires frequently occurred during the spring and fall seasons. Therefore, we need to minimize the damage of forest fire and manage them systematically. In this study, we analyzed the spatio-temporal distribution patterns for the frequency of forest fire occurrences by each city and gun during dry season between 1990s and 2000s using GIS. Then we compared to analyze the frequency of forest fire occurrence by ten-day intervals in 2000s with that in 1990s. As a result of analysis, early April showed the highest frequency of forest fire occurrence in both 1990s and 2000s. Compared to the 1990s and 2000s, the regional change of forest fire showed the most frequent fire events around Chungcheong province. Especially extra 27 fires increased in Daejeon city, and the second most frequent fire had more than 10 fires in Jeolla province and Incheon. However, the number of fire frequency decreased by 12 fires at the end of April in Hongcheon-gun(the province of Gangwon). This is the largest drop over the study period. We consider that this paper will utilize usefully to establish regional counterplan for forest fire prevention by understanding regional forest fire patterns from seasonal change.

A Study on Pore Pressure Evaluation of Concrete Lining in Road Tunnel Fire (도로터널 라이닝 화재조건 콘크리트 라이닝 공극압력 특성에 관한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Youl;Yoo, Yong-Ho;Lee, Chul-Ho;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.484-489
    • /
    • 2008
  • We carried out a one-way heating experiment on the PC panel manufactured by changing the filling depths(20,30,40,50mm) of concrete regarding the fire strength in order to measure the inner concrete pressure which is a direct cause of concrete spalling. This fire experiment was conducted under the fire strength conditions of ISO 834 Standard, Modified Hydrocarbon and the maximum value of Pore Pressure was measured. As a result of analyzing the time it took to reach maximum pressure, it showed that the time rising to the maximum pressure of high strength concrete of 40MPa is slower than that of a 24MPa tunnel lining. In case of ISO fire conditions, spalling damage might take place in heating period of $20{\sim}40$ minutes in the range of $100{\sim}200^{\circ}C$ temperature. In case of MHC fire conditions, the area damaged by fire can appear after a lapse of $25{\sim}50$ minutes in the range of $150{\sim}250^{\circ}C$ temperature.

  • PDF

The Active Measure of the Operation of the Volunteer Fire Brigade in Korea (우리나라 의용소방대의 활성화 방안 고찰)

  • Jeong, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.138-142
    • /
    • 2009
  • The system of The Volunteer Fire Brigade is the Civil autonomic one which was set up from The Chosun Dynasty and has been active. Having suffered from several dificulties from Japanese control in the Chosun Dynasty, The Volunteer Fire Brigade was established by the enactment 1958 Fire Law and we have had it up to this time. The Volunteer Fire brigade played an important role in the period of the past Fire fighting personnel and equipment which we did not have. It has carried out the assistance of the Fire extinction, the early extinction of a fire in the rural region, the extinction of the forest fire, and lots of social volunteering actions etc. but, today's Fire fighting system has made the surprising developments, such as the improvement of national economic power, the increase of knowledge about the safety of the people, the openness of The Fire Fighting Department of Korea. I will try to check out the role of The Volunteer Fire Brigade which filled up the lacking part the fire fighting in the past and make the measures which can activate in these days, looking for the new field of the movement.

Study on Cases of Priority Traffic Signal System for Emergency Vehicles: Based on a City's Pilot Operation Cases in Chungcheongbukdo Province (긴급차량 우선교통신호시스템 사례에 관한 연구: 충청북도 내 일개도시 시범운영 사례를 중심으로)

  • Kim, Jin-Hyeon;Lee, Hyo-Ju
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.121-126
    • /
    • 2020
  • The aim of this study is to suggest ways to capitalize on the golden period for timely response to fire and emergency victims. To implement a system to effectively capitalize on the golden period, there is a need for policy measures as well as legal and social consensus. Precedent research has relentlessly mentioned the need for and feasibility of the priority traffic system for emergency vehicles. To this end, the present study involved an analysis of pilot cases of the priority traffic signal system for emergency vehicles introduced in a city during 26 days, from April 3 to 28, 2017. Out of 58 cases registered with the local 1-1-9 fire house, the number of cases that took advantage of the priority traffic system stood at 16 in response to fire and 11 to first-aid operations. Owing to the system, on average, the response time reduced by 3 min and 50 s in case of fire and by 3 min and 30 s for first aid. There were four complaints registered owing to traffic congestion, and the number of car accidents declined to one from six over the same period in the previous year. Based on these findings, it is safe to say that the priority traffic signal system would be effective for emergency vehicles to capitalize on the golden period if issues identified during the pilot run are resolved.

Analysis of the Precautionary Measures and Causes on Explosion Accidents of a Old Dry Chemical Powder Extinguisher (노후 분말소화기의 폭발사고 원인과 예방대책에 관한 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.91-99
    • /
    • 2012
  • Fatal injuries and deaths have occurred resulting from the operation or disassembling of a powder extinguishers in Korea. If a rusted powder extinguisher is exploded during operation or disassembling, it rises to the air like a rocket and hits a head, chest, or neck part of an operator, resulting in his (her) death or injury. In this study examines the explosion accident cases of a powder fire extinguisher and analyzes their causes, reactions to explosion, and precautionary measures. And in this paper suggests 1) no using of old fire extinguishers in fire drill or education, 2) education and public information on danger of old fire extinguishers, 3) indication of explosion danger to cartridge-type dry chemical powder fire extinguishers had already placed to buildings etc., 4) obligatory indication of durable years on fire extinguishers, 5) examination for introduction of system that do hydraulic pressure test about fire extinguishers that given period past, 6) construction of system that reclaim old fire extinguishers, 7) construction of system that recycle or reuse old fire extinguishers, and 8) operation of help desk related to old fire extinguishers as precautionary measure of fire extinguisher explosion accidents.

Temperature and Flow Velocity Analysis for Fire in Synthetic Heat Transfer Fluid Boiler (열매유 보일러 내부화재에 따른 온도 및 속도분포 해석)

  • Kim, Yeob-Rae;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.19-25
    • /
    • 2013
  • The fire took place in the synthetic heat transfer fluid boiler. This study uses simulation to investigate the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is more or less unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120 kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The simulation shows that the temperature is $767^{\circ}C$ in the low part of the third pass. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. The temperature rises to $183^{\circ}C$ in the low part of the burner. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner.

Effect of Preventive and Prepared Fire Administration on Response Fire Administration (예방소방행정과 대비소방행정이 대응소방행정에 미치는 영향)

  • Lee, Wonjoo;Lim, Jae Hoon;Moon, Kwang Min
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.120-130
    • /
    • 2020
  • This study aimed to provide an empirical analysis of the effect of preventive fire administration (PVFA) and prepared fire administration (PPFA) on response fire administration (RPFA) in fire service organizations in Korea. To this end, panel data was collected from 16 metropolitan councils from the period of 2008 to 2018 and statistically analyzed using PVFA, PPFA, and RPFA. The independent variables were PVFA and PPFA, while the dependent variable was RPFA. The analysis of the current situation of the specific target for firefighting (STFF), public use facilities, proof of completion of safety families for public use facilities, and special fire inspection were sub-variables of PVFA. Fire safety education (FSE) and the mobilization for fire suppression (MFS) were sub-variables of PPFA and RPFA, respectively. In the results, STFF and FSE had a significant positive influence on the MFS. This study will contribute to the basic research regarding the investigation of the effectivity of fire service organizations in Korea.

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.